8.31 FREEZER COMP. ASSY. PARTS LIST 

Loc No 

Part Code 

Description 

5622  5624  6670

65 

A2016380000 

GROMMET SOUND DEADENING- BACK 

66 

A201637000A 

GROMMET SOUND DEADENING- FRONT 

67 

A201476000A 

WEDGE ,EVAP MOUNTING- LH 

68 

A201475000D 

WEDGE ,EVAP MOUNTING- RH 

68 

A2035710000 

FOIL- EVAPORATOR WEDGE 

69 

A2013780000 

SOUND DEADENING- EVAPORATOR 

69 

A2112900000  EVAPORATOR-SPIROTECH 

1 1 1 

70 

A2036310000 

DEFROST HEATER, 110V/60HZ- TAIWAN 

72 

A201492000B 

COVER EVAP, BACK 

73 

A203627000A 

FAN MOTOR- EXPORT, 110V/60HZ 

75 

A201493000H 

COVER EVAP, FRONT 

 

75 

A2036600000 

COVER EVAP, FRONT- EXPORT 

 

 

76 

A201494000C 

DAMPER -FREEZER  CONTROL 

 

76 

A201495000C 

KNOB -FREEZER CONTROL 

76 

A201566000A 

DAMPER, FREEZER CONTROL- 220/250L 

 

 

78 

5319330000 

GROMMET FAN MTG 

81 

A201179000C 

BLADE -FAN, EVAPORATOR 

83 

A2036380000 

WIRING ASSY- FC 110V/60HZ 

87 

A201164000A 

GASKET- EVAP COVER ,SIDE 

88 

A2011630000 

GASKET -EVAP COVER ,TOP 

89 

A201068000J 

FREEZER FLOOR-INTEGERATED, HIPS 

89 

A2012550000 

GASKET- EVAPORATOR COVER,BOTTOM 

Содержание 5622

Страница 1: ...e of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 No Frost Refrigerator PARTS SERVICEManual Models 5622 285L 2G UL 110V QCS WHITE 5624 285L 2G UL 110V QCS S GREY 6670 220L 2G 110V 60 HZ NARSO GREY UL Kitting ...

Страница 2: ...ystem schematic layout 8 7 0 Refrigerator does not operate 9 7 0 Trouble shooting cooling system 10 7 1 Trouble shooting defrosting 11 8 10 Cabinet assembly parts diagram 12 8 11 Cabinet assembly parts list 13 8 20 Shelves part diagram 14 8 21 Shelves parts list 15 8 30 Freezer compartment parts diagram 16 8 31 Freezer compartment parts list 17 8 40 Control box parts diagram 18 8 41 Control box pa...

Страница 3: ... Unplug from the electrical outlet Earth the appliance to avoid the risk of an electric shock This may cause abnormal heating or fire hazard Do not install the refrigerator in a humid with condensation location or an unstable surface If earthling is not done it will cause break down and electric shock It may cause electric shock It may cause fire or abnormal operation which leads to injury This ma...

Страница 4: ...efrigerator This can protect against the risk of fire hazard caused by tracking and short circuit When the trace of moisture penetration is detected insulation tapping Do not store bottled food or drinks in the freezing compartment Do not put on top of the refrigerator Please wipe out foreign materials of the metal option of power plug cleanly Do not store food in unstable manner When replacing el...

Страница 5: ...tity 96Grams Depth 625mm Capacity 220L Refrigerator compartment 150L Freezer compartment 70L Thermostat Cooling Total 220L Switching values Cut in Temperature COLD 3 9 to 7 3 Deg Cen MID 2 4 to 0 9 Deg Cen WARM 0 5 to 3 9 Deg Cen Electrical Connection Switch off Temperature Voltage Frequency For every 8 hours Max Voltage 130V Power consumption Min Voltage 100V In 24 hours 1 36kwh With Control knob...

Страница 6: ...mm Depth 625mm Type R134a Quantity 96Grams Capacity 285L Thermostat Cooling Refrigerator Compartment 215L Cut in temperature Freezer Compartment 70L COLD 1 7 to 1 7 Deg Cen Total 285L MID 2 0 to3 6 Deg Cen WARM 2 8 to 6 2 Deg Cen Electrical Connection Voltage Switch off Frequency For every 8 hours Maximum 130V Minimum 100V Power consumption In 24 hours 1 4392 Kwh With control knobs in Mid Position...

Страница 7: ...This document is only intended for qualified technicians who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 4 110 130 V ...

Страница 8: ...s who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 8 6 0 Sealed System Schematic Layout Evaporator Condenser Foamed in three sides Heat Loop Foamed Drier Compressor Precooler ...

Страница 9: ...in at the wall outlet Does the compressor operate Make sure that the thermostat is electrically connected Replace the defective part Check the defrost timer Check the PTC relay Check the over load protector Check the Condensor The compressor is defective Check for abnormalities Check the electrical connection The compressor is defective The freezing cycle has a problem The compressor is operated f...

Страница 10: ...ost on the suction pipe The condenser is overheated The refrigerator is not easily get cooled The condenser is cold The compressor surface temperature is high Moisture in the refrigerant cause the malfunction Foreign substances hamper the cooling cycle The compressor is defective To much refrigerant Refrigerant licks Slight r efrigerant leakage causes partial cooling with frost on the EVAP Replace...

Страница 11: ...ace the temperature fuse Replace the bimetal thermometer Replace the defrost heater Y es Y es Y es No No No No No Does not cooling fan operate Is the freezer defrosted normally Is the door close properly Is the door stopper hinge normal Is too much food stored in the freezer compartment cooling fan motor Check the door switch Check the T emperature fuse Bimetal thermometer Defrost heater Defrost t...

Страница 12: ...This document is only intended for qualified technicians who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 9 ...

Страница 13: ...5070B END CAP FC TOP GREY 1 1 12 A2035270000 GASKET FC DOOR SERVICE 1 1 1 14 A201156200D STOP DOOR FC RH SWING WHITE 1 14 A2011560700 STOP DOOR FC RH SWING GREY 1 1 16 A201198000A SUPPORT DOOR 1 1 1 18 9400140000 HOLE PLUG 1 1 1 18 A2016462000 HOLE PLUG PRESSFIT WHITE 1 18 A2011070700 FILLER WRAPPER CORNER GREY 1 1 18 A201646070A HOLE PLUG PRESSFIT GREY 1 1 20 A2080600700 DOOR ASSEMBLY RC FIP 220L...

Страница 14: ...This document is only intended for qualified technicians who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 11 ...

Страница 15: ... FREEZE 1 1 1 44 A2083020000 WIRE SHELF ASSY DOOR COOLING INTELCOOL 1 45 A201013000G DOOR CHILLER 1 1 46 A203793000B SHELF RC SAN 2 2 1 47 A2037950000 SHELF BACK TRIPLE SAN 1 1 1 48 A203794000A SHELF FRONT TRIPLE SAN 1 1 1 49 A201036000K COVER CRISPER 1 1 49 A201207000H COVER CRISPER 1 50 A201206000H CRISPER PAN 1 1 1 51 A201178000B SLIDE HUMIDITY CONTROL BLUE 1 1 1 52 57 A201391000C SHELF FLIP UP...

Страница 16: ...This document is only intended for qualified technicians who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 13 ...

Страница 17: ...G EVAPORATOR 1 1 1 69 A2112900000 EVAPORATOR SPIROTECH 1 1 1 70 A2036310000 DEFROST HEATER 110V 60HZ TAIWAN 1 1 1 72 A201492000B COVER EVAP BACK 1 1 1 73 A203627000A FAN MOTOR EXPORT 110V 60HZ 1 1 1 75 A201493000H COVER EVAP FRONT 1 1 75 A2036600000 COVER EVAP FRONT EXPORT 1 76 A201494000C DAMPER FREEZER CONTROL 1 1 76 A201495000C KNOB FREEZER CONTROL 1 1 1 76 A201566000A DAMPER FREEZER CONTROL 22...

Страница 18: ...This document is only intended for qualified technicians who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 15 ...

Страница 19: ...5L SIEBE 1 1 91 A2113830000 WIRING ASSY CONT BOX PUERTORICO NON BAT 1 1 1 92 A2111090000 DEFROST TIMER PARAGON 115V 60HZ 1 1 1 93 A2013960000 BULB E14 110V SUNSHINE KOREA 1 1 1 94 A2014490000 SOCKET ASSY LIGHT 1 1 1 95 A201593000G CONTROL BOX 285L NEW GRAPHICS 1 1 95 A2036980000 CONTROL BOX 220L HK RETAIL 1 96 A201135000D KNOB THERMOSTAT 1 1 96 A2036590000 KNOB CONTROL RC EXPORT 1 97 A201037000A L...

Страница 20: ...This document is only intended for qualified technicians who are aware of the respective safety regulations Revised on 25 03 2003 Subject to modification Document No WOI GNF 2003 003 Page 17 ...

Страница 21: ...0A SHIM MOUNTING CLIP COMPRESSOR 1 1 1 122 A2072080000 TRAY EVAPORATING QB51 1 1 1 8 6 Packing and Accessories spares Part Code Description 5622 5624 6670 2153908000 GROMMET HEAT EXCH 1 1 1 97918330000 BI METAL CLIP 1 1 1 A201030000E COVER UNIT MTG 1 1 1 A201139000A TRAY EGG 1 1 1 A2011660000 FOIL EVAP COVER 1 1 1 A201197000C POST CORNER BACK 1 1 A201437000A PUSHNUT 1 1 1 A201458000F POLYBAG 285L ...

Страница 22: ... 1 1 A208171000A ICE COLLECTOR 1 1 1 A2081860000 SUPPORT BUSH ICE TWISTER 1 1 1 A208203000A CUSHION SHELF PIPE DOOR COOLING 1 A2082050000 AIR DIRECTOR ICE TWISTER 1 1 1 A208211000B HOUSING CUSHION DOOR COOLING 1 A208213000A SHELF DUCT RH DOOR COOLING 1 1 1 A208214000A SHELF DUCT LH DOOR COOLING 1 1 1 A208222000A SHELF DUCT PIPE DOOR COOLING 1 1 1 A2082230000 PLUG SHELF PIPE DOOR COOLING 1 1 1 A208...

Отзывы: