S E R V I C E
Whirlpool Europe
ADG 758
16.11.2005 / Page 3
Customer Service
8511 155 10811
Doc. No: 4812 728 11715
Technical data
Water safty options
Waterstop system
Aquasafe
Water inlet valve/ Aquastop
Voltage
220-240
V
±
10%
Frequency
50/ 60
Hz
Inlet pressure
0.5 - 10
bar
Flow rate
3.5
l/min
±
7%
Resistance
~ 4.12
k
Ω
Regeneration valve
Voltage
220-240
V
Frequency
60
Hz
Resistance
~ 3.75
k
Ω
Coil of dispenser
Voltage
220/ 240 V
±
10%
Frequency
50/ 60
Hz
Resistance
~ 1.33
k
Ω
Level pressure switch and
Door micro switch
Max carrying capacity
of the contacts
250 V
14 (4) A
NTC
23 ˚C
~ 14
k
Ω
25 ˚C
~ 11,5
k
Ω
30 ˚C
~ 9,5
k
Ω
Indication lights
Voltage
230
V
Power consumption
0.5
W
Micro switch safty device
Voltage
250
V
Power consumption
3 (4)
W
Push buttons
Voltage
250
V
Power consumption
16 (4)
W
Suppressor
Capacitor
1 x 0.1
µ
F (X1) + 2 x 2700 pF
(Y)
Resistance
2.2
M
Ω
Safty system against water-leakage
Aq floater switch
(Floater switches of the inlet valve and on the drain
pump)
Regeneration and Volumes
Salt container volume
1.5
kg
Volume for regeneration
320
cm
3
Default Water hardness
setting
3
Adjustment
on display
German
degrees ˚dH
French
degrees ˚fH
Regenaration
H0
< 9
< 15
Disabeld
H1
< 15
< 25
Every 5 cycles
H2
< 23
< 40
Every 4 cycles
H3
< 34
< 60
Every 3 cycles
H4
< 46
< 80
Every 2 cycles
H5
< 58
< 100
Every cycle