15

Connect Vent

1.

Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured to
exhaust hood with a 4" (10.2 cm) clamp.

2.

Move dryer into final position. Do not crush or kink vent. Make
sure dryer is level.

Complete Installation

1.

With dryer in final position place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.

2.

Plug in dryer or reconnect power.

3.

Check dryer operation (some accumulated time may be on
the timer due to factory testing). 

Insert coins in slide and press slide in slowly. (Operating time
will accumulate per number of coins and type of timing cam
used.) Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up.

NOTE:

Dryer door must be closed for dryer to operate. When

door is open, dryer stops, but timer continues to run. To
restart dryer, close door and push START/RESTART button.

4.

If drying time is too long, make sure lint screen is clean.

5.

Now start the dryer and allow it to complete a full heat cycle
(not air cycle) to make sure it is working properly.

A.

³⁄₄

" conduit connector

B. Neutral (white or center)
C. 10-gauge, 3 wire with ground wire in

flexible metallic conduit

A. External ground conductor screw
B. Center terminal block screw
C. Outer terminal block screws
D. Neutral (center wire)
E. Appliance neutral ground wire

Shape ends
of wires into
a hook.

Strip 3

¹⁄₂

" (8.9 cm) of outer

covering from end of cable. Strip
insulation back 1" (2.5 cm). If using
3 wire cable with ground wire, cut
green or bare wire even with outer
covering.

Three wire with ground wire: green or bare
wire cut short. Wire is not used. Dryer is
grounded through neutral conductor.

to 
disconnect
box

1" (2.5 cm)
of wires
stripped of
insulation

3-1/2" (8.9 cm)

5.

Loosen or remove the center terminal
block screw.

6.

Place the hooked end of the neutral wire
(white or center) of the direct wire cable
under the center screw of the terminal
block (hook facing right). Squeeze
hooked end together. Tighten screw.

7.

Place the hooked ends of the other
direct wire cable wires under the outer
terminal block screws (hook facing right).
Squeeze hooked ends together. Tighten
screws.

8.

Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.

5.

Remove the center terminal block screw.

6.

Remove the appliance neutral ground wire
from the external ground conductor screw.
Connect the appliance neutral ground wire
and the neutral wire (white or center) of the
direct wire cable under the center, silver-
colored terminal block screw. Tighten
screw.

7.

Connect the other wires to outer terminal
block screws. Tighten screws.

8.

Insert tab of the terminal block cover into
slot of the dryer rear panel. Secure cover
with hold-down screw.

9.

After reattaching the terminal cover,
connect a separate copper ground wire
from the external ground connector screw
to an adequate ground.

If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.

Direct Wire, 
Three-wire electrical connection:

Use this method where local codes permit
connecting neutral ground wire to 
neutral wire:

Use this method where local codes do
not permit connecting neutral ground
wire to neutral wire:

A

B

C

A

B

C

D

E

A. Separate copper ground wire
B. External ground conductor screw
C. Appliance neutral ground wire
D. Center terminal block screw
E. Outer terminal block screws
F. Neutral (center wire)

F

E

D

A

C

B

Содержание 8TCEM2760KQ0

Страница 1: ...INSTALLATION INSTRUCTIONS COMMERCIAL DRYER Gas or Electric Table of Contents 2 W10103110 ...

Страница 2: ...instructions DANGER WARNING TABLE OF CONTENTS DRYER SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Electrical Requirements 6 Gas Supply Requirements 7 Venting Requirements 8 INSTALLATION INSTRUCTIONS GAS DRYER 10 Install Coin Slide and Coin Box 10 Make Gas Connection 10 Connect Vent 10 Complete Installation 10 INSTALLATION INSTRUCTIONS ELECTRIC DRYER 11 Install Coin...

Страница 3: ...re electric shock or injury to persons when using the dryer follow basic precautions including the following WARNING Read all instructions before using the dryer Do not place items exposed to cooking oils in your dryer Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire Do not dry articles that have been previously cleaned in washed in s...

Страница 4: ...ered for ease of installation servicing and compliance with local codes and ordinances If closet door is installed the minimum unobstructed air opening in the top and bottom is required Louvered doors with equivalent air openings are acceptable The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet as the dryer WARNING Explosion Hazard Keep flammab...

Страница 5: ...nal exhaust elbow is used closet door Front View 3 7 6 cm 3 7 6 cm 24 in2 155 cm2 48 in2 310 cm2 Opening is the minimum for a closet door Louvered doors with equivalent air openings are acceptable 0 0 cm Closet door 14 35 6 cm max 1 2 5 cm 0 0 cm 15 38 1 cm 0 0 cm Product Dimensions 27 68 6 cm dryer 27 68 6 cm 37 94 cm 14 35 6 cm ELECTRIC GAS EXHAUST LEFT OR RIGHT SIDE EXHAUST 4 12 1 cm 13 33 cm 1...

Страница 6: ... a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 A four wire or three wire single phase 120 240 volt 60 Hz AC only electrical supply or four wire or three wire 120 208 volt if specified on the model serial rating plate is required on a separ...

Страница 7: ...tall a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For...

Страница 8: ...ound or any object that may be in the path of the exhaust such as flowers rocks or bushes WARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire Flexible metal appliance connector It is recommended that a new flexible stainless steel gas line design certified by CSA International be used for...

Страница 9: ...ny plastic or metal foil vent with rigid metal or flexible metal vent Plan installation to use the fewest number of elbows and turns Allow as much room as possible when using elbows or making turns Bend vent gradually to avoid kinking Vent outlet is located at the center of the bottom dryer back The vent can be routed up down left right behind the dryer or straight out the back of the dryer Vent S...

Страница 10: ...ove cardboard or hardboard from under dryer WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury Make Gas Connection 1 Remove red cap from gas pipe 2 Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing is used be certain there are no kinks ...

Страница 11: ...nstallation For dryers using coin slides use the adapter kit supplied with the dryer WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury 7 Replace the meter case service door Put the coin vault with lock and key in the meter case opening 8 Remove cardboard or hardboard from under dryer Make Electrical Connection Power...

Страница 12: ...tral wire white or center of the power supply cord under the center screw of the terminal block Tighten screw 9 Connect the other wires to outer terminal block screws Tighten screws 10 Tighten strain relief screws 11 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw Four wire power supply cord must have four No 10 copper wires and match a fo...

Страница 13: ...r terminal block screws Tighten screws 8 Tighten strain relief screws 9 Insert tab of the terminal block cover into slot of the dryer rear panel Secure cover with hold down screw D A C B 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire from the external ground conductor screw Connect the appliance neutral ground wire and the neutral wire white or center of the po...

Страница 14: ...l block cover D Hold down screw A to disconnect box B D 5 12 7 cm 1 2 5 cm of wires stripped of insulation C Strip 5 12 7 cm of outer covering from end of cable Leave green or bare ground wire at 5 12 7 cm Cut 1 3 8 cm from 3 remaining wires Strip insulation back 1 2 5 cm Shape ends of wires into a hook C B A E D F 5 Remove the center terminal block screw 6 Remove the appliance neutral ground wire...

Страница 15: ...re cut green or bare wire even with outer covering Three wire with ground wire green or bare wire cut short Wire is not used Dryer is grounded through neutral conductor to disconnect box 1 2 5 cm of wires stripped of insulation 3 1 2 8 9 cm 5 Loosen or remove the center terminal block screw 6 Place the hooked end of the neutral wire white or center of the direct wire cable under the center screw o...

Страница 16: ... the ratchet tooth 5 Place new cam hub side down over clock shaft Line up flat side of shaft with flat side of cam hole Check that drive lug is in place 6 Turn cam until V shaped notch lines up with ratchet tooth 7 Press cam down in place on motor shaft Make sure that V shaped notch clears the ratchet tooth 8 Close and lock the meter case CHANGING TO A 30 OR 60 MINUTE TIMING CAM B C D A A Ratchet ...

Страница 17: ... fuse is not blown Door is closed Controls are set in a running or ON position START button has been pushed firmly For gas dryers check that gas supply shutoff valves are set in open position If you need assistance The Commercial Laundry Support Center will answer any questions about operating or maintaining your dryer not covered in the Installation Instructions The Commercial Laundry Support Cen...

Страница 18: ...W10103110 Printed in U S A 2006 05 2006 ...

Страница 19: ...2 W10103110 ...

Страница 20: ...2 2 4 4 4 6 7 8 10 10 10 10 10 11 11 11 15 15 16 ...

Страница 21: ...3 ...

Страница 22: ...4 ...

Страница 23: ... 9 cm 25 64 8 cm 18 46 7 cm 5 3 7 6 cm 3 7 6 cm 24 in2 155 cm2 48 in2 310 cm2 0 0 cm 14 35 6 cm 1 2 5 cm 0 0 cm 15 38 1 cm 0 0 cm 27 68 6 cm 37 94 cm 14 35 6 cm 4 12 1 cm 13 33 cm 1 3 2 cm 4 10 8 cm 6 15 2 cm 4 10 2 cm 1 2 5 cm 7 18 1 cm 7 20 cm 35 88 9 cm 26 67 3 cm 29 74 3 cm 14 35 9 cm 7 18 4 cm 10 26 cm ...

Страница 24: ...6 ...

Страница 25: ...7 ...

Страница 26: ...8 A B C ...

Страница 27: ...13 4 m 35 ft 10 7 m 27 ft 8 2 m 36 ft 11 0 m 31 ft 9 4 m 27 ft 8 2 m 25 ft 7 6 m 23 ft 7 0 m 0 1 2 3 4 0 1 2 3 4 58 ft 17 7 m 48 ft 14 6 m 38 ft 11 6 m 29 ft 8 8 m 21 ft 6 4 m 28 ft 8 5 m 23 ft 7 0 m 19 ft 5 8 m 17 ft 5 2 m 15 ft 4 6 m A B A E B G C D F C ...

Страница 28: ...10 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 1 2 3 ...

Страница 29: ...11 1 2 3 4 5 6 7 8 1 4 5 ...

Страница 30: ...3 4 12 2 B C A 5 6 7 8 9 10 11 B D C G F E A C B A F G E D C D B A ...

Страница 31: ...13 G F E B A E F D C E C D B A 5 6 7 8 9 D A C B 5 6 7 8 9 10 ...

Страница 32: ...14 1 2 3 4 C D B A A B D 5 12 7 cm 3 8 9 cm C C B A E D F 5 6 7 8 9 10 B C A ...

Страница 33: ...15 1 2 1 2 3 4 5 3 1 2 8 9 cm 5 6 7 8 5 6 7 8 9 A B C A B C D E F E D A C B ...

Страница 34: ...16 1 2 3 4 5 6 7 8 B C D A ...

Страница 35: ...17 ...

Страница 36: ...W10103110 2006 05 2006 ...

Отзывы: