background image

033-03 - Electric kettles

5

- Read the warnings contained in this manual carefully as

they provide important information concerning safety
during the installation, use and maintenance of the ap-
pliance.

- Keep these instructions carefully!
- Only personnel trained for its specific use should use the

equipment.

-

Keep the appliance under control during use.

-

The appliance should be used only for the purpose for

which it has been specifically designed; other uses are im-
proper and hence dangerous.
-

During operation surfaces can become hot and require

special operation.
-

Unplug the appliance in case of failures or improper

GENERAL REMINDERS

operation.
-

Apply exclusively to a service centre for repairs or

maintenance.
-

Any important information about the appliance requi-

red for technical service is contained in the technical data
plate (see figure “View of appliance”). 
-

If technical assistance is required, the trouble must be

described in as much detail as possible, so that a service
technician will be able to understand the nature of the pro-
blem.
-

Gloves should be worn to protect the hands during in-

stallation and maintenance operations.

Warning! :  Follow the fire prevention regulations very
carefully.

2 - CHARACTERISTICS OF THE APPLIANCES

These appliances are used for professional purposes. Installation, re-
pair and use must be carried out by expert personnel.

The data plate is located on the front part of the appliance (on the
control panel).

3 - TECHNICAL DATA

Description

("A" as end letter = pressure kettle)

Width (A)

Depth (B)

Height (C)

Vat diameter

Vat height

Total volume

Usable volume

Voltage/Input

Power

Power cable

Hot water connection

Cold water connection

Water pressure

Jacket volume

Jacket pressure

 

mm

mm

mm

mm

mm

lt

lt

kW

 

mm

mm

kPa

lt

bar

800

900

875

600

415

110

100

3N 400V / 50hz

16

5 x 2.5 mm

2  

10

10

50 - 300

0.5

800

900

875

600

540

145

135

3N 400V / 50hz

18

5 x 6 mm

2  

10

10

50 - 300

0.5

1000

1200

875

750

520

215

200

3N 400V / 50hz

32

5 x 10 mm

2  

10

10

50 - 300

0.5

1150

1300

875

900

570

330

300

3N 400V / 50hz

36

5 x 10 mm

2  

10

10

50 - 300

0.5

800

900

530

600

415

110

100

3N 400V / 50hz

16

5 x 2.5 mm

2  

10

10

50 - 300

0.5

800

900

530

600

540

140

135

3N 400V / 50hz

18

5 x 6 mm

2  

10

10

50 - 300

0.5

1250

1400

875

900

790

535

500

3N 400V / 50hz

36

5 x 10 mm

2  

10

10

50 - 300

0.5

AGB 384/WP

AGB 386/WP

AGB 390/WP

AGB 392/WP

AGB 396/WP AGB 399/WP

AGB 401/WP

AGB 372/WP AGB 375/WP

AGB 377/WP

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

Содержание AGB 372/WP

Страница 1: ...r installation use and maintenance 06 2009 ELECTRIC KETTLES 0033_GB_42 Validity from serial number 92204355 AGB 372 WP AGB 375 WP AGB 377 WP AGB 384 WP AGB 386 WP AGB 390 WP AGB 392 WP AGB 396 WP AGB 399 WP AGB 401 WP ...

Страница 2: ...ial bonding 7 Connection to waterworks 7 Commissioning and testing pag 7 Maintenance of the appliance 7 Possible failures and their elimination 7 Use and cleaning 8 Warnings and hints for user 8 Instructions for use 8 Filling the jacket 8 Details regarding the operation of the pressure kettles 8 Switch on start of cooking and switch off 8 Cleaning and care of the appliance 8 Daily cleaning 9 Speci...

Страница 3: ...C S 2 1 0 T C E F 1 2 3 4 5 6 Technical data plate Hot water connection to 10 mm Electrical connection Cold water connection to 10 mm Selector Operation light Pressure gauge Cooking vat drainage tap Vat water feed tap Jacket level tap Dimensions ...

Страница 4: ...033 03 Electric kettles 4 Controls 0 4 0 6 0 80 1 0 0 0 4 0 6 0 8 0 10 0 0 2 3 1 0 2 3 1 0 2 3 1 0 2 3 1 Manual vapour vent Valve autoclave 0 Off 1 50 power 2 75 power 3 100 power ...

Страница 5: ...r pressure kettle Width A Depth B Height C Vat diameter Vat height Total volume Usable volume Voltage Input Power Power cable Hot water connection Cold water connection Water pressure Jacket volume Jacket pressure mm mm mm mm mm lt lt kW mm mm kPa lt bar 800 900 875 600 415 110 100 3N 400V 50hz 16 5 x 2 5 mm2 10 10 50 300 0 5 800 900 875 600 540 145 135 3N 400V 50hz 18 5 x 6 mm2 10 10 50 300 0 5 1...

Страница 6: ...adjusta ble feet A significantly uneven or sloping stance can affect the operation of the appliance adversely Installation Warning Only qualified technicians must perform the installation maintenance and test of the appliance Warning Before connecting any parts of the ap pliance to supplies make sure that the latter is equiva lent the requirements stated in the technical data plate if the applianc...

Страница 7: ... all safety requirements in current standards statu tory regulations and directives have been met that the water connections are leak free that the electrical connection has been performed accor ding to standards In addition check that once the appliance has been instal led the power cord is neither subject to stretch nor in con tact with nor surfaces Now proceed to light the appliance as directed...

Страница 8: ...that the valve is in a resting position Start cooking at full power When steam starts to come out of the valve reduce heating power The steam coming out of the valve must be constant and light The pressure inside the cooking vat can reach a maximum of 0 05 bar On request the appliance can be equipped with a pressure gauge that shows the pressure inside the cooking vat Turn off the appliance after ...

Страница 9: ...nd the vat and or the jacket is are empty The manufacturer shall not be held responsible nor has any warranty commitments for damage caused by non compliance with prescriptions or by installa tion not in conformity with instructions The same applies in case of improper use or diffe rent application by the operator THE 2002 96 EC DIRECTIVE WEEE information to users This informational note is meant ...

Страница 10: ... PE 1 2 3 4 5 6 1 2 3 4 5 6 0 P1 P2 P3 P4 SE 2 3 1 SE P1 P2 P3 P4 1 2 3 4 RM 1 3 5 2 4 6 1 3 5 2 4 6 12 11 2 1 AGB 372 WP AGB 375 WP AGB 377 WP AGB 396 WP AGB 399 WP AGB 401 WP mA Line input terminal board TS Safety thermostat C1 Electromagnetic switch L1 Pilot lamp green voltage L2 Pilot lamp yellow TL Thermostat R1 Heating element R2 Heating element SE Four position selector switch Rm Relay ...

Страница 11: ...ATO T S T L PV M 1 4SL Only for mod 200 300 Wiring diagrams L1 Green operation light L2 Orange operation light LA Red alarm operation light LR Orange reservoir light TL Working thermostat TS Safety thermostat C1 Electromagnetic switch max C2 Electromagnetic switch min SL Level card SE Three position selector switch R1 Heating element mA Line terminal board AGB 384 WP AGB 386 WP AGB 390 WP AGB 392 ...

Страница 12: ...O COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Отзывы: