Страница 1: ...on clearances shown infigure1 Read Safety Instructions in Use Care book before using range CAUTION This rangehasbeendesignedin accordance withthe requirements of varioussafety Improper installation adjustment agenciesand complieswiththe maximum allowable alteration service maintenance or wood cabinettemperatures of 194 F If thisrange is installed withcabinets that havea lowerworking use of range c...

Страница 2: ...CH MAY BE ORDERED3o 76 2SEPERATELY cm THE OOUNTERTQP CUT OUT MUST REMAIN _ D A COUNTER SEE COUNTER HEIGHT NOTE 1 TOP C DEPTH CAB INE T _ _ OPEN ING FIGURE2 Notes 1 Providefor eithera 3 wireor4 wire1201208 1201240 voltoutletperapplicable cordinshadedareashown Refer to installation instructions for properpositioning of outlet 2 Dimension K figure3 page3 isfromthewalltothesideedgeoftheovendoor It doe...

Страница 3: ... JENN AIR RANGES 30 Unity IISlide In Range Dimensions J Inches Centimeters A 25 63 5 B 24 61 0 C 30 76 2 D 36 91 4 E 235 8 60 0 F 231 4 59 1 G 5 112 14 0 H 10 25 4 297 8 75 9 263 16 66 5 La 35314 90 8 M 2 114 5 7 _ SEE NOTES ON PAGE 2 3 ...

Страница 4: ...ionRequirements for Propane Constructionand Safety Standard Title 24 CFR Part Appliancesand Equipmentin R V s CSA Standard 3280 formerlythe Federal Standardfor MobileHome CAN CSA Z240 RV Series Construction and Safety Title 24 HUD Part 280 or whensuchstandardis notapplicable the Standardfor LOCATING THE RANGE Manufactured Home installations ANSI A225 1 NFPA Do notset rangeover holesinthe flooror o...

Страница 5: ... the marked EDGE fully inserted into and secured by the ANTI TIP toward center of opening and against the back wall as bracket Note A minimum clearance of 114 is shown in figure 5 required between the range and the leveling foot that C Use the bracket as a template and mark the required will engage the ANTI TIP bracket see figure 6 holes as shown in figure 5 for the type of construction B For safe...

Страница 6: ...ing for the range Remove terminal block access cover from range back is specified on the rating plate located on the front of the See figure 7 range RANGE CONNECTIONS Canada HOUSE WIRING This model wasshipped direct from the factory with Most localBuilding Regulationsand Codes requirethat all service cord pigtail attached There are no range electdcel wiringbe done by licensedelectricians All conne...

Страница 7: ... MAIN TERMINAL CONNECTION BLOCK or conduitconnect to the red and black postsof the BLACK_ _MIDDLE WIRE OF Y mainterminal block respectively SERVICE CORD OR GROUNO LEAD 4 An appropriate strain relief for servicecord or conduit or CONDU T must be attached to the conduit plate CONVERSION FROM 3 WIRE TO 4 WIRE GROUND _ _ _ 3 STAMPED Model With 3 Wire Service Cord Attached RELIF h_ _ _ f _ _Sl on back ...

Страница 8: ...ts MOTORSI DE A R INLET SIDE 5 Remove nuts from studs 5 6 7 and 8 on inlet f __ _ ___ _ side 6 Remove bracket and reattach with studs 8 and 5 inserted in holes D and B and replace all 4 nuts 5 Attach the blower housing to the floor with the outlet towards the direction of the venting and the inlet towards the front of the cabinets In addition for left Figure 16 side venting a spacer of approximate...

Страница 9: ...ge to itsdesignated location andslide S Connect theblower power cordtotheblower motor backintoposition Makesurethattherearleveling leg housing is fullyinsertedandsecuredbythe anti tipbracket BLOWER POWERCORO S Attachtheotherendoftheflexducttothe plenum of therangeusing thesecond ductclamp Tighten duct clampto secureittothe plenum CHECK FOR OPERATION S Install theairfilter As youfacetherange thetop...

Страница 10: ...orto LP inserta coin intothe slotin the pipingsystem by closingits individualmanualshutoff cap of the regulatorand turncounterclockwise to loosen valveduringany pressuretestingof the gas supplypiping Reverse invert cap push downandturn clockwiseto system at test pressuresequal to or lessthan 1 2 PSIG lock in place When finished the marking LP shouldbe 3 5 k Pa visibleinthe centerwell of the cap AP...

Страница 11: ...aturalgas to LP applya 1 2 open endedwrenchto hex snugfit of the airshutterassuresit willremain positioned sectionof orifice hood TURN COUNTERCLOCKWISE correctly TO REMOVE Save the NaturalGas orificehoodsjust removedfrom thisapplianceforfuture use Installcolor coded orificehoodssupplied SEE GAS CONVERSION INSTRUCTIONS PAGE 14 TURN CLOCKWISE TO INSTALL Holddimensionspec fiad n llustrat on B CONTROL...

Страница 12: ...DS OF A CLOTH DISHTOWEL UNDER THE KNOB AND PULL THE VALV TOWEL UPWARD WITH STEADY EVEN STEM_ PRESSURE 3 Insert a slender thin blade screwdriver into the recess at center of valve stem and engage blade with slot in adjusting screw ILLUSTRATION D 4 Turn center stem adjusting screw to set flame size clockwise to reduce counterclockwise to increase 5 Replace control knob when adjustment is completed P...

Страница 13: ...ater Column Incoming Propane Gas pressure required to regulator 11 14 Water Column Propane Gas conversion Orifice Hoods are supplied with these models PROPANECONVERSION INCHES BURNER BTU hr ORIFICE DIAMETER COLOR Left Rear LR 8 000 67 032 Green Left Front LF 8 000 67 032 Green RightRear RR 9 000 66 033 Zinc RightFront RF 9 000 66 033 Zinc 14 ...

Страница 14: ...vert cap in pressure regulator see illustration A With the appliance installed the regulator Is located on the center underside of the appliance at the inlet to the gas manifold Identify the type of regulator on the unit and follow the instructions in the appropriate illustration Manifold Natural Gas pressure required 5 Water 3 Adjust low flame setting for each burner Follow the Column instruction...

Страница 15: ...spray with commercial oven cleaner Follow 4 Slide range forward to disengage range from the manufacturer s directions anti tip bracket See page 5 Clean gas ports with a straight pin especially the port 5 Reverse procedure to reinstall If gas line has been below the ignitor Do not enlarge or distort holes disconnected check for gas leaks after reconnection Be careful not to get water into burner po...