background image

Содержание 3402328

Страница 1: ...Stacked Dryers Hz Models Instructions Part No 3402328 ...

Страница 2: ...ce agency or the gas suppller J Post thls warnlng In a promlnent locatlon It is recommended that the operator post in a prominent location instructions for the customer s use in the event that the customer smells gas This information should be obtained from your local gas supplier Page 2 Protectlon from weather Proper operation requires temperatures above 7 C 45 F Important Observe all governing c...

Страница 3: ... 4 reduction of the burner B T U rating shown on the model serial rating plate is required for each 300 m 1 ooO foot increase in elevation For assistance when converting to other gas types and or installing above 3000 m 10 000 feet elevation contact your local service company C n Check that dryers are equipped with the correct burner for the particular type of gas used Burner information will be f...

Страница 4: ...ion covering Recessed and closet Installations Electrical reauirements a Electrlcal Shock Hazard Electrlcal ground Is required for dprs Do Not ground to a gas pipe Do Not change the power supply cord plugs If plugs will not flt outlets have proper outlets Installed by a quallfled electrlclan Do Not have a fuse In the neutral or groundlng clrcult A tuse In the neutral or groundlng clrcult could res...

Страница 5: ... exhaust The maximum length of the exhaust system depends on the type of duct the number of elbows and the type of exhaust hood The maximum length for both rigid and flexible duct is shown in the chart Thls chart applies only to lndlvldually exhausted unlts I EXHAUSTHOOD TYPE E i2 9 s IQ2all 4 l I 12cm F WIMUM LENGTH OF 10 2 cm 4 inch DIAMEIERRIGID MEIAL DUC 0 13 1m 43 12 5m 41 11 0m 36 1 10 1m 33...

Страница 6: ...ust To connect exhaust duct straight out the back Attach exhaust duct to each dryer duct Then connect exhaust ducts to exhaust hoods or main exhaust Use duct tape to seal all joints To connect exhaust duct to the right left or bottom Use one of the following kits to convert the dryers Follow kit instructions to avoid operating problems Exhaust Kit No 279818 White Exhaust Kit No 279819 Almond Reces...

Страница 7: ...To than e to a 30 or 6 minute timing cam Electrlcal Shock Hazard Disconnect both power supply cords betore changing timer cams Failure to tallow thls lnstructlon could result In death or serlous Injury Each dryer is equipped with a 45 minute tlmer cam that provides 45 minutes of drying time when activated by the coin slide You can install the 30 minute or 60 minute timing cam shipped with each dry...

Страница 8: ...e drums thoroughly with a damp cloth 3 Install coin vaults and locks not supplied into meter case openings 4 Install control panel lock and key not supplied 5 If you wish to change the 45 minute dryer timing cams to either 30 or 60 minute timing cams see To change to a 30 or 60 minute timlng cam Pages 7 and 8 Complete all of the steps given in that section before going to Step 6 Open control panel...

Страница 9: ...dboard to protect rloor coverlng Move unit to its permanent location 15 Turn one dryer on to remove air from the gas supply line Using a full heat cycle not the air cycle let the dryer run for at least five minutes If the burner does not ignite and you can feel no heat inside the dryer shut off the dryer for five minutes Check that all supply valve controls are In ON position and that the power su...

Страница 10: ......

Страница 11: ... off electrical supply to dryers l Disconnect power supply cords and tape securely to dryer l Shut off the gas supply valves in the gas supply line l Disconnect gas pipe and fittings from dryer and cap the gas supply line Tape end of dryer gas pipes l Tape the drums to the front panel l Tape doors to cabinet l Adjust leveling legs all the way in Before installing dryers in a new location check wit...

Страница 12: ...Part No 3402328 0 1995 Whirlpool Corporation Prepared by Whirlpool Corporation Benton Harbor Michigan 49022 Printed in U S A ...