Specifications:

12V
Input Voltage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.8 VDC +/- 20%

Input Current / Peak

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1.5 AMP

Input Current / Avg.

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.6 AMP

Installation:

Installation is left to the installers discretion. Two loop clamps are supplied and 
the  base  has  threaded  mounting  holes  (3/8  -  16)  and  will  take  customer 
supplied bolts. Be sure to secure and dress all wires.

Wiring:

WARNING!  All  customer  supplied  wires  that  connect  to  the  positive 
terminal  of  the  battery  must  be  sized  to  supply  at  least  125%  of  the 
maximum operating current and FUSED at the battery to carry the load. 
DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!

This product is polarity sensitive. If the positive and negative wires are reversed 
the unit will not function. Refer to the wiring diagram for connection and fusing. 

Operation:
White - Scan-Lock™:

To use ScanLock™, the beacon must be turned on:

To cycle forward to the next available pattern

 apply +VBAT to the WHT

 

wire 

for less than 1 second and release.

To cycle back to the previous pattern

 apply +VBAT to the WHT

 

wire for more 

than 1 second and release.

To change the default pattern 

allow any pattern to run for more than 5 sec-

onds. The beacon will now display this pattern when activated.

Restoring the factory default pattern (CAL

 

SignalAlert™ SIM):

 

Turn the 

beacon off. Apply +VBAT to the WHT

 

wire while turning power to the beacon 

on. The factory default pattern will now be displayed.

A normally open momentary switch can be used to control Scan-Lock™.

Flash Patterns:

1.

CAL SignalAlert™ - SIM

2.

CAL SignalAlert™ - SIM

3.

CAL SignalAlert™ - ALT

4. CometFlash® 75 - SIM
5. CometFlash® 75 - SIM
6. CometFlash® 75 - ALT
7.

DoubleFlash 75 - SIM

8.

DoubleFlash 75 - SIM

9.

DoubleFlash 75 - ALT

10.

SingleFlash 75 - SIM

11.

SingleFlash 75 - SIM

12.

SingleFlash 75 - ALT

13.ComAlert™ 75 - SIM
14.ComAlert™ 75 - SIM
15.ComAlert™ 75 - ALT

16.LongBurst™ 75 - SIM
17.LongBurst™ 75 - SIM
18.LongBurst™ 75 - ALT
19.

PingPong™ 75 - SIM

20.

PingPong™ 75 - SIM

21.

PingPong™ 75 - ALT

22.

SingleFlash 60 - SIM

23.

SingleFlash 60 - ALT

24.

SingleFlash 90 - SIM

25.

SingleFlash 90 - ALT

26.

SingleFlash 120 - SIM

27.

SingleFlash 120 - ALT

28.SingleFlash 300 - SIM
29.SingleFlash 300 - ALT
30.

DoubleFlash 120 - SIM

31.

DoubleFlash 120 - ALT

32.ComAlert™ 150 - SIM
33.ComAlert™ 150 - ALT
34.

PingPong™ 120 - SIM

35.

PingPong™ 120 - ALT

36.

TripleFlash™ 75 - SIM

37.

TripleFlash™ 75 - ALT

38.

TripleFlash™ 120 - SIM

39.

TripleFlash™ 120 - ALT

40.ActionFlash™ 50 - SIM
41.ActionFlash™ 50 - ALT
42.ActionFlash™ 150 - SIM
43.ActionFlash™ 150 - ALT
44.

ActionFlash™ SF 60/120 - SIM

45.

ActionFlash™ SF 60/120 - ALT

46.

ActionFlash™ SF120/TF75 - SIM

47.

ActionFlash™ SF120/TF75 - SIM

48.

CalScan™ - SIM

49.

CalScan™ - ALT

50.ModuFlash™ - SIM
51.ModuFlash™ - ALT
52.ActionScan™ - SIM
53.ActionScan™ - ALT
54.CAL CometFlash® - SIM
55.CAL CometFlash® - ALT
56.50 RPM
57.75 RPM
58.118 RPM
59.250 RPM

ALT =

 Front and Rear Alternate

SIM =

 Front and Rear flash simultaneously.

Bold Type =

 California Title 13 Compliant

Secure to vehicle using

supplied loop clamps

Adjust pole
height and
lock with
pole clamp

Secure to vehicle using supplied loop clamps

Mounting holes (2) (3/8 - 16 thread)

WIRING DIAGRAM

ALL FUSES AND SWITCHES

ARE CUSTOMER SUPPLIED

BLK - (-) GROUND

RED - (+) POSITIVE

SPST SWITCH

MOMENTARY

SWITCH

(+)

Battery

(-)

WHT/VIO - ScanLock

3 AMP FUSE

1 AMP FUSE

CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

I M P O R TA N T W A R N I N G !