background image

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed

Parts supplied

Gas pressure regulator

Burner grates

Burner heads and caps

Clamp brackets (2)

2

¹⁄₂

" (6.4 cm) clamping screws (2)

Foam tape seal

Parts needed

Check local codes and consult gas supplier. Check existing gas 
supply and electrical supply. See “Electrical Requirements” and 
“Gas Supply Requirements” sections.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do 
not obstruct flow of combustion and ventilation air. 

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the underside of the 
cooktop burner box.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

The cooktop should be installed in a location away from 
strong draft areas, such as windows, doors and strong 
heating vents or fans.

All openings in the wall or floor where cooktop is to be 
installed must be sealed.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

Grounded electrical supply is required. See “Electrical 
Requirements” section. 

Proper gas supply connection must be available. See “Gas 
Supply Requirements” section.

The gas and electric supply should be located as shown in 
“Gas and Electric Connection Locations” in the “Location 
Requirements” section so that they are accessible without 
requiring removal of the cooktop.

IMPORTANT: To avoid damage to your cabinets, check with your 
builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the 
Manufactured Home Construction and Safety Standard, Title 24 
CFR, Part 3280 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD Part 280). When such 
standard is not applicable, use the Standard for Manufactured 
Home Installations, ANSI A225.1/NFPA 501A or with local codes.

In Canada, the installation of this cooktop must conform with the 
current standards CAN/CSA-A240-latest edition, or with local 
codes.

Product Dimensions

30" (76.2 cm) Model

36" (91.4 cm) Model

Gas and Electric Connection Locations

Tape measure

Flat-blade screwdriver

¹⁵⁄₁₆

" combination wrench

Pipe wrench

Channel lock pliers

Marker or pencil

Pipe-joint compound 
resistant to LP gas

Noncorrosive leak-detection 
solution

A. 30" (76.2 cm)
B. 20

¹⁄₈

" (51.1 cm) 

C. 2

²⁷⁄₃₂

" (7.2 cm)

A. 36" (91.4 cm)
B. 20

¹⁄₈

" (51.1 cm) 

C. 2

²⁷⁄₃₂

" (7.2 cm)

A. Gas pressure regulator (supplied) - arrow pointed 

toward cooktop

B. 3 prong grounding type outlet with correct polarity
C. 18" (45.7 cm) minimum
D. Gas shutoff valve

A

C

B

A

B

C

CL

C

A

B

D

Содержание 9761893A

Страница 1: ...AS DE CÂBLAGE 19 9761893B You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many ...

Страница 2: ...ier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions IMPORTANT Do not install a ventilation system that blows air downward toward this gas cooking appliance This type of ventilation system may caus...

Страница 3: ...ed electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The gas and electric supply should be located as shown in Gas and Electric Connection Locations in the Location Requirements section so that they are accessible without requiring removal of the cooktop IMPORTANT To avoid damage to your cabinets che...

Страница 4: ...tection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this range be provided Electronic ignition systems operate within wide voltage limits...

Страница 5: ...flexible stainless steel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the cooktop Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings...

Страница 6: ... wiring during installation The pressure regulator and flexible stainless steel gas supply line connector can be assembled to the cooktop now or after the cooktop is installed in the cutout See Make Gas Connection section 1 Using two or more people place the cooktop upside down on a covered surface 2 Remove foam strip from hardware package Remove backing from foam strip Apply foam strip adhesive s...

Страница 7: ...inked Complete Connection 1 Open the manual shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe 2 Test all connections by brushing on an approved noncorrosive leak detection solution If bubbles appear a leak is indicated Correct any leak found 3 Remove surface burner heads caps and grates from parts package Insert tab in burner head into notch in burn...

Страница 8: ...occur Occasional orange flashes are normal and reflect different elements in the air or gas 3 Repeat at LO position 4 After verifying the proper burner operation turn the control knobs to OFF If burners do not light properly Turn surface burner control knob to the OFF position Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown Check that the ga...

Страница 9: ... G L1 A B RF 1 Switch Valve B 18 BK 7 A LF 2 B 18 BK 6 A 18 W 11 18 BU 18 18 BU 17 18 W 12 18 W 10 18 BU 15 18 BU 14 18 BK 4 LR 4 B 18 BK 5 A 5 18 BK 4 20 OR 19 RR Switch Valve Switch Valve Switch Valve Igniter Igniter Spark Module Wiring Diagram 36 91 4 cm Cooktop 20 OR 22 2 20 OR 21 4 18 W 2 20 OR 19 1 N 3 5 5 L1 N 4 L1 N 3 L1 N 2 L1 N 20 OR 20 18 W 9 18 BK 1 18 G 3 Power Supply N L1 G L1 1 L1 N...

Страница 10: ...10 Notes ...

Страница 11: ...n décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du télé...

Страница 12: ...fications électriques Une source de gaz adéquate doit être disponible Voir la section Spécifications de l alimentation en gaz Veiller à placer les sources de gaz et d électricité selon les indications de la section Emplacements des raccordements des sources de gaz et d électricité dans la section Exigences d emplacement de façon à être accessibles sans dépose de la table de cuisson IMPORTANT Pour ...

Страница 13: ... 2 7 2 cm A Détendeur fourni flèche pointée vers la table de cuisson B Prise de courant à 3 broches reliée à la terre avec polarité correcte C 18 45 7 cm minimum D Robinet d arrêt A B C C L C A B D A 18 45 7 cm de dégagement minimum entre placard mural et plan de travail B Placard C 30 76 2 cm sur les modèles de 30 76 2 cm 36 91 4 cm sur les modèles de 36 91 4 cm D Profondeur maximum recommandée d...

Страница 14: ... récente édition du code national en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent être effectués selon les instructions du fabricant Type de gaz Gaz naturel La conception de cette table de cuisson a été homologuée par Underwriters Laboratories UL cUL pour l alimentation au gaz naturel ou pour l alimentation au propane après ...

Страница 15: ...e La canalisation doit se trouver en un endroit facilement accessible pour les manœuvres d ouverture fermeture Ne pas entraver l accès au robinet d arrêt manuel Le robinet d arrêt manuel est prévu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson Détendeur Le détendeur fourni avec cette table de cuisson doit être utilisé La pression d alimentation du détendeur doit être comme suit...

Страница 16: ...n 1 6 mm à partir du bord des côtés du châssis en acier inoxydable et à l arrière REMARQUE La bande de mousse protège la face inférieure du châssis de la table de cuisson des débris et l aide à reposer à plat sur des plans de travail irréguliers Installationdelatabledecuisson 1 Ôter les 2 vis situées de chaque côté de la boîte des brûleurs de la table de cuisson 2 Fixer les 2 brides de retenue à l...

Страница 17: ...extrémité filetée la plus grosse des adaptateurs de raccord flexible voir B et F ci dessous 2 Fixer un raccord d adaptation sur le régulateur de pression du gaz et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux raccords d adaptation 3 Utiliser une clé mixte de et une pince multiprise pour fixer le raccord flexible sur les raccords d adaptation Veiller...

Страница 18: ... surface en moins de 4 secondes Lors de l allumage initial du brûleur de surface le délai d allumage peut être supérieur à 4 secondes du fait de la présence d air dans la canalisation de gaz 2 Vérifier que la flamme est bleue à la position HI Elle doit être propre et douce On ne doit pas observer de pointe jaune ni d effet de soufflage ou de séparation entre les flammes et le brûleur Il est normal...

Страница 19: ...17 18 BL n 12 18 BL n 10 18 BU n 15 18 BU n 14 18 N n 4 Arrière gauche n 4 B 18 N n 5 A n 5 18 N n 4 20 OR n 19 Arrière droit Source D Alimentation Allumeur Allumeur Allumeur Allumeur Contacteur du robinet Contacteur du robinet Contacteur du robinet Contacteur du robinet Schéma de câblage Table de cuisson 36 91 4 cm 20 OR n 22 Allumeur n 2 20 OR n 21 n 4 18 BL n 2 20 OR n 19 n 1 N n 3 n 5 n 5 L1 N...

Страница 20: ...9761893B 2012 Whirlpool Corporation All rights reserved Tous droits réservés 8 12 Printed in U S A Imprimé aux É U ...

Отзывы: