background image

GB9

The following instructions, given in numerical order, refer to the figures on the last pages of this manual.

Note:

Some instructions differ according to the hood body width and height, in which case installation differences are given in the text and in the figures.

1.

Pull the panel (FRONT) firmly downwards.

2.

Push the small lever (located in the right part of the panel) to the left.

3.

Release it from the rear supports.

4.

Mark a line on the wall up to the ceiling, corresponding to the centre line.

5.

Cut the template at the line 

H6

and place the drilling diagram on the wall (fix it with adhesive tape): the vertical centre line printed on the drilling diagram

must match the centre line drawn on the wall, and the lower edge of the drilling diagram must match the lower edge of the hood.

Drill a hole.

6.

Remove the drilling diagram and insert plugs and screws as shown.

7.

Partially tighten the screws

8.

Place the flue support bracket on the wall and against the ceiling. Drill and insert the wall plugs as shown. Fix the bracket.

9.

For Extractor Version only

- rear exhaust outlet: Make a hole in the rear wall for the exhaust pipe.

10.

For Extractor Version only

- ceiling exhaust outlet: Make a hole in the ceiling for the exhaust pipe.

11.

Prepare the connection to the household electrical system.

12.

For Filter Version only:

Fix the deflector to the flue support bracket.

13.

Remove the tape holding the control electronics box to the motor body.

Note:

The figure is only a guide, and the box may be temporarily fixed to other sides of the motor body.

14.

Remove the grease filter(s) (one or more filters, depending on the model).

15.

Hook the hood to the wall.

16.

Adjust the hood horizontally.

17.

Adjust the distance between the hood and wall.

18.

Mark the hole(s) for final fixing of the hood as shown.

19.

Remove the hood from the wall.

20.

Drill and insert wall plugs as shown.

21.

Rehook the hood on the wall.

22.

Fix the hood to the wall with screws as shown.

23.

Fix the collar to the exhaust outlet hole.

24.

Secure the box with the screws already pre-tightened to the motor body.

Note: 

The box is of two types, with front fixing or rear fixing. Follow the instructions in the figures (

24a

and 

24b

) depending on your model.

25.

Fit the power cable in the special housing.

26.

Secure the cable to the cable clamp.

IMPORTANT: This operation is compulsory, and is to prevent accidental disconnection of the power cable.

Carry out the connection to the household electrical system.

27.

Connect the fume exhaust pipe to the collar; the pipe must be run towards the outside (

extractor version

) or towards the deflector (

filter version

).

28.

Fit the flues over the extraction unit, in the special seat above the hood.

29.

Pull out the top section and fix the flues with the screws as shown.

30.

Install the carbon filter (

Filter Version only

) andrefit the grease filter(s) (one or more filters, depending on the model).

31.

Hook the panel to the hood.

32.

Secure the panel with the special lever located on the right of the panel.

Note:

Make sure the panel is properly secured in place.

33.

Turn the panel covering the extraction area, hooking it to the hood by pressing hard.

IMPORTANT: Always check that the panel is firmly fixed in place.

Check correct hood operation, referring to the hood description and use section.

INSTALLATION - ASSEMBLY INSTRUCTIONS

Содержание AKR 995/1

Страница 1: ...User and maintenance manual GB ...

Страница 2: ......

Страница 3: ...for class II hoods identified by the symbol on the specifications label The power supply cable must be long enough to permit connecting the appliance to the mains socket outlet Do not pull the power supply cable in order to unplug the appliance The electrical components must no longer be accessible to the user after installation Do not touch the appliance with any wet part of the body and do not o...

Страница 4: ...ions for cleaning the hood and replacing the filters may result in a fire The fume extractor hood must never be opened without the grease filters installed and it should be kept under constant supervision Gas appliances must be used under the extractor hood only with pans resting When using more than three gas cooking points the hood should be operating at power level 2 or greater This will elimin...

Страница 5: ... the recycle symbol The various parts of the packing must therefore be disposed of responsibly and in full compliance with local authority regulations governing waste disposal Scrapping the product This appliance is marked in compliance with European Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE By ensuring this product is disposed of correctly you will help prevent potential...

Страница 6: ...service number number after the word Service on the rating plate located on the inside of the appliance The service number is also indicated on the guarantee booklet Your full address Your telephone number If any repairs are required please contact an authorised After sales Service to guarantee that original spare parts will be used and repairs carried out correctly TROUBLESHOOTING GUIDE AFTER SAL...

Страница 7: ...mp cover off 3 Remove the burnt out lamp and fit a new one CAUTION MAINTENANCE 4 Replace the lamp cover so that it clicks into position ACTIVE CARBON FILTER The carbon filter must be cleaned once a month in a dishwasher at the highest temperature using a normal dishwasher detergent Wash the filters on their own After washing reactivate the carbon filter by drying it in the oven at 100 C for 10 min...

Страница 8: ...bon filter s order one them and fit it them before use Install the hood away from very dirty locations windows doors and sources of heat The hood comes supplied with all the materials required for installation on most walls ceilings However a qualified technician is needed to make sure that the plugs are suitable for your ceiling Side wall units Side wall units centre line 65 cm gas or combi cooke...

Страница 9: ...move the grease filter s one or more filters depending on the model 15 Hook the hood to the wall 16 Adjust the hood horizontally 17 Adjust the distance between the hood and wall 18 Mark the hole s for final fixing of the hood as shown 19 Remove the hood from the wall 20 Drill and insert wall plugs as shown 21 Rehook the hood on the wall 22 Fix the hood to the wall with screws as shown 23 Fix the c...

Страница 10: ... suction USING THE HOOD Disconnect the appliance from the power supply Perimeter extraction panel cleaning Removal Pull the panel FRONT firmly downwards Cleaning The extraction panel must be cleaned as often as the grease filter using a rag moistened with neutral liquid detergent Do not use products containing abrasives DO NOT USE ALCOHOL Fitting The panel must be fixed at the front in the special...

Страница 11: ...4 5 1 3 2 ...

Страница 12: ...6 8 7 ...

Страница 13: ...220 240 V 50 60 Hz 9 10 11 12 13 14 ...

Страница 14: ...15 16 17 19 20 21 18 ...

Страница 15: ...22 23 24a 25a 24b 25b ...

Страница 16: ...26 27 29 30 28 ...

Страница 17: ...31 33 32 ...

Страница 18: ......

Страница 19: ...400011170718 GB Printed in Italy 08 2017 ...

Отзывы: