Page 3
15 Amp
Fuse
Strobe Outlets
1 thru 4 (“A”)
Strobe Outlets
1 thru 4 (“B”)
2
2
2
3
3
3
1
1
1
= Control Connector
Pos.1 - No Wire
Pos.2 - Green
Pos.3 - Blue
= Pattern Selection Connector
Pos.1 - White/Red
Pos.2 - Brown
Pos.3 - White
= Power Connector
Pos.1 - Red
Pos.2 - Black
Pos.3 - Violet
(Optional)
PATTERN 1
PATTERN 2
SWITCH
(see note)
ENABLE 2A & 3A
ENABLE 1A & 4A
ENABLE 1B & 4B
ENABLE 2B & 3B
30 AMP FUSE
CUSTOMER
SUPPLIED
BATTERY
UPS158
MODEL
OUTLETS
“A
”
OUTLETS
“B
”
1
1
3
3
2
2
4
4
ALTERNATING
ALTERNATING
RED
BLK
VIO
Power
Connector
“A”
Power
Connector
“B”
Control
Connector
“A”
Control
Connector
“B”
Pattern
Selection
Connector
“A”
Pattern
Selection
Connector
“B”
RED
BLK
VIO
GRN
BLU
BRN
WHT
WHT
BRN
GRN
BLU
WHT/RED
WHT/RED
1
2
3
3
2
1
2
3
1
2
3
2
3
1
2
3
7.20”
6.00”
11.28”
.250 DIA.
(4 PLACES)
UPS158 SPECIFICATIONS:
INPUT VOLTAGE
-
13.5 VDC (26.5 VDC) ± 20%
INPUT CURRENT @ 40 Watts
-
4 AMPS (2 Lamps)
INPUT CURRENT @ 75 Watts
-
7 AMPS (4 Lamps)
INPUT CURRENT @ 115 Watts
-
11 AMPS (6 Lamps)
INPUT CURRENT @ 150 Watts
-
14 AMPS (8 Lamps)
OUTPUT POWER @ 2 LAMPS
-
40 Watts
OUTPUT POWER @ 4 LAMPS
-
75 Watts
OUTPUT POWER @ 6 LAMPS
-
115 Watts
OUTPUT POWER @ 8 LAMPS
-
150 Watts
V Ctrl (Power Connectors A & B)
-
13.5 VDC (26.5 VDC) ± 20%
I Ctrl
-
100 ma (MAX)
V Output Ctrl
-
13.5 VDC (26.5 VDC) ± 20%
I Output Ctrl
-
20 ma (MAX)
V Pattern Ctrl
-
13.5 VDC (26.5 VDC) ± 20%
I Pattern Ctrl
-
5 (MAX)
COMET FLASH
®
FLASHRATE (Per Lamp)
-
75 CFPM @ 80 ms
DOUBLE FLASH
FLASHRATE (Per Lamp)
-
120 DFPM @ 80 ms
SINGLE FLASH
FLASHRATE (Per Lamp)
-
220 SFPM
ACTION FLASH
-
3 CYCLES COMET FLASH
-
6 CYCLES SINGLE FLASH
Fig. 1
Switch Operation Table
Pattern Control
Pattern 1&2 Disabled
Comet Flash Pattern
Pattern 1 Enabled
Double Flash Pattern
Pattern 2 Enabled
Single Flash Pattern
Pattern 1&2 Enabled
Action Flash Pattern
Outlet Control
Enable 1A & 4A
Outlets 1A & 4A Active
Enable 2A & 3A
Outlets 2A & 3A Active
Enable 1B & 4B
Outlets 1B & 4B Active
Enable 2B & 3B
Outlets 2B & 3B Active
Fig. 2
NOTE! The WHITE/RED wire in the Pattern
Selection Connector provides positive voltage
designed to be used to supply power to your
switches. This wire is internally protected to 250
ma. If a short circuit occurs, the circuit will inter-
rupt current flow until the short has been
removed.
OUTLETS 1A/1B & 4A/4B = FLASH ALTERNATELY
OUTLETS 2A/2B & 3A/3B = FLASH ALTERNATELY
OUTLETS 1A/1B & 3A/3B = FLASH SIMULTANEOUSLY
OUTLETS 2A/2B & 4A/4B = FLASH SIMULTANEOUSLY
NOTE - The type of switch used is
dependant on how the operator wishes the
Hi/Lo feature to function:
Latching Mode:
By apvoltage to the Violet wire for
less than 1 sec., the power supply is
“latched” into low power operation. The unit
must be turned off and then back on to
restore normal, Hi power operation. A
momentary switch is desired for this style.
Level Mode:
Apvoltage to the Violet wire for
more than 1 sec. holds the power supply in
low power mode until that voltage is
removed. A toggle switch is desired for this
style.
Dimensions shown
for reference only.