Whirlpool AWT 2284 Скачать руководство пользователя страница 3

S E R V I C E

Whirlpool Europe

AWT 2284

21.05.2001 / Page 3

Customer Service

8561 228 10140

Doc. No: 4812 712 16287

Technical data

Program timer

Type

Electromechanical

Fab.

EC 4774 (Timer A2-)

Nominal voltage

230

V

Frequency

50

Hz

Total positions

60

Pre wash

pos.

01

Main wash

pos.

06

Rinse

pos.

21

Spin

pos.

33/ 58

Stop

pos.

37/ 60

Ambient temperature to

70

˚C

Storage temperature to

85

˚C

Motor

Type

MCA 30/64 - 148/ALA 1
i = 1 : 17.3

Pulley diameter

16.5

mm

Resistance: Contact 6 - 7 68.7

Ω ±

  7%

Collector directly 4 - 5

3.07

Ω ±

  7%

Field winding 2 - 3

2.40

Ω ±

  7%

Tacho
(at 825 rpm on motor)

1 - 2

V

Tacho pole pairs

16

Protector, current sensitive 150

˚C

Sense of rotation in spinning,
in view on pulley side

clockwise

Radio interference supression

Nominal voltage

230

V

Nominal capacity

470 nFX1+2 x22 nFY

Nominal inductance

2 x 0.5

mH

Nominal resistance

680

k

Thermostats

- optional

Thermostat Bi-metal 60˚C

ON

40

±

  4

˚C

OFF

55

±

  3

˚C

Rated voltage

230

V

Rated current

10

A

Thermostat variable

Nominal voltage

230

V

Nominal current

10

A

Temperature range

28 (

±

  4) - 80 (

±

  3) ˚C

Spin speed selector switch

Positons

7

Switch mains

Push button On/Off

SM

Push button switch

Eco

SEC

Half load

SHL

Rinse hold

SRS

Motor electronic 800 rpm

Type

RN 2239

Содержание AWT 2284

Страница 1: ...rt list 4 Exploded view 5 6 Wiring diagram 7 Circuit diagram 8 Program diagram 9 Service Manual Washing machine Toploader AWT 2284 AWT 2284 This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 21 05 2001 Subject to modification Document No 4812 712 16287 ...

Страница 2: ...Switching point 50 5 mmWc Overflow Switching point 285 20 mmWc Nominal current Contacts 11 12 0 5 1 mA 5 V DC 11 14 0 5 1 mA 5 V DC 21 12 4 4 A 21 24 16 4 A 21 26 1 1 A Contactsystem 11 12 14 jump contacts 21 22 24 jump contacts 21 26 slow action contacts Door lock Lock time 0 85 C 5 Unlock time after 30 on 110 50 Nominal voltage 250 V Nominal current contacts 4 5 16 4 A Heating element Kind of he...

Страница 3: ... 3 07 Ω 7 Field winding 2 3 2 40 Ω 7 Tacho at 825 rpm on motor 1 2 V Tacho pole pairs 16 Protector current sensitive150 C Sense of rotation in spinning in view on pulley side clockwise Radio interference supression Nominal voltage 230 V Nominal capacity 470 nFX1 2 x22 nFY Nominal inductance 2 x 0 5 mH Nominal resistance 680 kΩ Thermostats optional Thermostat Bi metal 60 C ON 40 4 C OFF 55 3 C Rate...

Страница 4: ...90 0 4812 321 18066 Cable mains EU 2m 490 1 4812 321 28367 Strain relief 500 0 4812 282 18856 Timer EC4774 521 0 4812 214 78455 Control unit RN2239 A2 552 0 4812 282 48235 Thermostat monopack 60 C 554 0 4812 282 48234 Thermostat variable Pos No 12NC Code Description 571 0 4812 281 28393 Valve magnet 571 1 4812 281 18049 Cover f valve 581 0 4812 271 28396 Pressostat 620 0 4819 410 29005 Switch Opti...

Страница 5: ...S E R V I C E Whirlpool Europe AWT 2284 21 05 2001 Page 5 Customer Service 8561 228 10140 Doc No 4812 712 16287 Exploded view ...

Страница 6: ...S E R V I C E 21 05 2001 Page 6 AWT 2284 Whirlpool Europe Doc No 4812 712 16287 8561 228 10140 Customer Service Exploded view ...

Страница 7: ...S E R V I C E Whirlpool Europe AWT 2284 21 05 2001 Page 7 Customer Service 8561 228 10140 Doc No 4812 712 16287 Wiring diagram ...

Страница 8: ...S E R V I C E 21 05 2001 Page 8 AWT 2284 Whirlpool Europe Doc No 4812 712 16287 8561 228 10140 Customer Service Circuit diagram ...

Страница 9: ...S E R V I C E Whirlpool Europe AWT 2284 21 05 2001 Page 9 Customer Service 8561 228 10140 Doc No 4812 712 16287 Program diagram ...

Отзывы: