Страница 1: ... and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You c...

Страница 2: ...e injury or death foRow all installation instructions Save these instructions XNSTALLATXON REQUIREMENTS TOOLS AND PARTS Gather the required tools and parts before starting installation Tools needed Tape measure Pliers G Flat blade screwdriver Wire stripper direct wire installations 1 4 nut driver recommended Adjustable wrench that opens to 1 25mm or hex head socket wrench 2 2 Phillips screwdriver ...

Страница 3: ...m hardware available for purchase from your dealer For further information see Assistance or Service section in your Use and Care Guide Special provisions must be made in mobile homes to introduce outside air into dryer Openings such as a nearby window should be at least twice as large as dryer exhaust opening LOCATION REQU REMENWS DRYER DiMENSiONS Front view 27 686 mm 35 3 8 899 mm Side view Left...

Страница 4: ... may not tumble properly and automatic sensor cycles may not operate correctly For each arrangement consider allowing more space for ease of installation and servicing spacing for companion appliances and clearances for walls doors and floor moldings Space must be large enough to allow door to fully open Add spacing on all sides of dryer to reduce noise transfer If a closet door or Iouvered door i...

Страница 5: ...ctors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed strain relief if your o...

Страница 6: ...ed to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock Remove screws from 3 4 19 mm UL listed strain relief UL marking on strain relief Put two clamp section tabs into hole below terminal block opening with one tab pointing up and one pointing down Hold in ...

Страница 7: ...m UL listed strain relief UL marking on strain relief Put threaded section of strain relief through hole below terminal block opening screw removable conduit connector onto strain relief threads 6 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Follow steps 7 10 Then go to Venting Requirements Power supply cord 3 wire receptacle NEMA Type 10 30R Follow steps ...

Страница 8: ...w go to Venting Requirements 3oWIRE FOWER UFFLY CORD CONNECTION Choose a standard power supply cord connector Connect neutral ground wire and neutral wire Connect neutral ground wire and neutral wire white or center wire of power supply cord under center silver colored terminal block screw Tighten screw 9 Connect ground wire Connect ground wire green or bare of power supply cord to external ground...

Страница 9: ...ueeze hooked end together and tighten screw 15 Connect neutral ground wire and neutral wire Connect neutral ground wire and place hooked end hook facing right of neutral wire white or center wire of direct wire cable under center screw of terminal block Squeeze hooked ends together and tighten screw 16 Connect ground wire i Connect ground wire green or bare of direct wire cable to external ground ...

Страница 10: ...ect wire cable under center terminal block screw Squeeze hooked end together Tighten screw Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements OPTION_ 3oWIR...

Страница 11: ...astic or metal foil vent Rigid metal vent Recommended for best drying performance and to prevent crushing and kinking Flexible metal vent Acceptable only if accessible to clean Must be fully extended and supported in final dryer location Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install in enclosed walls ceilings or floors The total l...

Страница 12: ... from your dealer or by calling Whirlpool Service For more information see Assistance or Service section in your Use and Care Guide Optional exhaust installations Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire If you prefer dryer may be converted to exhaust out right side left side or throug...

Страница 13: ...Number of 90 elbows 0 1 2 3 4 Vent system chart Angled hoods 58 ft 17 7 m 48 ft 14 6 m 38 ft 11 6 m 29 ft 8 8 m 21 ft 6 4 m Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box Iouvered hoods 64 ft 20 m 54 ft 16 5 m 44 ft 13 4 m 35 ft 10 7 m 27 ft 8 2 m XNS L _NT SYSTEM 25 Install exhaust hood 12 rain ram 12 rnin 305 turn Install exhaust hood and use caulking compound to se...

Страница 14: ...t outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp Place level here Check levelness of dryer from side to side Repeat from front to back Not Level LEVEL Not Level 32 Tighten and adjust leveling legs If dryer is not level prop up using a wood block use wrench to adjust legs up or down and check again for levelness Once legs are level make sure all four...

Страница 15: ...cle interrupted by power failure Press and hold START to restart dryer Try the following Check if a household fuse has blown or circuit breaker has tripped Electric dryers use two household fuses or breakers Replace fuse or reset circuit breaker Confirm power cord is properly installed Refer to Electrical Connection section for details Select a Timed Dry heated cycle and restart dryer If message p...

Страница 16: ...W10240579A W10240583A SP 2009 All rights reserved 6 09 Printed in U S A ...