background image

WHIRLPOOL CONSUMER SERVICES                    

Model 6ADP2956 IXM

                                                                                                                                                                  

November 2001

Copyright  ©  2001 Whirlpool (Australia) Pty. Limited
All rights strictly reserved.  Reproduction or issue to third parties in any form whatsoever is not
permitted without written authority of Whirlpool (Australia) Pty. Limited
Whirlpool is a registered trademark of Whirlpool U.S.A.

This documentation is intended only for qualified technicians who possess the required qualifications and are
aware of the regulatory requirements applicable to servicing electrical appliances.

Whirlpool (Australia) Pty Limited

 Part No. SM4017

A. B. N. 28 003 578 023

WHIRLPOOL AUSTRALASIA

CONSUMER SERVICES

SERVICE MANUAL

DISHWASHER

Model 6ADP2956 IXM

Version 8542 956 53540

Содержание 6ADP2956 IXM - SERVICE

Страница 1: ...lpool Australia Pty Limited Whirlpool is a registered trademark of Whirlpool U S A This documentation is intended only for qualified technicians who possess the required qualifications and are aware of the regulatory requirements applicable to servicing electrical appliances Whirlpool Australia Pty Limited Part No SM4017 A B N 28 003 578 023 WHIRLPOOL AUSTRALASIA CONSUMER SERVICES SERVICE MANUAL D...

Страница 2: ...WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 2 of 19 BLANK PAGE ...

Страница 3: ...XPLODED VIEW CABINET 6 EXPLODED VIEW DOOR AND CONTROL PANEL 7 SPARE PARTS LIST 8 11 PROGRAMME CHART 12 CIRCUIT DIAGRAM 13 TEST PROGRAMME 14 PROCEDURE FOR DIAGNOSTIC SERVICE TEST PROGRAMME 14 15 PASSIVE TEST PROGRAMME 15 FAULT DIAGNOSIS 16 17 ACTIVE TEST PROGRAMME 18 CONTROL BOARD TEST POINTS 19 ...

Страница 4: ...e wash Main wash Drying End Electrical Data Base Data Voltage 230 240 V Frequency 50 Hz Total power 2 4 kW Fuse 10 A Motors Spray Pump Motor Voltage 230 240 V Power consumption 160 W HI in series with cap 81 HA 44 Capacitor 4 µF Drain Pump Motor Voltage 230 240 V Input 30 W Resistance 146 Drying Fan Motor Voltage 230 240 V Resistance 141 Total Air Volume 900 l min Water Pressure Temperature Inlet ...

Страница 5: ...vels Measuring Water Level Remove the coarse sieve place end of a ruler in the bottom of the sump to measure the depth of the water Water Quantities Normal Programme 6a Back Rinse x3 1 0 litre 68mm Prewash 4 8 litres 122mm Prewash Zone wash 4 0 litres 120mm Main Wash 4 5 litres 121mm Main wash Zone washing 3 5 litres 117mm Intermediate rinse1 4 0 litres 120mm Intermediate rinse1 Zone washing 3 5 l...

Страница 6: ...WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 6 of 19 EXPLODED VIEW CABINET ...

Страница 7: ...WHIRLPOOL CONSUMER SERVICES Model 6ADP2956 IXM Page 7 of 19 EXPLODED VIEW DOOR AND CONTROL PANEL ...

Страница 8: ...5 0 4812 466 48051 Insulation 103 0 4812 440 19453 Door outer black 120 0 4812 440 19456 Door inner 120 1 4812 440 18969 Batten 130 0 4812 417 58373 Door lock complete 131 0 4812 401 18416 Hook lock 175 0 4812 310 18309 Trim ornamental left black 175 1 4812 310 18308 Trim ornamental right black 175 2 4812 310 18311 Trim ornamental lower black 191 0 4812 466 68564 Gasket door 191 3 4812 466 68533 G...

Страница 9: ...75 Button black 332 2 4812 410 28672 Button black 350 1 4812 440 19968 Window black 350 2 4812 381 28047 Lens 400 0 4812 361 58126 Motor spray pump complete 405 0 4812 360 18371 Spray pump 405 1 4819 515 28158 Gasket 420 0 4812 121 18132 Capacitor 421 0 4812 121 18161 Interference filter 430 0 4812 360 18357 Pump draining 430 1 4812 466 68506 Shaft seal 442 0 4812 361 18196 Blower complete 450 0 4...

Страница 10: ...5 Gasket 716 2 4812 462 78994 Cover 721 1 4812 360 68061 Spray arm lower complete 721 2 4812 466 68491 Gasket 25x2 3B 721 3 4812 466 68558 Gasket 30x3 0 721 4 4812 440 19455 Flange 722 0 4812 360 68044 Spray arm upper 722 2 4812 360 68056 Hub upper straight complete 723 0 4812 360 68049 Spray arm ceiling 723 1 4819 310 39831 Kit 726 0 4812 530 28786 Tube 726 1 4812 530 28787 Tube 726 2 4812 505 18...

Страница 11: ...812 530 58093 Gasket 791 4 4812 466 68503 Gasket 791 5 4812 466 68504 Gasket 794 1 4819 530 58032 Gasket 20x2 5 901 0 4822 401 10492 Clamp hose 14 24 mm 901 1 4812 401 18424 Strap 050 0 901 2 4812 401 18157 Strap 32 50 9 C61 901 7 4812 401 18427 Strap 031 6 904 2 4812 462 79657 Cover black 3 5x5 904 4 4812 462 79659 Threaded cap 910 1 4812 502 18394 Screw 3 5x14 H 910 2 4812 502 18363 Screw 4 0x12...

Страница 12: ...nsor programmes only d drain depends on soil level f water fill if d water has drained h heat to 40 55 70 C depends on soil level r Rinsing time up to 12 min depends on soil level Sensor failure is only indicated in active test programme Spray time Washing 7 to 25 min Rinsing 4 to 6 5 min On 3b drying time is 2 min ...

Страница 13: ...lter L S6 Water leakage switdl L Line MS Main switch NTC Thermostat temp sensor N Neutral OWI Water indicator optical RE2 Heating relay RR RA Reed relay rinse aid SPM Spray pump motor THS1 Safety thermostat THS2 Fuse TBL Power supply terminal TL Winding protective contact UB User board VW Ventilator fan VvV1 Water inlet valve WI Water indicator ZW Zone washing 00 black 66 blue 08 grey 99 white Con...

Страница 14: ...art button lamp flashes seven times one sec break repeat Water level F8 Start button lamp flashes eight times one sec break repeat Continuous water fill F9 Start button lamp flashes nine times one sec break repeat Rinse aid low Red light on This does not prevent the machine from operating NOTE The machine will not store Fault Code F6 located during normal operation only during the active test Ther...

Страница 15: ...nts from the control board can only be made with the component connected Do not attempt to measure open circuit voltage output from the control board PASSIVE TEST PROGRAMME Passive test programme will indicate the mode of Start failure If there is no failure the test programme will result in the four programme progress lights in the display panel flashing sequentially Starting the Passive Test Pro...

Страница 16: ...ween sensor and control board are broken F1 NTC Negative Temperature Co efficient of Resistance Device Temperature is outside normal range 3 C to 85 C Temperature inside the wash chamber is over 85 C The device is either open circuit or short circuit F2 Water Leakage Water is in drip tray Float switch LS6 operates closes the water inlet valve and turns on the drain pump until the water Indicator W...

Страница 17: ...s than 10 impulses in 10 seconds Water inlet control cock closed Water inlet hose blocked or kinked Water inlet valve WV1 blocked or defective Flow Meter FM defective Water indicator defective F8 Water Level Failure Spray pump motor is energised and water indicator switches to low level more than 20 times in two minutes Water indicator defective switch should operate when machine contains approxim...

Страница 18: ...approximately 4 minutes The active test programme runs to the point of failure then stops If there is no failure the test programmes runs to the end To exit the test programme press the START button for more than three seconds An empty rinse aid container will not cause the test programme to stop only illuminate the red LED Zone Wash Valve on results in no water spraying from the centre spray arm ...

Страница 19: ...gue voltage T3 Digital signal T0 T3 T2 T1 Control Board A voltmeter with a high input impedance is required to measure the control board voltages The degree of agreement between the measured voltage and the nominated voltage will be dependent on the accuracy of the voltmeter Test Point T0 to T1 Communication between control board and display board Operated Push Button Voltage V dc All off 5 24 ZW ...

Отзывы: