Whelen Engineering Company WPKM1 Скачать руководство пользователя страница 4

Page 4

20 AMP FUSE
(CUSTOMER SUPPLIED)

20 AMP FUSE
(CUSTOMER SUPPLIED)

1 AMP fuse

(customer supplied)

3 AMP FUSE
(CUSTOMER SUPPLIED)

3 AMP FUSE
(CUSTOMER SUPPLIED)

WPKM1

PARK-KILL

MODULE

Red

Red

Grey

Blue

Black

Black

Yellow

Yellow

BLK

BLK

BLK

BLK

RED

RED

RED

RED

VIO

VIO

BLU

BLU

BLU

BLU

ORN

ORN

GRY

RED

WHT

YEL

VIO

GRN

BLK/WHT

BLK

BRN

BRN

YEL

YEL

GRY

GRY

WHT

WHT

PARK-KILL

(See Text

for wire color)

12 VDC

BATTERY

+

-

12 VDC

BATTERY

+

-

295HFSA1
295HFSA5
295HFSA6

295HFS2
295HFS3
295HFS4

Siren

Amplifier

Control

Head

295HFSA1
295HFSA5
296HFSA6

White/Green
Violet

Park-Kill Color

Model

5 AMP FUSE
(CUSTOMER SUPPLIED)

3 AMP FUSE
(CUSTOMER SUPPLIED)

J8

J7

J6

POWER

COMM

AUX

CTRL

BLUE

GRAY

WHITE

BLACK

SHEILD

1

1

1

BLUE

BLUE

GREEN

VIOLET

RED

BLACK

YELLOW

BROWN

AUXIN 1

RED

AUXIN 2

ORANGE

YELLOW

12 VDC

BATTERY

+

-

MPC01/
MPC02

CABLE

RS485

Red

WPKM1

PARK-KILL

MODULE

Grey

Black

Yellow

The following wiring diagrams are for use when the WPKM1 is installed with either

the MPC01 & MPC02 Multi-Purpose Controllers, or the 295HFS Series siren amplifiers

IMPORTANT! If the WPKM1 is used with
the 295HFS2, 295HFS3 or 295HFS4 series
siren, all siren functions including P.A. are
disabled when the WPKM1 is activated.

WPKM1

PARK-KILL

MODULE

Blue

White

To Neutral

Safety Switch

(see text)

(not used)

Blue

White

To Neutral

Safety Switch

(see text)

(not used)

Grey

White

To Neutral

Safety Switch

(see text)

(not used)

To +12VDC

Butt

Splice

Butt

Splice

Содержание WPKM1

Страница 1: ...al connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment simultaneously to insure that they operate free of interference from other...

Страница 2: ...UIT IS A VIOLATION OF THE FEDERAL MOTOR VEHICLE SAFETY STANDARD FOR THE THIRD BRAKE LIGHT AS WELL AS REAR BRAKE LIGHTS FUNCTIONS THAT BLACK OUT THE REAR BRAKE LIGHTS SOMETIMES CALLED BRAKE LIGHT CUT OUT MAY INTERFERE WITH THE BRAKE SHIFT LOCK MECHANISM AND CAUSE THE VEHICLE TO MOVE UNEXPECTEDLY AND DANGEROUSLY DISCONNECTING THE BRAKE LIGHTS IN ANY WAY IS AT YOUR OWN RISK AND IS NOT RECOMMENDED BY ...

Страница 3: ...icle s transmission park neutral safety switch ground signal 5 Determine which wire is the enable wire for the device to be switched Depending on the device this could be the POS the NEG wire or the control wire 6 Cut the device s enable wire Connect the YELLOW wire to the enable wire coming from the device NOTE This relay has a maximum switching current of 30 amps 7 The remaining connection is de...

Страница 4: ...D 3 AMP FUSE CUSTOMER SUPPLIED J8 J7 J6 POWER COMM AUX CTRL BLUE GRAY WHITE BLACK SHEILD 1 1 1 BLUE BLUE GREEN VIOLET RED BLACK YELLOW BROWN AUXIN 1 RED AUXIN 2 ORANGE YELLOW 12 VDC BATTERY MPC01 MPC02 CABLE RS485 Red WPKM1 PARK KILL MODULE Grey Black Yellow The following wiring diagrams are for use when the WPKM1 is installed with either the MPC01 MPC02 Multi Purpose Controllers or the 295HFS Ser...

Отзывы: