Whip Mix Corporation
361 Farmington Avenue
Louisville, KY USA 40209
Toll-Free: 800-626-5651
Phone: 502-637-1451
Fax: 502-634-4512 www.whipmix.com
MPL30101 Rev A (01/2017)
Страница 1: ...Facebow Registration Instructions Whip Mix Corporation 361 Farmington Ave P O Box 17183 Louisville KY 40217 0183 USA 502 637 1451 800 626 5651 Fax 502 634 4512 www whipmix com ...
Страница 2: ...eplacing them make sure the hole on the flat side of each is above the side arm and the plastic is seated until it touches the shoulder of the arm 2 Attach the transfer jig to the facebow and tighten thumb screw on top Figure 2 and 3 3 A rubber band may be easily positioned on the facebow to aid in its manipulation Figure 4 Note The nasion relator assembly moves left and right along the crossbar a...
Страница 3: ... is set Figure 5 The record should make a shallow registration of the maxillary cusp tips and not perforate through to the bitefork 4 Inspect the registration for any soft tissue or deep occlusal registrations It is only necessary to record the maxillary cusp tips all else should be trimmed away using a sharp Bard Parker blade Positioning the Facebow on the Patient 1 Before attempting to place the...
Страница 4: ...umbscrew of the nasion relator assembly This pressure will help to firmly seat the ear pieces into the external auditory meatus Figure 7 6 Tighten the thumbscrew on top of the facebow Figure 8 7 Support the horizontal bar with one hand and tighten the thumbscrew on the vertical rod Figure 9 8 Support the horizontal bar with one hand and tighten the thumbscrew on the horizontal rod Figure 10 9 Veri...
Страница 5: ...urchased before that date the bitefork will have a straight center shaft and the transfer jig horizontal bar will extend to the right Figure 11 For these earlier systems and when using indirect mounting of the maxillary model the incisal guide pin will need to be removed and a support bar will be needed at the top of the transfer jig Figure 12 Indirect Mounting of the Maxillary Model 1 Separate th...
Страница 6: ...rod fits securely in the transfer base Figure 16 4 Position the upper model into the bite registration and mount the maxillary model Figure 17 Note Please refer to instructions in articulator manual for mounting mandibular models Direct Mounting of the Maxillary Model 1 Slide the nasion relator assembly to the patient s left away from the center of the horizontal crossbar Loosen the center thumbsc...
Страница 7: ...ach earpiece of the facebow Figure 20 5 Allow the anterior end of the upper frame of the articulator to rest on the horizontal crossbar of the facebow Figure 21 6 Securely tighten the thumbscrew on top of the facebow 7 Because the guidance of this instrument is part of the upper frame and the facebow is in effect one piece with this fram the facebow bitefork is in fixed relation to the upper frame...
Страница 8: ...Whip Mix Corporation 361 Farmington Avenue Louisville KY USA 40209 Toll Free 800 626 5651 Phone 502 637 1451 Fax 502 634 4512 www whipmix com MPL30101 Rev A 01 2017 ...