Whelen Engineering Company SCSS85 Скачать руководство пользователя страница 3

Page 3

Not used with

model SCSS85.

Cut wires flush

with cable jacket.

ORG

BLU

1 2

4 5 6

3

7

10

8

11

9

12

12 POSITION

CONNECTOR

(

R

E

AR

VIEW)

SCSS85

RED to

+12V

DC

BLA

C

K

to ground

BL

UE

& G

RE

Y

(

to

MP

C

)

S

C

TA

R

ML6

(

used

wi

th

S

C

SS85)

ORG (POS.1)

RED (POS.1)

BRN (POS. 2)

BLK (POS. 2)

GRN (POS. 3)

WHT (POS. 3)

T

O

P

O

WE

R

SUPPLY

R

IGHT

ST

ROB

E

LIGHTHE

A

D

LEFT

ST

ROB

E

LIGHTHE

A

D

POS 9 =

WHITE

POS 8 =

GREY

POS 7 =

VIOLET

POS 6 =

N/C

POS 5 =

GREEN

POS 3 =

N/C

POS 4 =

YELLOW

POS 2 =

RED

POS 1 =

BROWN

POS 10 =

N/C

POS 11 =

N/C

POS 12 =

N/C

4.

Extend the strobe cable to your strobe power supply. Insert
the  wires  into  their  designated  positions.  Plug  the  strobe
connectors into the desired power supply ports.

After  all  connections  have  been  made,  inspect  the  fuses  at  the
MPC  and  at  the SCTARML6.  If  either  of  these  fuses  are  blown,
carefully  inspect  all  of  the  circuit  wires  and  make  sure  they  are
wired correctly. Replace the blown fuses with one of an identical
amp rating as the original. If these fuses blow after installation or
activation, contact Whelen Engineering Technical Support.

Wiring the Traffic Advisor System:

 

WARNING:

 

All customer supplied wires, that connect to the

positive terminal of the battery, must be sized to supply at least
125% of the maximum operating current, and fused “at the
battery” to carry the load.

1.

Extend the cable from the SCL to the SCTARML6 installed on
your vehicle. 

2.

Following  the  pin  chart  below,  insert  the  contact  wires  into
their  assigned  positions.  A  gentle  pull  on  the  wires  will
confirm they were properly inserted.

3.

Confirm that the remaining SCTARML6 wires are connected
as  shown  below.  Refer  to  your  MPC  manual  for  operating
procedures.

Содержание SCSS85

Страница 1: ...nd or currents Properly protect and use caution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is n...

Страница 2: ...sible measure a distance of 8 from the right hand mounting hole as shown below Mark this area Now measure an additional 1 along the same axis and mark that area 4 As shown below drill a 1 dia cable access hole in the mounting surface at both of these locations 5 Apply a bead of RTV Silicone around the area where the cables exit the backside of the extrusion Make sure that this bead is large enough...

Страница 3: ...PC and at the SCTARML6 If either of these fuses are blown carefully inspect all of the circuit wires and make sure they are wired correctly Replace the blown fuses with one of an identical amp rating as the original If these fuses blow after installation or activation contact Whelen Engineering Technical Support Wiring the Traffic Advisor System WARNING All customer supplied wires that connect to ...

Страница 4: ... 11122002 0 02 0342791 00 68 1963333A07 GROMMET 1 2 GROMMET 5 8 39 0403023 04 14 104286 16JA 11 263424 007 16 1402420 05 13 148120 080 07 742867 001 02 0363043 00 15 061416 060 14 148436 120 38 0263302 00 11 363522 042 13 062C40 16J ENDCAP BLACK GASKET DIVIDER ASSY 9 C CABLE 20 6 LIGHT 3 POS AMP PIN HSG TA ASSY LED L P W STROBES SCSS85 ASS Y CABLE INPUT HARNESS STROBE 12 POS AMP PIN HSG 39 0412014...

Отзывы: