background image

S E R V I C E

Whirlpool Europe

6ADG 952/3 WHM

13.12.2000 / Page 3

Customer Service

8542 952 53410

Doc. No: 4812 718 15955

Technical data

Flow rates / Inlet volume

Flow meter (at 0.3 bar
= quantity 1.1 l/min)

208

lmp/l

Spray pump

~ 70

l/min

Drain pump

16

l/min

Pump height max.

1.1

m

Inlet valve

4.5

l/min

Valve for Zone washing

30

l/min

Spray arm lower

~ 33

l/min

Sprayarm upper

~ 27

l/min

Ceiling rotor

~ 10

l/min

Electrical data

Base data

Voltage

220/230

V

Frequency

50

Hz

Total power

2.0-2.2

kW

Fuse

10

A

Motor

Spray pump motor

Voltage

220/230

V

Power consumption

160

W

HI

81

HA

44

Capacitor

4

µ

 F

Drain pump motor

Voltage

220/240

V

Power consumption

30

W

Resistance

146

Heating

1 Element system

Voltage

220/230

V

Power consumption

1.87/2.04 kW

Resistance

24.5

Heating speed

~ 2.0

˚C/min

Temperature on surface

~ 115

˚C

Safety thermostat
self reset

85

˚C

Potentiometer

Points of meassurement: 1(black) to 2 (middle)
Position 0

0.0

k

Position 1

0.5

k

Position 2

1.0

k

Position 3

1.4

k

Position 4

1.8

k

Position 5

2.3

k

Position 6

2.6

k

Water valves

Single valve at inlet hose

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

3.76

k

Valve for zone washing

Voltage

220-240

V

Frequency

50/60

Hz

Resistance

4

k

Coil of dispenser

Voltage

220/240

V

Frequency

50/60

Hz

Resistance

1.5

k

Reedcontact

flow meter
rinse aid control

NTC

20 ˚C

58.1

k

25 ˚C

47.1

k

30 ˚C

38.2

k

40 ˚C

25.4

k

50 ˚C

17.2

k

60 ˚C

11.8

k

70 ˚C

8.3

k

80 ˚C

6

k

85 ˚C

4

k

Accesory

If you need spare parts apart from
the spare part list have a look
in the Service Bulletin 4812 718 40084.

Содержание 6ADG 952/3 WHM

Страница 1: ...Exploded view 6 7 Circuit diagram 8 Program diagram 9 Text Legend 10 16 Family Global A5 Service Manual Dishwasher integratable 6ADG 952 3 WHM 6ADG 952 3 WHM This documentation is only intended for qualified technicians who are aware of the respec tive safety regulations Date 13 12 2000 Subject to modification Document No 4812 718 15955 ...

Страница 2: ...am information Start indicator Volume normal program Water Volume Level Regeneration 0 3 l 15 mm Back rinse 3x 1 0 l 68 mm Prewash 4 8 l 122 mm Prewash Zone washing 4 0 l 120 mm Main wash 4 5 l 121 mm Main wash Zone washing 3 5 l 117 mm Intermediate rinse 1 4 0 l 120 mm Intermediate rinse 1 Zone washing 3 5 l 117 mm Intermediate rinse 2 4 0 l 120 mm Intermediate rinse 2 Zone washing 3 5 l 117 mm C...

Страница 3: ... 1 Element system Voltage 220 230 V Power consumption 1 87 2 04 kW Resistance 24 5 Ω Heating speed 2 0 C min Temperature on surface 115 C Safety thermostat self reset 85 C Potentiometer Points of meassurement 1 black to 2 middle Position 0 0 0 kΩ Position 1 0 5 kΩ Position 2 1 0 kΩ Position 3 1 4 kΩ Position 4 1 8 kΩ Position 5 2 3 kΩ Position 6 2 6 kΩ Water valves Single valve at inlet hose Volta...

Страница 4: ...asket adjustm cpl 265 2 4812 404 48638 Grip basket adjustment 301 0 4812 453 79762 Control panel WH 322 0 4812 453 70598 Insert panel cpl 332 5 4812 410 28556 Cap f beater 400 0 4812 361 58126 Motor spraypump cpl 405 0 4812 360 18371 Spray pump 405 1 4819 515 28158 Gasket Pos No 12NC Code Description 420 0 4812 121 18132 Capacitor 421 0 4812 121 18161 Interf filter 430 0 4812 360 18357 Pump draini...

Страница 5: ...se 10 3X3X245 791 0 4812 532 68067 Gasket 791 4 4812 466 68503 Gasket 791 5 4812 466 68504 Gasket 794 1 4819 530 58032 Gasket 20x2 5 901 0 4822 401 10492 Clamp hose 14 24 mm 901 1 4812 401 18424 Strap 050 0 901 2 4812 401 18157 Strap 32 50 9 C61 901 5 4812 401 48573 Strap 028 6 901 7 4812 401 18427 Strap 031 6 901 8 4812 401 18075 Strap 20 32 9 mm 902 1 4812 466 78015 Fastener f buildt in models 9...

Страница 6: ...S E R V I C E 13 12 2000 Page 6 6ADG 952 3 WHM Whirlpool Europe Doc No 4812 718 15955 8542 952 53410 Customer Service Exploded view ...

Страница 7: ...S E R V I C E Whirlpool Europe 6ADG 952 3 WHM 13 12 2000 Page 7 Customer Service 8542 952 53410 Doc No 4812 718 15955 Exploded view ...

Страница 8: ... LS6 Water leakage switch L Line MS Main switch NTC Thermostat temp sensor N Neutral OWI Water indicator optical PRG Plug to program RV Water hardness switch RE2 Heating relay RR SA Reed relay salt RR RA Reed relay rinsaid SAB Sprayarm blocked SPM Sprayarm motor THS1 Safety thermostat THS 2 Fuse TBL Power supply terminal TL Winding protective contact UB User board VM Fan ventilator WV1 Water inlet...

Страница 9: ...S E R V I C E Whirlpool Europe 6ADG 952 3 WHM 13 12 2000 Page 9 Customer Service 8542 952 53410 Doc No 4812 718 15955 Program diagram ...

Страница 10: ...S E R V I C E 13 12 2000 Page 10 6ADG 952 3 WHM Whirlpool Europe Doc No 4812 718 15955 8542 952 53410 Customer Service Text Legend ...

Страница 11: ...S E R V I C E Whirlpool Europe 6ADG 952 3 WHM 13 12 2000 Page 11 Customer Service 8542 952 53410 Doc No 4812 718 15955 Text Legend ...

Страница 12: ...S E R V I C E 13 12 2000 Page 12 6ADG 952 3 WHM Whirlpool Europe Doc No 4812 718 15955 8542 952 53410 Customer Service Text Legend ...

Страница 13: ...S E R V I C E Whirlpool Europe 6ADG 952 3 WHM 13 12 2000 Page 13 Customer Service 8542 952 53410 Doc No 4812 718 15955 Text Legend ...

Страница 14: ...S E R V I C E 13 12 2000 Page 14 6ADG 952 3 WHM Whirlpool Europe Doc No 4812 718 15955 8542 952 53410 Customer Service Text Legend ...

Страница 15: ...S E R V I C E Whirlpool Europe 6ADG 952 3 WHM 13 12 2000 Page 15 Customer Service 8542 952 53410 Doc No 4812 718 15955 Text Legend ...

Страница 16: ...S E R V I C E 13 12 2000 Page 16 6ADG 952 3 WHM Whirlpool Europe Doc No 4812 718 15955 8542 952 53410 Customer Service Text Legend ...

Отзывы: