8
To locate a distributor near you, please visit www.coinop.com/distributor, or call 1–800–NO–BELTS.
COMMERCIAL DRYER SPECIFICATIONS
2.2"
(5.6 cm)
4.75"
(12.1 cm)
18.385
(46.7 cm)
1.25"
(3.2 cm)
.75"
(12.1 cm)
27.25"
(69.2 cm)
27.75" (70.5 cm)
25.50" (64.8 cm)
7.87"
(20 cm)
Exhaust Information
All dryers require the equivalent of a 4-inch
diameter exhaust duct. Rigid metal duct is
recommended. Failure to properly exhaust
the dryer will result in improper operation.
Dimensions are for planning purposes only. For complete information,
see installation instructions packed with product.
# of 90°
Turns
4" Hood
2
1
⁄
2
" Hood
Maximum Length of 4" Diameter Rigid metal Duct
0
64 Ft.
58 Ft.
1
54 Ft.
48 Ft.
2
44 Ft.
38 Ft.
3
35 Ft.
29 Ft.
4
27 Ft.
21 Ft.
Maximum Length of 4" Diameter Rigid metal Duct
0
36 Ft.
28 Ft.
1
31 Ft.
23 Ft.
2
27 Ft.
19 Ft.
3
25 Ft.
17 Ft.
4
23 Ft.
15 Ft.
SINGLE DRYER SPECIFICATIONS
MODEL NUMBER
CEM2940TQ
††
CGM2941TQ
†
GENERAL INFORMATION
Stainless steel look Push Button console, white
enamel drum, powdered paint finish cabinet and
top, removable lint filter, improved meter case.
Metercase Model Factory Installed
Coin Slide and Coin Box,
$1.00 Factory Preset
$0–2 per Cycle,
Metercase Model Factory Installed
Coin Slide and Coin Box,
$1.00 Factory Preset
$0–2 per Cycle,
ELECTRICAL REQUIREMENTS
3-Wire Nominal 240/208V, 60 Hz., A.C.
Standard 30-amp Breaker/Fuse Branch
Circuit per Dryer (subject to local codes)
Nominal, 120V, 60Hz., A.C., Standard 15-amp
Breaker/Fuse Branch Circuit per
Dryer (subject to local codes)
MOTOR
1
⁄
3
HP Single Speed Motor with Built-In
Overload Protector 5.9-amps Max Rating
1
⁄
3
HP Single Speed Motor with Built-In
Overload Protector 5.9-amps Max Rating
HEATER TYPE
ELECTRIC
GAS
**
HEATER/BURNER RATING
(Add 500 watts approx for motor on all
dryer models)
Heater Rated at 5600 Watts
22,000 BTUh
Natural Gas
OPERATIONAL AMPERAGE
(Does not include control or gas valve)
Motor —4.0-amps
No load
Heater—23.33-amps@240V 27.33 Total
Motor —4.0-amps
No load
DIMENSIONS
See Illustrations
42.875"H*, 29"W, 27.75"D
42.875"H*, 29"W, 27.75"D
SHIPPING WEIGHT (EST.)
147 Lbs.
147 Lbs.
DRUM VOLUME
7.0 Cu. Ft.
7.0 Cu. Ft.
*(height at meter case top) **Burner orifices are available for manufactured, natural, mixed, and LP gas with varying BTU ratings.
†
LP Conversion Kit: 49572
††
Power cords on electric models sold separately Energy information is available online at www.coinop.com/products. WP lit# CWXL077