4
TO FIX THE COOKER TO THE REAR WALL
WARNING -
For safety reasons and to prevent tipping of the appliance,
these stabilizing means must be installed.
The cooker is equipped with 2 chains fixed on each side at the rear of
the cooker near the top (see Fig. A). The chains are fitted with spring
clips which must be clipped to the screw eyes provided with the cooker.
Install the screw eyes as follows :
1.
Drill four 6mm holes (position 1 - 2 - 3 - 4) in the wall
as in Fig. A.
2.
Insert part
R
into the holes then screw in the screw eyes part
G
see Fig. B.
Note: If the part provided is not suitable for the wall material please
use an appropriate device to ensure secure holding of the screw
eyes to the wall.
3.
Bring the cooker near the wall and clip the chains on the
screw eyes as in Fig. C.
IMPORTANT: If the cooker is moved for any reason
(e.g. maintenance) resulting in the cooker being unclipped from the
wall, the cooker must be re-clipped to the wall at the completion of
the task.
GAS CONNECTION
Check gas pressure, note the correct setting from the data plate
sealed inside the front appliance drawer .
*
IT IS RECOMMENDED THAT A SERVICE TAP AND UNION BE
FITTED ADJACENT TO THE APPLIANCE INLET TO FACILITATE
FUTURE SERVICING.
5 burner models: set the burner pressure to 1kPa for Natural Gas
and 2.75kPa for U-LPG with the wok burner operating a full rate.
For commissioning of the appliance with the Bromic regulator for
Natural Gas , the test point pressure should be 1.00kPa with all
burners operating on HIGH.
Apply a manometer to the test nipple and reset the regulator if
necessary. Do not forget to replace the test nipple screw and to
leave the instruction book with the user.
This appliance from the factory suitable for NATURAL gas but, if
necessary, can be adjusted for U-LPG by authorised person.
accordance with the manufacturers installation instructions,
relevant local fitting regulations, municipal building regulations,
the AS5601 code for gas burning appliances and equipment and
The appliance shall be installed by an authorized person in
For the adjustments to U-LPG please operate as specified in the
paragraph GAS CONVERSION AND ADJUSTMENT (pag 4).
The Gas Connection is male 1/2" BSP and is situated at the right or left,
hand rear of the appliance, approximately 40mm from the side
Gas Installation must be made in accordance with AS5601;
also refer to rangehood manufacturers recommendations.
Installing the Gas Cooker:
(Flexible connections are NOT permitted with this
appliance)
· An inlet manifold extension pipe must be fitted to the
appliance. Part supplied in the drawer of the appliance.
· Ensure that the pipe is connected using the washer provided
and that the bracket is screwed to the appliance as shown in
the diagram below.
· Fit the supplied pressure regulator. Ensure the arrow is pointing
towards the appliance and that the pressure test point is
accessible from under the appliance when the product is pushed
back into the final position.
Push the cooker back and install the stabilizing chains.
Connect the appliance inlet manifold to the fixed consumer
piping outlet using only fixed piping. This final connection is
made when the product is pushed back into position by access
under the cooker.
Fig. B
Fig. C
G
wall
wall
Fig. A
76 mm
550 mm
G
R
Hole
55 mm
chain
Position
1
Position
2
55 mm
Position
3
Position
4
Inlet Manifold Extension.
Supplied with product.
To be fitted by installer
Regulator
Fixed Pipe to
Connection Point
Washer
Screw