S E R V I C E
Whirlpool Europe
ADP 923/2 WH
06.10.1999 / Page 3
Customer Service
8511 923 10301
Doc. No: 4812 718 14714
Technical data
Valve
Inlet valve
Voltage
220-240
V
Power consumption
6
W
Resistance
3750
Ω
Regeneration valve
Voltage
220-240
V
Power consumption
6
W
Resistance
3750
Ω
Thermostates
Double thermostat in the Door
NA58
Color code
grey
Temperature
58
˚C
closes when temperature is reached
NC72
Color code
red
Temperature
72
˚C
opens when temperature is reached
Water measuring
Remove the coases sieve, put into the sump a
meassuring meter, look the height of the water
level
Working level
110
mm
Safety level
125
mm
Pressostat
Working level
Niveau
80/60
±
3 mm
Safety level (against overflow)
Niveau
125/75
±
3mm
Regeneration and Volume
Setting “Without salt“
Volume
215
ccm
Salt consumption
-
gr
Waterhardness
0 - 9
˚dH
Setting “-“
Volume
215
ccm
Salt consumption
40
gr
Waterhardness
10 - 23
˚dH
Setting “+“
Volume
215
ccm
Salt consumption
60
gr
Waterhardness
24 - 54
˚dH