Whirlpool AKR 551 JA Скачать руководство пользователя страница 5

GB3

GB3

After unpacking the appliance, check for any transport damage. In the event of problems, contact the dealer or your nearest After-sales Service. To prevent any
damage, only remove the appliance from its polystyrene foam packaging at the time of installation.

PREPARING FOR INSTALLATION

this is a heavy product; the hood should only be lifted and installed by two or more people.

The minimum distance between the support of the cooking pans on top of the cooker and the bottom of the hood must not be less than 50 cm for electric
cookers and 65 cm for gas or mixed cookers. Before installation also check the minimum distances stated in the manual of the cooker.
If the installation instructions for the cooker specify a greater distance between cooker and hood, this distance must be observed.

ELECTRICAL CONNECTION

Make sure the power voltage specified on the appliance rating plate is the same as the mains voltage.
This information may be found on the inside of the hood, under the grease filter.
Power cable replacement (type H05 VV-F 3 x 0,75 mm²) must be carried out by a qualified electrician. Contact an authorized service centre.
If the hood is fitted with an electric plug, connect the plug to a socket complying with current regulations, located in an accessible place after installation. If no
plug is fitted (direct wiring to the mains), or if the socket is not located in an accessible place, install a standardised double pole power switch that will enable
complete isolation from the mains in case of category III overvoltage conditions, in accordance with installation rules.

If the cable is not fitted with a plug, connect the wires according to the following table:

WARNING:

INSTALLATION

Declaration of conformity 

• This appliance has been designed, manufactured and marketed in compliance with: 
- safety objectives of the “Low Voltage” Directive 2014/35/EU; 
- the ecodesign requirements of european regulations n. 66/2014, n. 327/2011, n. 244/2009, n. 245/2009, n.1194/2012, n. 2015/1428;
- the protection requirements of Directive “EMC” 2014/30/EU.
Electrical safety of the appliance can only be guaranteed if it is correctly connected to an approved earthing system.   

Energy saving tips

• Switch ON the hood at minimum speed when you start cooking and kept it running for few minutes after cooking is finished.
• Increase the speed only in case of large amount of smoke and vapour and use boost speed(s) only in extreme situations. 
• Replace the charcoal filter(s) when necessary to maintain a good odour reduction efficiency. 
• Clean the grease filter(s) when necessary to maintain a good grease filter efficiency.
• Use the maximum diameter of the ducting system indicated in this manual to optimize efficiency and minimize noise.

AIR VENT (for the suction versions)

Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.

!

Use a duct of the minimum indispensible length.

!

Use a duct with as few elbows as possible (maximum elbow angle: 90°).

!

Avoid drastic changes in the duct cross-section.

!

The company declines any responsibility whenever these regulations are not respected.

Mains voltage and frequency

Wire connection

220-240 V  
50/60Hz 

: yellow/green

N

: blue

L

: brown

Содержание AKR 551 JA

Страница 1: ...User and maintenance manual GB ...

Страница 2: ......

Страница 3: ...isconnected from the power supply before carrying out any installation work Earthing of the appliance is compulsory Not necessary for class II hoods identified by the symbol on the specifications label The power supply cable must be long enough to permit connecting the appliance to the mains socket outlet Do not pull the power supply cable in order to unplug the appliance The electrical components...

Страница 4: ...lace the filters Never flame cook food flambé under the appliance Using free flames might cause fire Do not leave frying pans unattended when frying as the frying oil may catch fire Failure to observe the instructions for cleaning the hood and replacing the filters may result in a fire The fume extractor hood must never be opened without the grease filters installed and it should be kept under con...

Страница 5: ...is not fitted with a plug connect the wires according to the following table WARNING INSTALLATION Declaration of conformity This appliance has been designed manufactured and marketed in compliance with safety objectives of the LowVoltage Directive 2014 35 EU the ecodesign requirements of european regulations n 66 2014 n 327 2011 n 244 2009 n 245 2009 n 1194 2012 n 2015 1428 the protection requirem...

Страница 6: ...KIT is furnished or must be bought separately Note If furnished in certain cases the additional activated carbon filtering system may be installed on the hood Information about the conversion of the hood from suction version to filtering version is present in this manual Ducting version In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connec...

Страница 7: ... The service number is also indicated on the guarantee booklet Your full address Your telephone number If any repairs are required please contact an authorised After sales Service to guarantee that original spare parts will be used and repairs carried out correctly TROUBLESHOOTING GUIDE AFTER SALES SERVICE Never use steam cleaning equipment Disconnect the appliance from the power supply IMPORTANT ...

Страница 8: ...er It absorbs unpleasant odours caused by cooking The saturation of the charcoal filter occurs after more or less prolonged use depending on the type of cooking and the regularity of cleaning of the grease filter In any case it is necessary to replace the cartridge at least every six mounths or when the filter saturation indication system if envisaged on the model in possession indicates this nece...

Страница 9: ...2 Please check the plate in order to verify the total absorption and the light absorption Components not provided with the product Lamp Power W Socket Voltage V Dimension mm ILCOS D Code according IEC 61231 28 E14 230 67 Light Center Length HSGSB C UB 28 230 E14 67 Replacing lamps Remove the filters and remove the burnt out bulb Refit the filters ...

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...GB15 ...

Страница 18: ...400011101916 GB Printed in Italy 03 2017 ...

Отзывы: