IMPORTANT: The water heater should be located in 
an area where leakage of the tank or connections 
will not result in damage to the area adjacent to the 
water heater or to lower floors of the structure. Due 
to the normal corrosive action of the water, the tank 
will eventually leak after an extended period of time. 
Also any external plumbing leak, including those from 
improper installation, may cause early failure of the tank 
due to corrosion if not repaired.  If the owner/operator is 
uncomfortable with making the repair a qualified person 
should be contacted.  A suitable metal drain pan should 
be installed under the water heater as shown below, 
to help protect the property from damage which may 
occur from condensate formation or leaks in the piping 
connections or tank. The pan must limit the water level 
to a maximum depth of 1-3/4” and be two inches wider 
than the heater and piped to an adequate drain. NOTE: 
The pan must not restrict combustion air flow.

 

Locate the 

water heater near a suitable indoor drain. Outside drains 
are subject to freezing temperatures which can obstruct 
the drain line. The piping should be at least 3/4” ID and 
pitched for proper drainage. Under no circumstance will 
the manufacturer or seller of this water heater be held 
liable for any water damage which is caused by your 
failure to follow these instructions.

1 3/4” maximum

Pipe to

adequate

drain

At least 2” greater than the 

diameter of the water heater.

• 

The water heater should be located in an area not 
subject to freezing temperatures. Water heaters located 
in unconditioned spaces (i.e., attics, basements, 
etc.) may require insulation of the water piping and 
drain piping to protect against freezing. The drain and 
controls must be easily accessible for operation and 
service. Maintain proper clearances as specified on the 
data plate.

• 

Do not locate the water heater near an air-moving 
device. The operation of air-moving devices such as 
exhaust fans, ventilation systems, clothes dryers, 
fireplaces, etc., can affect the proper operation of 
the water heater. Special attention must be given to 
conditions these devices may create. Flow reversal of 
flue gases may cause an increase of carbon monoxide 
inside of the dwelling.

• 

If the water heater is located in an area that is 
subjected to lint, dirt, and oil, it may be necessary 
to periodically clean the flame-trap and pilot (see 
“External Inspection & Cleaning of the Flame-trap” and  
“Cleaning the Pilot Assembly” section).

Figure 1
Air-moving
Devices

Reverse flow
of gases

Exhaust

Fan

Clearances and Accessibility

NOTE: Minimum clearances from combustible materials 
are stated on the data plate adjacent to the gas control 
valve/thermostat of the water heater.
The water heater is certified for installation on a 
combustible floor.

• 

IMPORTANT: If installing over carpeting, the carpeting 
must be protected by a metal or wood panel beneath 
the water heater. The protective panel must extend 
beyond the full width and depth of the water heater by 
at least three inches (76.2mm) in any direction; or if in 
an alcove or closet installation, the entire floor must be 
covered by the panel. 

• 

Figure 2 may be used as a reference guide to locate 
the specific clearance locations. A minimum of 24 
inches of front clearance should be provided for 
inspection and service.

Back

Sides

Sides

Top

View

Top

to

ceiling

Vent

Front

24” minimum 

for service

Figure 2

Minimum Clearance

Locations

State of California

NOTE: The water heater must be braced, anchored, or 
strapped to avoid moving during an earthquake. Contact 
local utilities for code requirements in your area or call 
1-877-817-6750 and request instructions.

Содержание 201553

Страница 1: ...service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death INSTALLER AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO THE WATER HEATER OWNER RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE RETAIN THE ORIGINAL RECEIPT AS PROOF OF PURCHASE 6510415 W10123251 March 200...

Страница 2: ... substances WARNING This product contains a chemical known to the State of California to cause cancer birth defects or other reproductive harm This appliance can cause low level exposure to some of the substances included in the Act Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all s...

Страница 3: ...users of this water heater will need it for future reference Service to the Flame Lock Safety System should only be performed by a qualified person Examples of a qualified person include licensed plumbers authorized gas company personnel and authorized service personnel IMPORTANT The manufacturer and seller of this water heater will not be liable for any damages injuries or deaths caused by failur...

Страница 4: ... liquids or vapors have spilled or leaked in the area of the water heater leave the area immediately and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been extinguished Keep combustibles such as boxes magazines clothes etc away from the water heater area Site Location Select a location near the center of the water piping system Th...

Страница 5: ...trols must be easily accessible for operation and service Maintain proper clearances as specified on the data plate Do not locate the water heater near an air moving device The operation of air moving devices such as exhaust fans ventilation systems clothes dryers fireplaces etc can affect the proper operation of the water heater Special attention must be given to conditions these devices may crea...

Страница 6: ...ntrol valve thermostat 4 Turn the gas supply on and check for leaks Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found Figure 3 Gas Piping Manual Gas Shut off Valve Ground Joint Union 3 minimum Check with local utility for minimum height Drip leg Gas Pressure IMPORTANT The gas supply pressure must not exceed the maxi...

Страница 7: ...e is excluded from warranty coverage The following types of installation not limited to the following will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air beauty shops photo processing labs buildings with indoor pools water heaters installed in laundry hobby or craft rooms water heaters installed near chemi...

Страница 8: ... be drawn from outside of the enclosure One opening shall be within 12 inches of the top and one within 12 inches of the bottom of the enclosure as shown in Figure 4 The size of each opening free area is determined by the total BTUH input of all gas utilization equipment i e water heaters furnaces clothes dryers etc and the method by which the air is provided The BTUH input can be found on the wat...

Страница 9: ...ipment so that they are opened automatically during equipment operation Keep louvers and grilles clean and free of debris or other obstructions Direct to outdoors Vertical ducts Horizontal ducts Figure 6 Figure 7 Figure 8 Table 3 Minimum Free Area of Permanent Openings for Ventilation and Combustion Air Supply All Air from Outdoors Only Based on the total BTUH input rating for all gas utilizing eq...

Страница 10: ...isting water heater be sure to use the new draft hood supplied with the water heater Vent Pipe Size It is important that you follow the guidelines in these instructions for sizing a vent pipe system If a transition to a larger vent size is required the vent transition connection must be made at the draft hood outlet Vent Connectors 1 Type B Double Wall U L Listed Vent Pipe 2 Single Wall Vent Pipe ...

Страница 11: ...terminate with a listed cap or other roof assembly and be installed according to their manufacturer s instructions Gas vents must be supported to prevent damage joint separation and maintain clearances to combustible materials Figures 11 and 12 IMPORTANT This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases An unused chimney flue or masonry enclosure ...

Страница 12: ...r line as shown in Figure 14 These valves reduce the point of use temperature of the water by mixing cold and hot water and are readily available for use 4 If installing the water heater in a closed water system install an expansion tank in the cold water line as specified under Closed System Thermal Expansion section 5 Install a shut off valve in the cold water inlet line It should be located clo...

Страница 13: ...ain a check valve backflow preventer or water pressure reducing valve This will create a closed water system During the heating cycle of the water heater the water expands causing pressure inside the water heater to increase This may cause the temperature and pressure relief valve to discharge small quantities of hot water To prevent this it is recommended that a diaphragm type expansion tank suit...

Страница 14: ...t terminate a maximum of six inches above a floor drain or external to the building Must be capable of withstanding 250 F 121 C without distortion Must be installed to allow complete drainage of both the valve and discharge line T P Relief Valve and Pipe Insulation Some Models 1 Locate the T P Relief Valve on the water heater 2 Locate the slit running the length of the insulation 3 Spread this sli...

Страница 15: ...m the system Otherwise these bubbles will be trapped in the air handler heat exchanger coil reducing the efficiency Do not connect the water heater to any system or components previously used with non potable water heating appliances when used to supply potable water Some jurisdictions may require a backflow preventer in the incoming cold water line This may cause the temperature and pressure reli...

Страница 16: ...rized service provider Fresh air supply free of corrosive elements and flammable vapors Fresh air openings sized correctly with consideration given to the blocking effect of louvers and grilles Ductwork is the same cross sectional area as the openings Vent Pipe System Check for proper drafting at the water heater draft hood Refer to the Checking the Draft section of this manual for the test proced...

Страница 17: ...ckwise to its lowest setting WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life LIGHTING INSTRUCTIONS 7 Depress the reset button all the way in and IMMEDIATELY depress the igniter button until you hear a loud click Observe the pilot through the view port Do not release the reset button Repeat immediately if...

Страница 18: ...how a discoloration on the air intake grid and require replacement of the entire water heater Depress the gas control knob slightly and turn clockwise to OFF Do not use tools or force Turn the temperature dial clockwise to its lowest setting Turn gas control knob clockwise to PILOT WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage person...

Страница 19: ...e edges After several minutes of operation the burner screen may glow red If large flames are observed at anytime shut off unit and call a qualified person Stacking Stacking occurs when a series of short draws of hot water 3 gallons or less are taken from the water heater tank This causes increased cycling of the burner and can result in increased water temperatures at the hot water outlet An anti...

Страница 20: ...ilot flame is present and will shut off the gas supply to the main burner and the pilot burner if the flame is absent A high temperature limit switch or ECO Energy Cut Off in the tank is used to shut off the unit if the water temperature exceeds 180 F 83 C The ECO is a single use switch which if activated requires complete replacement of the entire gas control valve thermostat If the ECO should ac...

Страница 21: ...n air supplies are not obstructed Build up of soot and carbon on the main burner and pilot burner Check for a soft blue flame Leaking or damaged water and gas piping Presence of flammable or corrosive materials in the installation area Presence of combustible materials near the water heater After servicing this water heater check to make sure it is working properly See Operating Your Water Heater ...

Страница 22: ... Replacing the Pilot Assembly 1 Follow the instructions in Removing the Burner Door Assembly section to remove the assembly 2 Remove the retainer clip securing the two piece wire connector to the burner door assembly Note the orientation of the retainer clip Insert the tip of a large flat head screwdriver between the clip and the top of the two piece wire connector Carefully rotate the screwdriver...

Страница 23: ...y section 2 Use a vacuum cleaner shop vac to remove all loose debris in the combustion chamber Figure 28 Use compressed air to clear any dust or debris that may have accumulated in the flame trap 3 Reassemble following the procedure under the Replacing the Burner Door Assembly section External Inspection Cleaning of the Flame trap Although not likely to occur if debris collects on the flame trap u...

Страница 24: ...spect the viewport for damage and replace as required 3 Insert the burner door assembly into the combustion chamber and slide it completely forward Note When inserting the burner door assembly tip the burner end up slightly to ensure it engages with the burner bracket 4 Inspect the door gasket and make sure there is no fiberglass insulation between the door gasket and the combustion chamber See Fi...

Страница 25: ...rder When replacing the gas valve thread a correctly sized pipe into the inlet and use it to turn the gas valve clockwise DO NOT OVER TIGHTEN damage may result Be sure to use approved Teflon tape or pipe joint compound on the gas piping connections and fitting on the back of the gas control valve that screws into tank Be sure to remove the pilot ferrule nut from the new gas control valve thermosta...

Страница 26: ...h gas utility company SLOW HOT WATER RECOVERY 1 Insufficient air 2 Flue clogged 3 Low gas pressure 4 Improper calibration 5 Thermostat set too low 6 Water heater too small 7 Wrong piping connections 8 Wasted hot water 1 Provide ventilation to water heater Check flue way flue baffle and burner 2 Clean flue locate source and correct 3 Check with gas utility company 4 Replace thermostat 5 Turn temper...

Страница 27: ...nd orifice Is the pilot free from dirt and debris NO YES Follow the Cleaning the Pilot Assembly instructions found in this manual Is the pilot protected from cold drafts that could prevent it from lighting NO YES Eliminate any drafts See the Site Location instructions found in this manual Check the water heater for a Flammable Vapor FV event If the flame trap show signs of discoloration shut off t...

Страница 28: ... PIECE WIRE CONNECTOR WITH RETAINER CLIP 15 BURNER DOOR GASKET 16 VIEWPORT ASSEMBLY 17 THERMOCOUPLE 18 PIEZOELECTRIC IGNITER BUTTON 19 FLEXIBLE MANIFOLD TUBE REPAIR PARTS ILLUSTRATION When ordering repair parts always give the following information 1 Model serial and product number 2 Type of gas 3 Item number 4 Parts description Repair Parts List LEGEND Special anode rod see Anode Rod Water Odor s...

Страница 29: ...ntains two piece wire connector and retainer clip Item 15 Contains burner door gasket Item 16 Contains viewport Item 17 Contains thermocouple Item 18 Contains piezoelectric igniter button Item 19 Contains flexible manifold tube Item 15 Item 14 Item 16 Item 13 Item 12 Item 18 Item 17 Item 19 Alternate Igniter WHIRLPOOL FLAME LOCK DESIGN and FLAME LOCK are trademarks of Whirlpool U S A 2007 Whirlpoo...

Отзывы: