15 Amp

Fuse

Strobe Outlets

1 thru 4 (“A”)

Strobe Outlets

1 thru 4 (“B”)

2

2

2

3

3

3

1

1

1

= Control Connector

Pos.1 - No Wire

Pos.2 - Green

Pos.3 - Blue
= Pattern Selection Connector

Pos.1 - White/Red

Pos.2 - Brown

Pos.3 - White
= Power Connector

Pos.1 - Red

Pos.2 - Black

Pos.3 - Violet

(Optional)

PATTERN 1

PATTERN 2

SWITCH

(see note)

ENABLE 2A & 3A

ENABLE 1A & 4A

ENABLE 1B & 4B

ENABLE 2B & 3B

30 AMP FUSE

CUSTOMER

SUPPLIED

BATTERY

UPS158

MODEL

OUTLETS

“A

OUTLETS

“B

1

1

3

3

2

2

4

4

ALTERNATING

ALTERNATING

RED

BLK

VIO

Power

Connector

“A”

Power

Connector

“B”

Control

Connector

“A”

Control

Connector

“B”

Pattern

Selection

Connector

“A”

Pattern

Selection

Connector

“B”

RED

BLK

VIO

GRN

BLU

BRN

WHT

WHT

BRN

GRN

BLU

WHT/RED

WHT/RED

1

2

3

3

2

1

2

3

1
2

3

2

3

1

2

3

7.20”

6.00”

11.28”

.250 DIA.

(4 PLACES)

UPS158 SPECIFICATIONS:

INPUT VOLTAGE

-

13.5 VDC (26.5 VDC) ± 20%

INPUT CURRENT @ 40 Watts

-

4 AMPS (2 Lamps)

INPUT CURRENT @ 75 Watts

-

7 AMPS (4 Lamps)

INPUT CURRENT @ 115 Watts

-

11 AMPS (6 Lamps)

INPUT CURRENT @ 150 Watts

-

14 AMPS (8 Lamps)

OUTPUT POWER @ 2 LAMPS

-

40 Watts

OUTPUT POWER @ 4 LAMPS

-

75 Watts

OUTPUT POWER @ 6 LAMPS

-

115 Watts

OUTPUT POWER @ 8 LAMPS

-

150 Watts

V Ctrl (Power Connectors A & B)

-

13.5 VDC (26.5 VDC) ± 20%

I Ctrl 

-

100 ma (MAX)

V Output Ctrl 

-

13.5 VDC (26.5 VDC) ± 20%

I Output Ctrl

-

20 ma (MAX)

V Pattern Ctrl 

-

13.5 VDC (26.5 VDC) ± 20%

I Pattern Ctrl

-

5 (MAX)

COMET FLASH

®

FLASHRATE (Per Lamp)

-

75 CFPM @ 80 ms

DOUBLE FLASH
FLASHRATE (Per Lamp)

-

120 DFPM @ 80 ms

SINGLE FLASH
FLASHRATE (Per Lamp)

-

220 SFPM

ACTION FLASH

-

3 CYCLES COMET FLASH

-

6 CYCLES SINGLE FLASH

Fig. 1

Switch Operation Table

Pattern Control
Pattern 1&2 Disabled

Comet Flash Pattern

Pattern 1 Enabled

Double Flash Pattern

Pattern 2 Enabled

Single Flash Pattern

Pattern 1&2 Enabled

Action Flash Pattern

Outlet Control
Enable 1A & 4A

Outlets 1A & 4A Active

Enable 2A & 3A

Outlets 2A & 3A Active

Enable 1B & 4B

Outlets 1B & 4B Active

Enable 2B & 3B

Outlets 2B & 3B Active

Fig. 2

NOTE! The WHITE/RED wire in the Pattern 
Selection Connector provides positive voltage 
designed to be used to supply power to your 
switches. This wire is internally protected to 250 
ma. If a short circuit occurs, the circuit will inter-
rupt current flow until the short has been 
removed.

OUTLETS 1A/1B & 4A/4B = FLASH ALTERNATELY
OUTLETS 2A/2B & 3A/3B = FLASH ALTERNATELY
OUTLETS 1A/1B & 3A/3B = FLASH SIMULTANEOUSLY
OUTLETS 2A/2B & 4A/4B = FLASH SIMULTANEOUSLY

NOTE - The type of switch used is 
dependant on how  the operator wishes the 
Hi/Lo feature to function:

Latching Mode:
By apvoltage to the Violet wire for 
less than 1 sec., the power supply is 
“latched” into low power operation. The unit 
must be turned off and then back on to 
restore normal, Hi power operation. A 
momentary switch is desired for this style.

Level Mode:
Apvoltage to the Violet wire for 
more than 1 sec. holds the power supply in 
low power mode until that voltage is 
removed. A toggle switch is desired for this 
style.

Dimensions shown 

for reference only.