background image

S E R V I C E

12.07.1999 / Page 2

ADP 905/3 WH

Whirlpool Europe

Doc. No: 4812 718 14342

8542 905 01410

Customer Service

Technical data

Dimension

Height

85.0

cm

Width

59.5

cm

Depth

59.2

cm

Weight

58.3

kg

Electronic boards

Service boards

see spare part list

Serial boards
UB

4619 720 80271

CB

096911

Dataset

096901

Succession of programs

Programs

see program diagram

Succession

1a-3b-4b-5a-6a

Program information

Start indicator

Volume (normal program)

Water

Volume

Level

Regeneration

0.3 l

15 mm

Back rinse 3x

1.0 l

68 mm

Prewash

4.8 l

122 mm

Main wash

4.5 l

121 mm

Intermediate rinse 1

4.0 l

120 mm

Intermediate rinse 2

4.0 l

120 mm

Clear rinse

4.0 l

120 mm

Safety / overflow

8.5 l

141 mm

Measuring the level

Remove the coarse sieve, put in a measuring
meter into the sump, measure the hight of the
water level.

Detergent max.

Pre-wash

10

cm

3

Main-wash

45

cm

3

Rinse aid

125

cm

3

6 Dosage steps

1 - 6

ml

Water softener

Saltcontainer

2

kg

Resin container

900

cm

3

Regeneration dosage

300

cm

3

Water pressure

Inlet pressure

0.3-10

bar

Spray pump pressure

0.4

bar

Rotations

Spray pump motor

2800

RPM

Drain pump motor

3000

RPM

Spray arm lower

20 - 40

RPM

Spray arm upper

25 - 35

RPM

Ceiling rotor

45 - 65

RPM

Flow rates / Inlet volume

Flow meter (at 0.3 bar
= quantity 1.1 l/min)

208

lmp/l

Spray pump

~ 70

l/min

Drain pump

16

l/min

Pump height max.

1.1

m

Inlet valve

4.5

l/min

Spray arm lower

33

l/min

Sprayarm upper

27

l/min

Ceiling rotor

10

l/min

Electrical data

Base data

Voltage

220/230

V

Frequency

50

Hz

Total power

2.0-2.2

kW

Fuse

10

A

Motor

Spray pump motor

Voltage

220/230

V

Power consumption

160

W

HI

81

HA

44

Capacitor

4

µ

 F

Содержание ADP 905/3 WH

Страница 1: ...ist 4 5 Exploded view 6 7 Circuit diagram 8 Program diagram 9 Text Legend 10 16 Family Global A5 Service Manual Dishwasher ADP 905 3 WH ADP 905 3 WH This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 12 07 1999 Subject to modification Document No 4812 718 14342 ...

Страница 2: ... Remove the coarse sieve put in a measuring meter into the sump measure the hight of the water level Detergent max Pre wash 10 cm3 Main wash 45 cm3 Rinse aid 125 cm3 6 Dosage steps 1 6 ml Water softener Saltcontainer 2 kg Resin container 900 cm3 Regeneration dosage 300 cm3 Water pressure Inlet pressure 0 3 10 bar Spray pump pressure 0 4 bar Rotations Spray pump motor 2800 RPM Drain pump motor 3000...

Страница 3: ...tat self reset 85 C Water valves Single valve at inlet hose Voltage 220 240 V Frequency 50 60 Hz Resistance 3 76 kΩ Regenerating valve Voltage 220 240 V Frequency 50 60 Hz Resistance 3 13 kΩ Coil of dispenser Voltage 220 240 V Frequency 50 60 Hz Resistance 1 5 kΩ Reedcontact flow meter NTC 15 C 75 kΩ 20 C 62 kΩ 30 C 43 kΩ 40 C 28 kΩ 50 C 19 kΩ 60 C 13 kΩ 70 C 9 kΩ 80 C 6 kΩ 85 C 5 kΩ Regeneration ...

Страница 4: ...spraypump cpl 405 0 4812 360 18371 Spray pump 405 1 4819 515 28158 Gasket 420 0 4812 121 18132 Capacitor 421 0 4812 121 18161 Interf filter 430 0 4812 360 18357 Pump draining 430 1 4812 466 68506 Shaft seal 450 0 4812 259 28684 Heating element Pos No 12NC Code Description 480 0 4812 321 28386 Cable harness set 480 1 4812 321 28371 Cable 480 3 4812 401 18418 Protector f wiring 490 0 4819 321 18136 ...

Страница 5: ...t 791 5 4812 466 68504 Gasket 794 1 4819 530 58032 Gasket 20x2 5 901 0 4822 401 10492 Clamp hose 14 24 mm 901 1 4812 401 18424 Strap 050 0 901 2 4812 401 18157 Strap 32 50 9 C61 901 5 4812 401 48573 Strap 028 6 901 6 4812 401 48574 Strap 038 1 901 7 4812 401 18427 Strap 031 6 904 0 4812 462 78998 Threaded cap 904 2 4812 462 79635 Cover WH 3 5x5 904 4 4812 462 79659 Threaded cap 910 0 4812 502 1838...

Страница 6: ...S E R V I C E 12 07 1999 Page 6 ADP 905 3 WH Whirlpool Europe Doc No 4812 718 14342 8542 905 01410 Customer Service Exploded view ...

Страница 7: ...S E R V I C E Whirlpool Europe ADP 905 3 WH 12 07 1999 Page 7 Customer Service 8542 905 01410 Doc No 4812 718 14342 Exploded view ...

Страница 8: ... LS6 Water leakage switch L Line MS Main switch NTC Thermostat temp sensor N Neutral PRG Plug to program RV Water hardness switch RE2 Heating relay RR SA Reed relay salt RR RA Reed relay rinsaid SAB Sprayarm blocked SPM Sprayarm motor THS Safety thermostat THS 2 Fuse TBL Power supply terminal TL Winding protective contact UB User board VM Fan ventilator WV1 Water inlet valve WV2 Water regenerating...

Страница 9: ...S E R V I C E Whirlpool Europe ADP 905 3 WH 12 07 1999 Page 9 Customer Service 8542 905 01410 Doc No 4812 718 14342 Program diagram ...

Страница 10: ...S E R V I C E 12 07 1999 Page 10 ADP 905 3 WH Whirlpool Europe Doc No 4812 718 14342 8542 905 01410 Customer Service Text Legend ...

Страница 11: ...S E R V I C E Whirlpool Europe ADP 905 3 WH 12 07 1999 Page 11 Customer Service 8542 905 01410 Doc No 4812 718 14342 Text Legend ...

Страница 12: ...S E R V I C E 12 07 1999 Page 12 ADP 905 3 WH Whirlpool Europe Doc No 4812 718 14342 8542 905 01410 Customer Service Text Legend ...

Страница 13: ...S E R V I C E Whirlpool Europe ADP 905 3 WH 12 07 1999 Page 13 Customer Service 8542 905 01410 Doc No 4812 718 14342 Text Legend ...

Страница 14: ...S E R V I C E 12 07 1999 Page 14 ADP 905 3 WH Whirlpool Europe Doc No 4812 718 14342 8542 905 01410 Customer Service Text Legend ...

Страница 15: ...S E R V I C E Whirlpool Europe ADP 905 3 WH 12 07 1999 Page 15 Customer Service 8542 905 01410 Doc No 4812 718 14342 Text Legend ...

Страница 16: ...S E R V I C E 12 07 1999 Page 16 ADP 905 3 WH Whirlpool Europe Doc No 4812 718 14342 8542 905 01410 Customer Service Text Legend ...

Отзывы: