Electrical Requirements

IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.

This cooktop is equipped with an electronic ignition system that 
will not operate if plugged into an outlet that is not properly 
polarized.

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this cooktop be provided.

Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 

The wiring diagrams are provided with this cooktop. See 
“Wiring Diagrams” on a separate sheet. The wiring diagrams 
are located on the left underside of the cooktop base.

Gas Supply Requirements

Observe all governing codes and ordinances. 

IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 

IMPORTANT: Leak testing of the cooktop must be conducted 
according to the manufacturer’s instructions.

Type of Gas 

Natural Gas:

This cooktop is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 

This cooktop is factory set for use with Natural gas. If 
converting to LP gas, see the “LP Gas Conversion” 
instructions provided in the package containing literature. 
The model/serial rating plate located on the underside of the 
cooktop base has information on the types of gas that can be 
used. If the types of gas listed do not include the type of gas 
available, check with the local gas supplier.

LP Gas Conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the cooktop from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See the Gas 
Conversion instructions provided in the package containing 
literature.

Gas Supply Line 

Provide a gas supply line of 

³⁄₄

" (1.9 cm) rigid pipe to the 

cooktop location. A smaller size pipe on longer runs may 
result in insufficient gas supply. Pipe-joint compounds that 
resist the action of LP gas must be used. Do not use 
TEFLON

®†

 tape. With LP gas, piping or tubing size should be 

½" minimum. Usually, LP gas suppliers determine the size 
and materials used in the system.

Flexible metal appliance connector:

If local codes permit, use a 

¹⁄₂

" or 

³⁄₄

" I.D. flexible stainless 

steel tubing gas connector, designed by CSA to connect 
the cooktop to the rigid gas supply line. 

A ½" male pipe thread is needed for connection to the 
female pipe threads of the inlet to the cooktop pressure 
regulator. 

Do not kink or damage the flexible metal tubing when 
moving the cooktop.

Rigid pipe connection: 

The rigid pipe connection requires a combination of pipe 
fittings to obtain an in-line connection to the cooktop. The 
rigid pipe must be level with the cooktop connection. All 
strains must be removed from the supply and fuel lines so 
cooktop will be level and in line.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Содержание 30"(76.2 CM)

Страница 1: ...tallation 9 SÉCURITÉ DE LA TABLE DE CUISSON 11 EXIGENCES D INSTALLATION 12 Outillage et pièces 12 Exigences d emplacement 12 Spécifications électriques 14 Spécifications de l alimentation en gaz 14 INSTRUCTIONS D INSTALLATION 16 Installation de la table de cuisson 16 Raccordement au gaz 17 Achever l installation 18 W10526090A IMPORTANT Installer Leave installation instructions with the homeowner H...

Страница 2: ...g property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can...

Страница 3: ... areas such as windows doors and strong heating vents or fans All openings in the wall or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The...

Страница 4: ... 1 cm A 36 91 4 cm B 21 53 3 cm C 3 9 7 cm D 5 13 3 cm E 15 38 7 cm E D A B C E D A B C A 30 76 2 cm on 30 models 36 91 4 cm on 36 models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet 24 61 cm minimum clearance if bottom of wood or metal cabinet is covered by not less than 0...

Страница 5: ...tructions provided in the package containing literature The model serial rating plate located on the underside of the cooktop base has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP Gas Conversion Conversion must be done by a qualified service technician No attempt shall be made to convert th...

Страница 6: ...ssure Burner Input Requirements Input ratings shown on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings should be reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada Gas Supply Pressure Testing Gas supply pressure for testing regulator must be at least 1 water column pressure above the manif...

Страница 7: ...his is the recommended location Clamping brackets can be installed on the front and back of cooktop base bottom if necessary 2 Using 2 or more people place cooktop right side up into the cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from cutout to avoid scratching the countertop 3 Remove th...

Страница 8: ...person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire No appliance below cooktop Wall oven installed below cooktop A Manifold entrance B Gas pressure regulator C Use pipe joint compound D Adapter mus...

Страница 9: ...o a draft or other adverse condition This feature is provided only as a convenience Check Operation of Surface Burners Push in and turn the surface burners control knobs to light The surface burner flame should light within 4 seconds The first time a surface burner is lighted it may take longer that 4 seconds to light because of air in the gas line Check the flame on HIGH for a blue color It shoul...

Страница 10: ... be adjusted using the adjustment screw located underneath the control knob 1 Remove the control knob from valve stem 2 Remove rubber grommet 3 Use a small flat blade screwdriver to turn the adjustment screw clockwise until tight Do not overtighten 4 Replace rubber grommet and control knob 5 Repeat for remaining burners A Adjustment screw B Knob hole knob removed C Control knob A B C ...

Страница 11: ...n décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du télé...

Страница 12: ...cement d installation de la table de cuisson doivent être scellées Respecter les dimensions indiquées pour la cavité d installation entre les placards Ces dimensions tiennent compte des valeurs minimales des dégagements de séparation Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques Une source de gaz adéquate doit être disponible Voir la sec...

Страница 13: ... distance de séparation de 24 61 0 cm ou plus si le fond du placard de métal ou de bois est protégé par une plaque de 0 6 cm ou plus de matériau résistant aux flammes recouvert d une feuille métallique d épaisseur égale ou supérieure à calibre 28 pour l acier 0 015 0 04 cm pour l acier inoxydable ou 0 024 0 06 cm pour l aluminium ou 0 020 0 05 cm pour le cuivre D Profondeur recommandée des placard...

Страница 14: ...fusible On recommande également d utiliser un fusible ou un disjoncteur temporisé Il est recommandé de raccorder la table de cuisson sur un circuit distinct exclusif à cet appareil Les systèmes d allumage électronique fonctionnent avec des limites de tension étendues mais une liaison à la terre correcte et une polarité appropriée sont nécessaires Vérifier que la prise fournit une alimentation de 1...

Страница 15: ... table de cuisson On doit veiller à ne soumettre les sections de canalisation d alimentation et de combustible à aucun effort de traction ou flexion pour que la table de cuisson soit d aplomb et correctement alignée Robinet d arrêt nécessaire La canalisation d alimentation doit comporter un robinet d arrêt manuel Le robinet d arrêt manuel doit être séparé de la table de cuisson mais doit se trouve...

Страница 16: ...nécessaire pour l installation de brides de fixation aux extrémités de la base de la table de cuisson Il s agit de l emplacement recommandé Des brides de fixation peuvent être installées à l avant et à l arrière de la partie inférieure de la base de la table de cuisson si nécessaire 2 À l aide d au moins 2 personnes placer la table de cuisson dans l ouverture en orientant la bonne surface vers le ...

Страница 17: ...national Installer un robinet d arrêt Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander à une personne qualifiée de s assurer que la pression de gaz ne dépasse pas 36 cm 14 po de la colonne d eau Par personne qualifiée on comprend le personnel autorisé de chauffage le personnel autorisé d une compagnie de gaz et le personnel d entretien au...

Страница 18: ...le de cuisson est dotée d une fonction de rallumage électronique automatique grâce à un allumeur à étincelles situé à l arrière de chaque brûleur Les brûleurs sont conçus pour s allumer à chaque rotation de valve qui laisse entrer assez de gaz pour maintenir la flamme et pour se rallumer automatiquement lorsque la flamme s est éteinte à cause d un courant d air ou d une autre circonstance défavora...

Страница 19: ...flammes stables bleues d environ 0 64 cm de hauteur S il est nécessaire de régler la taille des flammes pour le débit thermique minimum Cette table de cuisson est expédiée de l usine avec des réglages de débits thermiques minimum et maximum pour l usage au gaz naturel Pour l usage au propane le débit thermique peut être réglé à l aide de la vis de réglage située sous le bouton de commande 1 Ôter l...

Страница 20: ...W10526090A 2012 Whirlpool Corporation All rights reserved Tous droits réservés 8 12 Printed in U S A Imprimé aux É U ...

Отзывы: