Whirlpool 8527813 Скачать руководство пользователя страница 5

Page 5

to dryer

shutoff valve
“open” position

gas supply
line

I.

If rigid

pipe is used
as a gas supply line, a
combination of pipe fittings must
be used to obtain an in-line
connection to the dryer.

J.

For ease of installation,

operation and servicing, adequate
space should be provided around
the dryer.

K.

A 1/8-inch NPT plugged

tapping, accessible for test gauge
connection, must be installed
immediately upstream of the gas
supply connection to the dryer. 

The dryer must be disconnected from
the gas supply piping system during
any pressure testing of the system at
test pressures in excess of 1/2 psig.

The dryer must be isolated from the gas
supply piping system by closing the
equipment shut-off valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psi (3,45 kPa)

Electrical

requirements

C.

Check that dryer is equipped

with the correct burner for the
particular type of gas used. Burner
information can be found on the
serial/rating plate in the door well of
the appliance. If this information does
not agree with the type of gas
available, see your dealer.

D.

This dryer is equipped for use

with NATURAL GAS. It is certified by
CSA International for L.P. (propane
and butane) gases with appropriate
conversion. No attempt shall be
made to convert the appliance from
the gas specified on the serial/rating
plate for use with a different gas
without consulting the serving gas
supplier. 

Conversion must be done by

a qualified service technician. Gas
conversion kit part numbers are listed
on the gas valve burner base.

E.

Provide a 

rigid gas supply line 

of

1/2-inch IPS pipe or 1/2-inch
approved tubing to the dryer
location. If the total length of the
supply line is more than 20 feet 
(6.1 m), larger tubing will be needed.
Pipe-joint compounds suitable for use
with L.P. gas should be used.

F.

The supply line shall be equipped

with a shutoff valve installed within 
6 ft. (1.8 m) of dryer in accordance
with the National Fuel Gas Code,
ANSI Z223.1 — latest edition*. This
valve should be located in the same
room as the dryer and should be in a
location that allows ease of opening
and closing. Do Not block access to
the shutoff valve.

G.

If the dryer is installed in a

confined area such as a bathroom or
closet, provision must be made for
enough air for combustion and
ventilation. (Check governing codes
and ordinances. or refer to the
section of this instruction covering
recessed and closet installations.)

H.

If local codes and ordinances

permit, it is recommended that a new
flexible gas connector, design-
certified by the AGA or CSA, be used
for connecting the dryer to the gas
supply line. (The gas pipes which
extend through the rear of the dryer
are 3/8-inch pipe thread.)

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.

Important: Observe all governing
codes and ordinances.

3-prong ground-type
outlet 

3-prong 
ground 
plug

power
supply cord

ground
prong

Copies of the standards listed above may
be obtained from:

* National Fire Protection Association

One Batterymarch Park
Quincey, Massachusetts 02269

Electrical Shock Hazard

Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or electrical
shock.

Recommended
ground method

The dryer, when installed, must be
electrically grounded in accordance
with local codes, or in the absence of
local codes, with the National
Electrical Code, ANSI/NFPA 70*.

GROUNDING INSTRUCTIONS: This
appliance must be grounded. In the
event of malfunction or breakdown,
grounding will reduce the risk of
electric shock by providing a path of
least resistance for electric current.

The power supply cord plug must be
plugged into an appropriate outlet
that is properly installed and
grounded in accordance with all
local codes and ordinances. 

WARNING - Improper connection of
the equipment-grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded. Do not modify the plug
provided with the appliance - if it will
not fit the outlet, have a proper outlet
installed by a qualified electrician.

WARNING

A 120-volt, 60-Hz, AC-only, 15- or 
20-ampere fused electrical supply is
required. A time-delay fuse or circuit
breaker is recommended. 

It is recommended that a separate
circuit serving only this appliance be
provided.

Содержание 8527813

Страница 1: ...ner Owner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use COMMERCIAL STACKED DRYER GAS Part No 8527813 COMMERCIAL LAUNDRY PRODUCTS www whirlpool com 120 volt 60 Hz ELECTRIC 120 240 volt 60 Hz Actual unit may or may not contain windows in doors depending on model ...

Страница 2: ...t to outdoors Dryer must be exhausted outdoors Note The dryer must not be installed in an area where it will be exposed to water and or weather It is your responsibility to If installing a GAS dryer FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire elect...

Страница 3: ...drive lug is in place 6 Turn cam until V shaped notch lines up with ratchet tooth 7 Press cam down in place on motor shaft Make sure that V shaped notch clears the ratchet tooth 8 Reattach the timer bracket assembly then tighten the screws 9 Repeat steps for other timer 10 Close and lock the control panel Exhaust requirements Do not use non metal flexible vent metal vent that is smaller than four ...

Страница 4: ...f checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than the CFM of all the dryers in the room Back draft Damper Kits Part No 3391910 are available from your Whirlpool dealer and should be installed in each dryer s exhaust vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main ex...

Страница 5: ...ss to the shutoff valve G If the dryer is installed in a confined area such as a bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and ordinances or refer to the section of this instruction covering recessed and closet installations H If local codes and ordinances permit it is recommended that a new flexible gas connector design certified...

Страница 6: ...If the burner does not ignite and you can feel no heat inside the dryer shut off dryer for five minutes Check that all supply valve controls are in ON position and that the electrical cord is plugged in Repeat five minute test 18 If drying time is too long make sure lint screen is clean With dryer in laundry area 11 Open the shutoff valve in the gas supply line Excessive Weight Hazard Use two or m...

Страница 7: ...sm from inside the control panel using the 3 16 bolt and washer included with the slide mechanism Install coin box 8 Repeat Steps 6 and 7 for the other coin slide mechanism Close control panel 6 Open control panel and rest it on the bottom edge of the opening Attach slide extension with flange pointing down to one of the coin slide mechanisms Insert the coin slide mechanism through the opening to ...

Страница 8: ...elief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock Fire Hazard Use 10 gauge sol...

Страница 9: ...n screw 8 Connect the other wires to outer terminal block screws Tighten screws 6 Connect the ground wire bare of the power supply cable to the external ground conductor screw Tighten screw 9 Tighten strain relief screws 10 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 9 Tighten strain relief screws 10 Insert tab of terminal block cover into slo...

Страница 10: ...al wire 4 Loosen or remove center terminal block screw 7 Tighten strain relief screws 8 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 6 Place the hooked ends of the other power supply cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten screws 5 Place the hooked end of the neutral wire white or...

Страница 11: ...is recommended that a qualified electrician determine that the ground path is adequate 10 To exhaust dryer see Exhaust requirements Pages 3 4 Connect exhaust vent to dryer exhaust outlet and exhaust hood using 4 10 2 cm clamps Use caulking to seal exterior wall opening around exhaust hood 11 Carefully move dryer into final position Place level on top of the dryers or collar first side to side then...

Страница 12: ... gas pipe All models Make sure leveling legs are secure in dryer base Tape dryer door lint screen and end of gas pipe Electric dryer models Shut off electrical supply to dryer Disconnect the power supply cord or cable from the dryer terminal block Maintenance instructions Clean lint screen after each cycle Keep dryer area clear and free from combustible materials gasoline and other flammable vapor...

Отзывы: