PRODUCT MODEL NUMBERS

GXW6530DX

GXW6536DX

ELECTRICAL REQUIREMENTS

• A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

VENTING REQUIREMENTS

This canopy hood is factory set for venting through the roof or wall.
A 6" (15.2 cm) round vent system is needed for installation (not included). The
hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and
air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a
wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter and
the deflector. Fumes and vapors are recycled through the top grille.

30" and 36" (76.2 cm and 91.4 cm) Wall-Mount 
Canopy Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10292167C

10/26/10

®

A

A

B

B

B

A

Roof Venting

Wall Venting

Non-vented 

(recirculating)

A. Roof cap
B. 6" (15.2 cm) 

round vent

A. Wall cap
B. 6" (15.2 cm) 

round vent

A. Deflector
B. 6" (15.2 cm) 

round vent

20"

(50.8 cm)

30" (76.2 cm) or
36" (91.4 cm)

13

³⁄₁₆

"

(33.5 cm)

10

⁷⁄₈

"

(27.6 cm)

Page 1 of 2

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.

Vent Piece

Round

45° elbow

2.5 ft (0.8 m)

90° elbow

5.0 ft (1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

PRODUCT DIMENSIONS

Example vent system

The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).

1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight

= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)

Length of system

= 13.0 ft (3.9 m)

90  elbow

6 ft (1.8 m)

2 ft

(0.6 m)

Wall cap

*For non-vented (recirculating) installations

**For vented installations

17

³⁄₁₆

" (43.7 cm)

**27

¹⁄₈

" (68.9 cm) min.

**41

¹⁄₈

" (104.5 cm) max.

*27

¹⁄₈

" (68.9 cm) min.

*45

¹⁄₂

" (115.6 cm) max.