Specifications:
12V
Input Voltage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.8 VDC +/- 20%
Input Current / Peak
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 AMP
Input Current / Avg.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6 AMP
Installation:
Installation is left to the installers discretion. Two loop clamps are supplied and
the base has threaded mounting holes (3/8 - 16) and will take customer
supplied bolts. Be sure to secure and dress all wires.
Wiring:
WARNING! All customer supplied wires that connect to the positive
terminal of the battery must be sized to supply at least 125% of the
maximum operating current and FUSED at the battery to carry the load.
DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!
This product is polarity sensitive. If the positive and negative wires are reversed
the unit will not function. Refer to the wiring diagram for connection and fusing.
Operation:
White - Scan-Lock™:
To use ScanLock™, the beacon must be turned on:
To cycle forward to the next available pattern
apply +VBAT to the WHT
wire
for less than 1 second and release.
To cycle back to the previous pattern
apply +VBAT to the WHT
wire for more
than 1 second and release.
To change the default pattern
allow any pattern to run for more than 5 sec-
onds. The beacon will now display this pattern when activated.
Restoring the factory default pattern (CAL
SignalAlert™ SIM):
Turn the
beacon off. Apply +VBAT to the WHT
wire while turning power to the beacon
on. The factory default pattern will now be displayed.
A normally open momentary switch can be used to control Scan-Lock™.
Flash Patterns:
1.
CAL SignalAlert™ - SIM
2.
CAL SignalAlert™ - SIM
3.
CAL SignalAlert™ - ALT
4. CometFlash® 75 - SIM
5. CometFlash® 75 - SIM
6. CometFlash® 75 - ALT
7.
DoubleFlash 75 - SIM
8.
DoubleFlash 75 - SIM
9.
DoubleFlash 75 - ALT
10.
SingleFlash 75 - SIM
11.
SingleFlash 75 - SIM
12.
SingleFlash 75 - ALT
13.ComAlert™ 75 - SIM
14.ComAlert™ 75 - SIM
15.ComAlert™ 75 - ALT
16.LongBurst™ 75 - SIM
17.LongBurst™ 75 - SIM
18.LongBurst™ 75 - ALT
19.
PingPong™ 75 - SIM
20.
PingPong™ 75 - SIM
21.
PingPong™ 75 - ALT
22.
SingleFlash 60 - SIM
23.
SingleFlash 60 - ALT
24.
SingleFlash 90 - SIM
25.
SingleFlash 90 - ALT
26.
SingleFlash 120 - SIM
27.
SingleFlash 120 - ALT
28.SingleFlash 300 - SIM
29.SingleFlash 300 - ALT
30.
DoubleFlash 120 - SIM
31.
DoubleFlash 120 - ALT
32.ComAlert™ 150 - SIM
33.ComAlert™ 150 - ALT
34.
PingPong™ 120 - SIM
35.
PingPong™ 120 - ALT
36.
TripleFlash™ 75 - SIM
37.
TripleFlash™ 75 - ALT
38.
TripleFlash™ 120 - SIM
39.
TripleFlash™ 120 - ALT
40.ActionFlash™ 50 - SIM
41.ActionFlash™ 50 - ALT
42.ActionFlash™ 150 - SIM
43.ActionFlash™ 150 - ALT
44.
ActionFlash™ SF 60/120 - SIM
45.
ActionFlash™ SF 60/120 - ALT
46.
ActionFlash™ SF120/TF75 - SIM
47.
ActionFlash™ SF120/TF75 - SIM
48.
CalScan™ - SIM
49.
CalScan™ - ALT
50.ModuFlash™ - SIM
51.ModuFlash™ - ALT
52.ActionScan™ - SIM
53.ActionScan™ - ALT
54.CAL CometFlash® - SIM
55.CAL CometFlash® - ALT
56.50 RPM
57.75 RPM
58.118 RPM
59.250 RPM
ALT =
Front and Rear Alternate
SIM =
Front and Rear flash simultaneously.
Bold Type =
California Title 13 Compliant
Secure to vehicle using
supplied loop clamps
Adjust pole
height and
lock with
pole clamp
Secure to vehicle using supplied loop clamps
Mounting holes (2) (3/8 - 16 thread)
WIRING DIAGRAM
ALL FUSES AND SWITCHES
ARE CUSTOMER SUPPLIED
BLK - (-) GROUND
RED - (+) POSITIVE
SPST SWITCH
MOMENTARY
SWITCH
(+)
Battery
(-)
WHT/VIO - ScanLock
3 AMP FUSE
1 AMP FUSE
CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.
MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!
I M P O R TA N T W A R N I N G !