MODULAR ICEMAKER SERVICE
Specifications
Mould Heater
: 185 W, 286 ohms
Thermostat
: Close
-8
±
1.5
°
C
Open
0
±
1.5
°
C
Water Fill
: 140 ml, 7.5 seconds
Motor
: 3 Watts, 16900 Ohms
Module
: Stamped circuit, plug-
in connections
Module Test Points
Module Ohmmeter Checks (No
Power to icemaker and ejector blades in park
position)
Test
Points
Compo-
nent
Module Position Resist.
Ohms
L-H
Mould
Heater
Attached to
support
286
L-M
Motor
Disconnected
from support
16900
Test
Points
Compo-
nent
Line Voltage
0 Volts
L - N
Module
Power OK
No
power
T - H
Bi-metal Open
Closed
L - H
Heater
On
Off
L - M
Motor
On
Off
N - V
Water
valve
On
Off
Service Procedures
Cover
Prise plastic pin from right hand side of module
and remove cover.
Module, Motor and Support Assembly
Insert phillips head screwdriver in access ports
in module and remove both screws. Disconnect
shut-off, pull mould from support assembly
Shut-off Arm
Pull out from support. When reassembling
insert to full depth.
Mould and Heater
Remove module, motor and support assembly.
Bi-metal
Remove module and support assembly. Pull
out retaining clips with bi-metal.
Fill Cup
Remove motor, module and support assembly,
remove ejector blades and shut-off arm. Pull
cup from mould.
Ejector Blades and Stripper
Remove module, motor, support assembly.
When reinstalling ejector blades, align “D”
coupling with module cam.
Water Level Adjustment
Turning the screw clockwise decreases the
water fill.
•
1/2 turn equals 20 ml or 1.2 seconds
•
full turn equals 40 ml or 2.4 seconds
•
Maximum adjustment is one full turn in
either direction. Additional rotation could
damage the module.
N
M
H
T
L
V
Remove 3
securing
screws