![Whirlpool 8177893 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/whirlpool/8177893/8177893_manual_436283020.webp)
- 16 -
2.
Turn one of the cooktop burner valves to
the LITE position.
4.
Touch the test leads to the J1 connector at
terminals 4 (white) and 9 (red). The AC
voltmeter should indicate 120 VAC. If not,
check the ignition switch and the main
wiring harness.
3.
Touch the test leads to the J1 connector at
terminals 4 (white) and 10 (black). The AC
voltmeter should indicate 120 VAC. If not,
check for the proper voltage at the power
supply outlet, and check the main wiring
harness.
J1 Connector
Cooktop Function
1.
Set the voltmeter to read 120 VAC.
4 (white)
10 (black)
J1 Connector
4 (white)
9 (red)
J1 Connector
L1
N
BK
BK
R
W
IGNITION
SWITCH
6
4 3 2 1
7
9
10
TOP BURNERS GND
10-PIN CONNECTOR
J1
DIRECT SPARK
IGNITION CONTROL
Cooktop Strip Circuit
Содержание 8177893
Страница 1: ...JOB AID Part No 8177893 WHIRLPOOL GAS RANGE DIRECT SPARK IGNITION SYSTEM KR 28 ...
Страница 22: ... 18 NOTES ...
Страница 26: ... 22 NOTES ...