S E R V I C E
Whirlpool Europe
ADP 2656 WHM
20.10.2000 / Page 3
Customer Service
8542 656 10510
Doc. No: 4812 718 15739
Technical data
Flow rates / Inlet volume
Flow meter (at 0.3 bar
= quantity 1.1 l/min)
208
lmp/l
Spray pump
~ 70
l/min
Drain pump
16
l/min
Pump height max.
1.1
m
Inlet valve
4.5
l/min
Valve for Zone washing
30
l/min
Spray arm lower
~ 33
l/min
Sprayarm upper
~ 27
l/min
Ceiling rotor
~ 10
l/min
Electrical data
Base data
Voltage
220/230
V
Frequency
50
Hz
Total power
2.0-2.2
kW
Fuse
10
A
Motor
Spray pump motor
Voltage
220/230
V
Power consumption
160
W
HI
81
Ω
HA
44
Ω
Capacitor
4
µ
F
Drain pump motor
Voltage
220/240
V
Power consumption
30
W
Resistance
146
Ω
Heating
1 Element system
Voltage
220/230
V
Power consumption
1.87/2.04 kW
Resistance
24.5
Ω
Heating speed
~ 2.0
˚C/min
Temperature on surface
~ 115
˚C
Safety thermostat
self reset
85
˚C
Potentiometer
Points of meassurement: 1(black) to 2 (middle)
Position 0
0.0
k
Ω
Position 1
0.5
k
Ω
Position 2
1.0
k
Ω
Position 3
1.4
k
Ω
Position 4
1.8
k
Ω
Position 5
2.3
k
Ω
Position 6
2.6
k
Ω
Water valves
Single valve at inlet hose
Voltage
220/240
V
Frequency
50/60
Hz
Resistance
3.76
k
Ω
Regenerating valve
Voltage
220/240
V
Frequency
50/60
Hz
Resistance
3.13
k
Ω
Valve for zone washing
Voltage
220-240
V
Frequency
50/60
Hz
Resistance
4
k
Ω
Coil of dispenser
Voltage
220/240
V
Frequency
50/60
Hz
Resistance
1.5
k
Ω
Reedcontact
flow meter
salt control
rinse aid control
NTC
20 ˚C
58.1
k
Ω
25 ˚C
47.1
k
Ω
30 ˚C
38.2
k
Ω
40 ˚C
25.4
k
Ω
50 ˚C
17.2
k
Ω
60 ˚C
11.8
k
Ω
70 ˚C
8.3
k
Ω
80 ˚C
6
k
Ω
85 ˚C
4
k
Ω