Cabinet Dimensions

*For non-vented (recirculating) installations

IMPORTANT:

Minimum distance “X”: 24" (61.0 cm) from electric cooking 
surface.
Minimum distance “X”: 27" (68.6 cm) from gas cooking 
surfaces.
Suggested maximum distance “X”: 36" (91.4 cm)

The chimneys can be adjusted for different ceiling heights. 
See the following chart.

NOTE: 

The range hood chimneys are adjustable and designed to 

meet varying ceiling or soffit heights depending on the distance 
“X” between the bottom of the range hood and the cooking 
surface. For higher ceilings, a Stainless Steel Chimney Extension 
Kit Part Number W10337357 is available from your dealer or an 
authorized parts distributor. The chimney extension replaces the 
chimney shipped with the range hood.

Venting Requirements

(vented models only)

Vent system must terminate to the outdoors except for 
non-vented (recirculating) installations.

Do not terminate the vent system in an attic or other 
enclosed area.

Do not use 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended. 
Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should 
be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight 
vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall 
cap has a damper, do not use the damper supplied with 
the range hood.

Use caulking to seal exterior wall or roof opening around 
the cap.

The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.

The break should be as close as possible to where the vent 
system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of 
air movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in 
your area.

Venting Methods

This canopy hood is factory set for venting through the roof 
or wall.

A 6" (15.2 cm) round vent system is needed for installation 
(not included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE:

 Flexible vent is not recommended. Flexible vent creates 

back pressure and air turbulence that greatly reduce 
performance.

Vent system can terminate either through the roof or wall. 
To vent through a wall, a 90° elbow is needed.

Rear Discharge

A 90° elbow may be installed immediately above the hood.

Vented Installations

Min. ceiling height

Max. ceiling height

Electric cooking 
surface

7' 

5

" (2.26 m)

9' 

2

" (2.79 m)

Gas cooking 
surface

7' 

8

" (2.34 m)

9' 

2

" (2.79 m)

Non-vented (recirculating) Installations

Min. ceiling height

Max. ceiling height

Electric cooking 
surface

7' 

5

" (2.26 m)

9' 

6

" (2.9 m)

Gas cooking 
surface

7' 

8

" (2.34 m)

9' 

6

" (2.9 m)

7

¹⁄₄

" (18.4 cm)

6⁵⁄₈

" (16.8 cm)

2" (5.1 cm) min.
6" (15.2 cm) min.*

Centerline

Side

cabinet

Side

cabinet

Vent and power

supply cable

entry location

Cooking surface

30" (76.2 cm)

15" (38.1 cm)

7

³⁄₈

" (18.7 cm)

“X”

bottom of 

canopy 

to cooking 

surface

Содержание 30" WALL-MOUNT CANOPY RANGEHOOD

Страница 1: ...ite at www whirlpool com or www whirlpool ca HOTTE DE CUISINIÈRE CONFIGURÉE EN ÎLOT À MONTAGE MURAL 30 76 2 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composez le 1 800 807 6777 ou visitez notre site web à www whirlpool ca Table of Contents Table des matières 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE...

Страница 2: ...e 24 ENTRETIEN DE LA HOTTE 25 Nettoyage 25 SCHÉMA DE CÂBLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 28 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can h...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Страница 4: ...Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions tha...

Страница 5: ...o seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should b...

Страница 6: ...2169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or tools designed and UL listed...

Страница 7: ...screw head to slide range hood into place For wall anchors install the 10 x 60 mm wall anchors and install the 5 4 x 75 mm screws into the wall anchors Tighten until the wall anchors are secure Back the screws out 6 4 mm Vent Cover Support Bracket Installation Installations using telescoping upper and lower vent cover assembly 1 Position vent cover bracket on wall about 3 0 mm away from the ceilin...

Страница 8: ...recirculating installations only 1 Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit 2 Measure from the bottom of the air deflector to the bottom of the hood outlet 3 Cut the duct to the measured size X 4 Remove the air deflector 5 Slide the duct onto the bottom of the air deflector 6 Place the assembled air deflector and duct over th...

Страница 9: ... be reversed to hide slots Complete Installation 1 For non vented recirculating installations only install charcoal filters over the grease filters using the clips provided in the kit See the Range Hood Care section 2 Install metal filters See the Range Hood Care section 3 Check the operation of the range hood blower and light See the Range Hood Use section NOTE To get the most efficient use from ...

Страница 10: ... On Off light button controls both lights Press once for On and again for Off Operating the blower The Blower Speed buttons turn the blower On and control the blower speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button Press the Blower Off button a second time to turn the blower Off A Grease filter B Grease filt...

Страница 11: ... to 6 months with normal use Replace with Charcoal Filter Kit See the Assistance or Service section for information on ordering To replace charcoal filter 1 Remove metal grease filter from range hood See Metal Grease Filter in this section 2 Bend spring clips away from metal grease filter 3 Place charcoal filter into top side of metal filter 4 Bend spring clips back into place to secure the charco...

Страница 12: ... Voltage Minimum Voltage Common YL GN YL GN YL GY BK WH RD BU Motor Characteristics Power Supply Frequency Power Absorption 240 Watts 120 VAC 60 Hz Motor Resistance Ohms Blue Black Blue Gray Blue Red Blue White Room Temp 28 8 10 30 3 10 37 7 10 45 1 10 73 4 F 23 C Motor Chassis Switch Operation POSITION FUNCTION Off Lamps Low Speed Medium Speed High Speed No Connection Brown Gray L 1 Brown Yellow ...

Страница 13: ... vision etc For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada Customer eXperience Centre toll free 1 800 807 6777 or visit ...

Страница 14: ... water filters preservation solutions etc 5 Defects or damage caused by the use of non genuine Whirlpool parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by Whirlpool 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or mo...

Страница 15: ...areil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifien...

Страница 16: ...e et évacuer adéquatement les gaz veiller à acheminer l air aspiré par un conduit jusqu à l extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA ...

Страница 17: ... de 10 x 60 mm Adaptateur T10 Torx Exigences d emplacement IMPORTANT Observer les dispositions de tous les codes et règlements en vigueur Confier l installation de la hotte à un technicien qualifié C est à l installateur qu incombe la responsabilité de respecter les distances de séparation spécifiées sur la plaque signalétique de l appareil La plaque signalétique de l appareil est située derrière ...

Страница 18: ...gide est recommandé Ne pas utiliser de conduit de plastique ou en aluminium La longueur du circuit d évacuation et le nombre de coudes doivent être réduits au minimum pour fournir une bonne performance Pour un fonctionnement efficace et silencieux Ne pas utiliser plus de trois coudes à 90 Veiller à ce qu il y ait une section droite de conduit de 24 61 0 cm ou plus entre deux coudes si on doit util...

Страница 19: ...ce qui réduit considérablement la performance La sortie à l extérieur du circuit d évacuation peut se faire à travers le toit ou à travers un mur Pour la sortie à travers un mur on doit employer un raccord coudé 90 Décharge par l arrière Le raccord coudé à 90 peut être installé immédiatement au dessus de la hotte Installations sans décharge à l extérieur recyclage S il n est pas possible d évacuer...

Страница 20: ... avant de procéder à l installation de la hotte Avant d exécuter les découpages vérifier la disponibilité d un dégagement suffisant dans le plafond ou le mur pour le conduit d évacuation Avant de sélectionner la hotte à installer mesurer la hauteur libre sous plafond et la hauteur maximum disponible sous la hotte 1 Déconnecter la source de courant électrique 2 Déterminer la méthode d évacuation à ...

Страница 21: ... 3 Acheminer le câble d alimentation du domicile selon les prescriptions du Code national de l électricité des normes CSA et des codes et règlements locaux Il faut que la longueur du conduit de et des conducteurs soit suffisante depuis le tableau de distribution avec fusibles ou disjoncteurs pour réaliser le raccordement dans le boîtier de connexion de la hotte REMARQUE Ne pas remettre le système ...

Страница 22: ...électrique 2 Ôter le couvercle du boîtier de connexion 3 Ôter l opercule arrachable du boîtier de connexion et installer un serre câble de homologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile à travers le serre câble de jusque dans le boîtier de connexion A Bride de cache conduit B Vis de 2 9 x 6 5 mm C Déflecteur A Déflecteur d air B Bride pour conduit C X longueur à laquelle c...

Страница 23: ...nstallations avec décharge à l extérieur le cache conduit supérieur peut être inversé pour dissimuler les fentes Achever l installation 1 Pour les installations sans décharge à l extérieur recyclage uniquement installer les filtres à charbon sur les filtres à graisse à l aide des attaches fournies avec l ensemble Voir la section Entretien de la hotte 2 Installer les filtres métalliques Voir la sec...

Страница 24: ...e les deux lampes Appuyer une fois pour marche et une deuxième fois pour arrêt Utilisation du ventilateur Les boutons vitesse du ventilateur activent le ventilateur et contrôlent la vitesse du ventilateur et le niveau sonore pour un fonctionnement silencieux On peut modifier la vitesse à tout moment pendant le fonctionnement du ventilateur en appuyant sur le bouton de vitesse du ventilateur souhai...

Страница 25: ...harbon Voir la section Assistance ou service pour plus d informations sur le processus de commande Remplacement du filtre à charbon 1 Retirer le filtre à graisse métallique de la hotte Voir Filtre à graisse métallique dans cette section 2 Déplier les attaches à ressort pour les écarter du filtre à graisse métallique 3 Placer le filtre à charbon dans la partie supérieure du filtre métallique 4 Repl...

Страница 26: ...mum Commun JA VE JA VE JA GRIS N BL R BU Châssis à moteur BU BL JA JA MAR JA Caractéristiques du moteur Alimentation électrique Fréquence Absorption de courant 240 Watts 120 VAC 60 Hz Résistance du moteur ohms Bleu Noir Bleu Gris Bleu Rouge Bleu Blanc Temp ambiante 28 8 10 30 3 10 37 7 10 45 1 10 73 4 F 23 C Commutateur de fonctionnement POSITION FONCTION Arrêt Lampes Vitesse Basse Vitesse Moyenne...

Страница 27: ...ntion de dépannage Les techniciens de service désignés par Whirlpool sont formés pour remplir la garantie des produits et fournir un service après garantie partout au Canada Caractéristiques et spécifications sur toute notre gamme d appareils électroménagers Références aux marchands locaux Consignes d utilisation et d entretien Vente d accessoires et de pièces de rechange Pour plus d assistance Si...

Страница 28: ...6 Conversion de votre produit du gaz naturel ou du gaz de pétrole liquéfié 7 Dommages causés par accident mésusage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuvés par Whirlpool 8 Réparations aux pièces ou systèmes dans le but de rectifier un dommage ou des défauts résultant d une réparation altération ou modification non autorisée faite à l appareil 9 Déf...