Whirlpool GZ5730XR Series Скачать руководство пользователя страница 11

11

ASSISTANCE OR SERVICE

When calling for assistance or service, please know the purchase 
date and the complete model and serial number of your 
appliance. This information will help us to better respond to your 
request.

If you need replacement parts

If you need to order replacement parts, we recommend that you 
use only factory specified parts. Factory specified parts will fit 
right and work right because they are made with the same 
precision used to build every new appliance. To locate factory 
specified replacement parts in your area, call us or your nearest 
designated service center.

In the U.S.A.

Call the Whirlpool Customer eXperience Center 
toll free: 1-800-253-1301.

Our consultants provide assistance with:

Features and specifications on our full line of appliances.

Installation information.

Use and maintenance procedures.

Accessory and repair parts sales.

Specialized customer assistance (Spanish speaking, hearing 
impaired, limited vision, etc.).

Referrals to local dealers, repair parts distributors and service 
companies. Whirlpool designated service technicians are 
trained to fulfill the product warranty and provide after-
warranty service, anywhere in the United States.

To locate the Whirlpool designated service company in your 
area, you can also look in your telephone directory Yellow 
Pages.

For further assistance

If you need further assistance, you can write to Whirlpool 
Corporation with any questions or concerns at:

Whirlpool Brand Home Appliances
Customer eXperience Center
553 Benson Road
Benton Harbor, MI 49022-2692

Please include a daytime phone number in your correspondence.

In Canada

Call the Whirlpool Canada LP Customer eXperience Centre toll 
free: 1-800-807-6777.

Our consultants provide assistance with:

Features and specifications on our full line of appliances.

Use and maintenance procedures.

Accessory and repair parts sales.

Referrals to local dealers, repair parts distributors, and 
service companies. Whirlpool Canada LP designated service 
technicians are trained to fulfill the product warranty and 
provide after-warranty service, anywhere in Canada. 

For further assistance

If you need further assistance, you can write to Whirlpool 
Canada LP with any questions or concerns at:

Customer eXperience Centre
Whirlpool Canada LP
1901 Minnesota Court
Mississauga, Ontario L5N 3A7

Please include a daytime phone number in your correspondence.

Содержание GZ5730XR Series

Страница 1: ...T 36 91 4 CM Instructionsd installationetGuided utilisationetd entretien Table of Contents Table des matières 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT GZ5730XR Series GZ5736XR Series Série GZ5730XR Série GZ5736XR 9763367B ...

Страница 2: ...on de la hotte 21 Achever l installation 21 UTILISATION DE LA HOTTE 21 Fonctionnement 21 ENTRETIEN DE LA HOTTE 21 Nettoyage et entretien 21 ASSISTANCE OU SERVICE 22 GARANTIE 23 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to red...

Страница 3: ...and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowl...

Страница 4: ...HOODPT3 must be used Product Dimensions ElectricalRequirements IMPORTANT The hood must be electrically grounded in accordance with local codes and ordinances and with National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A...

Страница 5: ...tructions in the Make Electrical Connection section Calculating Vent System Length To calculate the length of the system you need add the equivalent feet meters for each vent piece used in the system Use 3 x 10 8 3 cm x 25 4 cm or 7 17 8 cm round vent with a maximum length of 65 ft 19 8 m for vent system For best performance use no more than three 90 elbows To calculate the length of system you ne...

Страница 6: ...d installations Cut the vent system and electrical wiring access holes as required If wiring through the top use location shown in vertical vent system If wiring through the back use location shown in horizontal vent system 3 x 10 8 3 x 25 4 cm rectangular vertical vent system Vent Piece 7 17 8 cm Round 45 elbow 2 5 ft 0 8 m 90 elbow 5 0 ft 1 5 m 7 17 8 cm wall cap 0 0 ft 0 0 m 3 x 10 8 3 cm x 25 ...

Страница 7: ... 5 Depending on your installation remove either top or back wiring knockout and install a UL or CSA listed strain relief For non vented installations Go to Make Electrical Connection section For vented installations 1 Remove the five screws holding the light panel in place and set them aside 2 Disconnect the light assembly wiring connector Make sure not to disconnect any wires 3 Remove the light p...

Страница 8: ...ape from damper flap NOTE For horizontal vent systems it is recommended that the rectangular ventwork be attached to the damper vent connector and sealed with vent clamps before installing the hood Round vent only Replace round vent plate removed in step 1 of Prepare the Hood section Install a 7 17 8 cm round damper must be purchased separately The damper flap must open freely in the direction on ...

Страница 9: ...ve screw heads about 6 4 mm away from shim strips 2 Lift range hood into final position feeding electrical wire through wiring opening To avoid damage do not push on fan blade 3 Position the range hood so the that large end of the keyhole slots are over the screws Then push the hood toward the wall so that the screws are in the neck of the slots WARNING Electrical Shock Hazard Disconnect power bef...

Страница 10: ...Before you begin make sure that the range hood is turned off and that the lamps have had sufficient time to cool Halogen bulbs burn extremely hot See bulb packaging for further information Replace with 2 PAR20 50W maximum halogen bulbs or 2 R16 40W maximum incandescent bulbs RANGE HOOD CARE CleaningandMaintenance Be sure lights are cool before cleaning the range hood To clean range hood 1 Disconne...

Страница 11: ...to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the Whirlpool designated service company in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience C...

Страница 12: ...ice by an authorized Whirlpool servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 11 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined This warranty is void if the factory applied s...

Страница 13: ...as de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiel...

Страница 14: ... extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINIÈRE Ne jamais laisser un élément de surface fonctionner à puissance de chauffage max...

Страница 15: ...ment Pour les installations raccordées à un cordon électrique une trousse de raccordement au cordon électrique de la hotte de cuisinière homologué UL pièce n HOODPT3 doit être utilisé Dimensions du produit Spécificationsélectriques IMPORTANT La hotte doit être correctement mise à la terre conformément aux codes et règlements locaux en vigueur et au National Electrical Code aux normes ANSI NFPA 70 ...

Страница 16: ...é autour de la bouche de décharge à l extérieur à travers le mur ou le toit Méthodes d évacuation Déterminer la méthode à utiliser pour la décharge à l extérieur Il est recommandé que l installation du circuit d évacuation soit réalisée avant celle de la hotte REMARQUE Si l on souhaite une installation sans décharge à l extérieur recirculation suivre les instructions de la section Raccordement éle...

Страница 17: ...ctionner les schémas ci dessous correspondant à la configuration de l installation Installations avec décharge à l extérieur Découper selon le besoin les trous de passage du câble électrique et du conduit d évacuation Longueur maximale recommandée 35 pi 10 7 m 1 coude à 90 5 0 pi 1 5 m section droite de 8 pi 2 4 m 8 pi 2 4 m 1 bouche de décharge murale 0 pi 0 m Longueur du système de 3 x 10 8 3 cm...

Страница 18: ...res et les conserver à part 3 Retirer de la hotte le module clapet connecteur du conduit Conserver à part le connecteur les vis de montage et le sachet de pièces 4 À l intérieur de la hotte enlever le couvercle du boîtier de raccordement Conserver à part le couvercle et les vis de montage 5 Enlever l opercule arrachable du trou de passage de câble approprié dessus ou arrière selon la configuration...

Страница 19: ...s de la hotte 7 Réinstaller le diffuseur d air 8 Rebrancher le connecteur de câblage du luminaire et réinstaller le panneau du luminaire REMARQUE Veiller à ne pas coincer les conducteurs entre le support et le panneau du luminaire 9 Enlever l opercule arrachable rectangulaire du dessus ou de l arrière Si l air doit être évacué par un conduit rond de 7 17 8 cm enlever l opercule arrachable rectangu...

Страница 20: ... par câblage direct 1 Déconnecter la source de courant électrique 2 Si cela n a pas déjà été fait faire passer le câble d alimentation à travers le mur ou les placards installer le câble conformément aux codes et règlements en vigueur 3 Placer la hotte comme on le voit sur l illustration Faire passer le câble d alimentation électrique à travers le serre câble 4 Connecter ensemble les conducteurs n...

Страница 21: ...ace de cuisson Les pales du ventilateur doivent tourner librement 3 Reconnecter la source de courant électrique 4 Contrôler le fonctionnement correct de l appareil UTILISATION DE LA HOTTE Fonctionnement Tableau de commande de la hotte Fonctionnement du ventilateur Le ventilateur est commandé par un commutateur à bascule à 3 positions Lorsqu on pousse le bouton vers la gauche on sélectionne la bass...

Страница 22: ...ol sans frais d interurbain au 1 800 253 1301 Nos consultants sont prêts à vous aider pour les questions suivantes Caractéristiques et spécifications sur toute notre gamme d appareils électroménagers Renseignements d installation Procédés d utilisation et d entretien Vente de pièces de rechange et d accessoires Assistance spécialisée aux consommateurs langue espagnole malentendants malvoyants etc ...

Страница 23: ...Whirlpool autorisé n est pas disponible 10 La dépose et la réinstallation de votre gros appareil si celui ci est installé dans un endroit inaccessible ou n est pas installé conformément aux instructions d installation fournies 11 Les gros appareils ménagers dont les numéros de série et de modèle originaux ont été enlevés modifiés ou qui ne peuvent pas être facilement identifiés La présente garanti...

Страница 24: ...9763367B 2008 All rights reserved Tous droits réservés 9 08 Printed in Italy Imprimé en Italie ...

Отзывы: