2-5
3-WIRE POWER SUPPLY
CORD CONNECTION
IMPORTANT:
Use this procedure only where
local codes permit connecting a cabinet-ground
conductor to the neutral wire.
1.
Remove the terminal block cover hold-
down screw and open the cover at the
back of the dryer.
2.
Remove the center terminal block screw.
3.
Connect the neutral wire (white or center
wire) of the power supply cord to the
center, silver terminal block screw.
A. External ground connector
B. Neutral grounding wire (green/yellow)
C. Center, silver terminal block screw
D. Neutral wire (white or center wire)
E. 3/4
″
(1.9 cm) UL-listed strain relief
A
B
C
D
E
4.
Connect the ends of the remaining power
supply wires to the left and right terminal
block screws.
L
R
5.
Check the wire connections and make
sure that they are all tight.
6.
Tighten the strain relief clamp screws.
7.
Insert the tab of the terminal block cover
into the slot of the dryer rear panel and
secure the cover with its mounting screw.