Electrical Requirements

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in 
conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances. 

The National Electric Code requires a 4-wire supply 
connection for homes built after 1996, dryer circuits involved 
in remodeling after 1996 and all mobile home installations.

A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt 
electrical supply, if specified on the serial/rating plate) on a 
separate 30-amp circuit, fused on both sides of the line. A 
time-delay fuse or circuit breaker is recommended. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit. 

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

This dryer is manufactured ready to install with a 3-wire 
electrical supply connection. The neutral ground wire is 
permanently connected to the neutral conductor (white wire) 
within the dryer. If the dryer is installed with a 4-wire electrical 
supply connection, the neutral ground wire must be removed 
from the external ground conductor screw (green screw), and 
secured under the neutral terminal (center or white wire) of 
the terminal block. When the neutral ground wire is secured 
under the neutral terminal (center or white wire) of the 
terminal block, the dryer cabinet is isolated from the neutral 
conductor. 

Use a 4-wire conductor cord when the dryer is installed in a 
mobile home or an area where local codes do not permit 
grounding through the neutral.

A 4-wire power supply connection must be used when the 
appliance is installed in a location where grounding through 
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations, 
(2) mobile homes, (3) recreational vehicles and (4) areas 
where local codes prohibit grounding through the neutral 
conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated 
120/240 volt minimum. The cord should be type SRD or 
SRDT and be at least 4 ft (1.22 m) long. The wires that 
connect to the dryer must end in ring terminals or spade 
terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade 
terminals and UL listed strain relief. The 4-wire power supply 
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper 
wires and match a 4-wire receptacle of NEMA Type 14-30R. The 
ground wire (ground conductor) may be either green or bare. The 
neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade 
terminals and UL listed strain relief. The 3-wire power supply 
cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper 
wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) 
and be:

Flexible armored cable or nonmetallic sheathed copper cable 
(with ground wire), protected with flexible metallic conduit. All 
current-carrying wires must be insulated.  

10-gauge solid copper wire (do not use aluminum).

At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

SAVE THESE  INSTRUCTIONS

■  

For a grounded, cord-connected dryer: 

This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer uses a cord having an equipment-grounding 
conductor and a grounding plug. The plug must be plugged 
into an appropriate outlet that is properly installed and 
grounded in accordance with all local codes and ordinances.

■  

For a permanently connected dryer:

This dryer must be connected to a grounded metal, 
permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and 
connected to the equipment-grounding terminal or lead on 
the dryer.

WARNING:

 

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug on the power 
supply cord: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.

Содержание 8578567

Страница 1: ... VOLT ELECTRIC DRYER Use CareGuide For questions about features operation performance parts accessories or service call 1 800 253 1301 or visit our website at www whirlpool com Table of Contents 2 8578567 ...

Страница 2: ...Connect Vent 12 Level Dryer 13 Complete Installation 13 DRYER USE 14 Starting Your Dryer 14 Stopping and Restarting 14 Changing Cycles and Temperatures 14 Controls 15 Drying Cycle and Temperature Tips 15 Cycles 15 DRYER CARE 16 Cleaning the Dryer Location 16 Cleaning the Lint Screen 16 Cleaning the Dryer Interior 17 Cleaning the Control Panel 17 Removing Accumulated Lint 17 Vacation and Moving Car...

Страница 3: ... have been previously cleaned in washed in soaked in or spotted with gasoline dry cleaning solvents or other flammable or explosive substances as they give off vapors that could ignite or explode Do not allow children to play on or in the dryer Close supervision of children is necessary when the dryer is used near children Before the dryer is removed from service or discarded remove the door to th...

Страница 4: ... will need A location that allows for proper exhaust installation See Venting Requirements A separate 30 amp circuit If you are using a power supply cord a grounded electrical outlet located within 2 ft 61 cm of either side of the dryer See Electrical Requirements A sturdy floor to support the dryer weight dryer and load of 115 lbs 52 kg The combined weight of a companion appliance should also be ...

Страница 5: ... Kit see Assistance or Service Custom undercounter installation Dryer only Recessed or closet installation Dryer only Recessed or closet installation Stacked with stack kit Accessory Mobile Home Additional Location Requirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly...

Страница 6: ...ough the neutral conductors If using a power supply cord Use a UL listed power supply cord kit marked for use with clothes dryers The kit should contain A UL listed 30 amp power supply cord rated 120 240 volt minimum The cord should be type SRD or SRDT and be at least 4 ft 1 22 m long The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends A UL listed s...

Страница 7: ...etal vent to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install flexible metal vent in enclosed walls ceilings or floors Elbows 45 elbows provide better airflow than 90 elbows Clamps Use clamps to seal all joints Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct Do not use duc...

Страница 8: ...or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock WARNING Fire Hazard Use 10 gauge solid copper wire Use a UL listed strain relief Disconnect power before making electrical connections Connect neutral wire white or center wi...

Страница 9: ...d Strip 5 12 7 cm of outer covering from end of cable leaving bare ground wire at 5 12 7 cm Cut 1 3 8 cm from 3 remaining wires Strip insulation back 1 2 5 cm Shape ends of wires into a hook shape A Terminal block cover B Strain relief C Strain relief nut D Power cord If your home has And you will be connecting to Go to section 4 wire receptacle NEMA Type 14 30R A UL listed 120 240 volt minimum 30...

Страница 10: ...utral wire 1 Loosen or remove center terminal block screw 2 Connect neutral wire white or center wire of power supply cord under center screw of the terminal block Tighten screw 3 Connect the other wires to outer terminal block screws Tighten screws 4 Replace the terminal block cover on the back of the dryer 5 Tighten strain relief nut 3 wire connection Direct Wire Use where local codes permit con...

Страница 11: ...any varieties Select the type best for your installation A close clearance installation is shown below Refer to the manufacturer s instructions Over the Top Installation Kit Part Number 4396028 for close clearance alternate installation is available for purchase For ordering information see Assistance or Service Special provisions for mobile home installations The exhaust vent must be securely fas...

Страница 12: ... not use duct tape screws or other fastening devices that extend into the interior of the vent to secure vent ConnectVent 1 To protect the floor use a large flat piece of cardboard from the dryer carton Place cardboard under the entire bottom of the dryer 2 Slide the dryer on the cardboard until it is close to its final location Leave enough room to connect the exhaust vent 3 Using the coupling su...

Страница 13: ...with a damp cloth to remove any dust 10 Set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into a grounded outlet and or electrical supply is connected Household fuse is intact and tight or circuit breaker has not trip...

Страница 14: ...of load being dried See Drying Cycle and Temperature Tips 6 After a short beep sounds press the START button StoppingandRestarting To stop your dryer at any time Turn the cycle knob to the STOP position or open the door To restart the dryer 1 Close the door 2 Select a new cycle and temperature if desired 3 After the beep sounds press the START button ChangingCyclesandTemperatures To change the cyc...

Страница 15: ...kling After the cool down cycle ends the light flashes and an end of cycle signal sounds to indicate the cycle is complete Drying tips Follow care label directions when they are available Remove the load from the dryer as soon as tumbling stops to reduce wrinkling This is especially important for permanent press knits and synthetic fabrics Avoid drying heavy work clothes with lighter fabrics This ...

Страница 16: ...r and free from items that would obstruct the flow of combustion and ventilation air CleaningtheLintScreen Every load cleaning The lint screen is located in the door opening of the dryer Clean it before each load A screen blocked by lint can increase drying time To clean 1 Open the door and pull the lint screen straight up 2 Open lint screen 3 Roll lint off the screen with your fingers Do not rins...

Страница 17: ...or brightly colored cotton items may discolor the dryer interior These stains are not harmful to your dryer and will not stain future loads of clothes Dry unstable dye items inside out to avoid dye transfer CleaningtheControlPanel To clean the control panel use only a warm damp cloth NOTE Do not use abrasive cleaners or scouring pads on the outer surfaces because they will scratch the finish and c...

Страница 18: ... caught between the drum and front or rear of the dryer Check the front and rear edges of the drum for small objects Clean out pockets before laundering Are the four legs installed and is the dryer level front to back and side to side The dryer may vibrate if not properly installed See Installation Instructions Is the clothing knotted or balled up When balled up the load will bounce causing the dr...

Страница 19: ...he purchase date and the complete model and serial number of your appliance This information will help us to better respond to your request If you need replacement parts If you need to order replacement parts we recommend that you use only FSP replacement parts FSP replacement parts will fit right and work right because they are made with the same precision used to build every new WHIRLPOOL applia...

Страница 20: ...ED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIO...