background image

Page 3

Push On Push Off

Timed Output
Flashing Output

Momentary

GRN

Off

On

Off

On

YEL

Off

Off

On

On

Table 2

Slide Switch Indicators

Programming uses the Scan-Lock™ switch located in the rear of the 
unit. This switch is pressed by inserting a pen or other suitable tool 
into the hole indicated (see wiring diagram) to push the momentary 
switch.

(1) Momentary Switch “Switch Type”

Programming:

The six momentary switches can be configured to operate as one of 
four types. The four types are: Push On Push Off, Momentary, 
Flashing Output (60 FPM) and Timed Output (10 seconds).

Factory Default: SW1 - SW5 = push on-push off 

SW6 = Momentary

To Configure a switch’s 

“Switch Type”

:

1. Put the unit into "Switch Type” configuration Mode:

• Place the SLIDE SWITCH in the OFF position and turn all momentary 

switches off.

• Press and hold the Scan-Lock™ switch.
• Press and release momentary switch 1.
• Release the Scan-Lock™ switch.

To confirm entry into this configuration mode: The GREEN slide 
switch indicator light will turn on for 2 seconds.

2. Select a switch to be configured.

• Wait for the GREEN slide switch indicator light to turn off.
• Press and release the momentary switch that you wish to configure.

The selected switch’s indicator light will turn on steady. Slide switch 
indicator lights will display a pattern corresponding to the type of 
switch that has already been configured (table 2).

3. Choose a “Switch Type” for the selected switch.

• Press and release the Scan-Lock™ switch to cycle though the switch 

types (table 2).

• Stop when the indicator lights equal the 

pattern for the desired “switch type”.

4. Store and activate the switch's

“switch type”.

• Move the SLIDE SWITCH to position 1.
• Move the SLIDE SWITCH to the off position.

All of the indicator lights will turn off and the data will be stored. This
will put the unit back into normal operating mode, to configure
another switch start back at step 1.

(2) Momentary Switch, Relay Output

Programming:

Any of the 6 Momentary switches can be configured to activate any 
combination of the nine relay outputs.

Factory Default: See Section 8.1

To Configure a momentary switch's relay outputs:

1.

 

Put the unit into "Momentary Switch Relay Output"

configuration mode.

• Place the SLIDE SWITCH in the OFF position and turn all

Momentary switches off.

• Press and hold the Scan-Lock™ switch.
• Press and release momentary switch 2.
• Release the Scan-Lock™ switch.

To confirm entry into this configuration mode: The Yellow slide 
switch indicator light will turn on for 2 seconds.

2.

 

Select a switch to be configured.

• Wait for the 

YELLOW slide switch indicator light t

o turn off.

• Press and release the momentary switch that you wish to configure.

All switch indicator lights whose corresponding relay output is 
already in the selected switch's configuration will turn on steady.

3. Add or delete relay outputs activated by the switch:

• Press and release one of the six momentary switches to add or delete 

its corresponding output. This switches indicator light will turn on steady 
when its corresponding output is selected to be activated.

OR... 

• Press and release the Scan-Lock™ switch to cycle though the SLIDE 

SWITCH’S corresponding outputs. Stop when indicator lights equal the 
desired output pattern.

4. Store and activate the switch's relay output pattern.

• Move the SLIDE SWITCH to position 1.
• Move the SLIDE SWITCH to the off position.

All of the indicator lights will turn off and the data will be stored.  
This will put the unit back into normal operating mode, to configure 
another switch start back at step 1.

(3) Slide Switch, Relay Output Programming:

Any of the 3 active Slide Switch positions can be configured to 
activate any combination of nine relay outputs.

Factory Default: See Section 8.1

To configure a slide switch position’s relay outputs:

1. Select a switch position to be configured and put the unit

into "Slide Switch Relay Output" configuration mode.

• Turn all Momentary switches off.
• Place the SLIDE SWITCH in the position that you wish to configure.
• Press and release the Scan-Lock™ switch.

All switch indicator lights whose corresponding relay output is 
already in the selected Slide Switch position’s configuration will turn 
on steady.

2.

 

Add or delete relay outputs activated by the selected

switch:

• Press and release one of the six momentary switches to add or delete 

its corresponding output. This switches indicator light will turn on steady 
when its corresponding output is selected to be activated.

OR... 

• Press and release the Scan-Lock™ switch to cycle through the SLIDE 

SWITCH’S corresponding outputs. Stop when the indicator lights equal 
the desired output pattern.

3.

 

Store and activate the switch's relay output pattern.

• Move the SLIDE SWITCH to the off position.

All of the indicator lights will turn off and the data will be stored.
This will put the unit back into normal operating mode, to configure
another slide switch position start back at step 1.

Содержание PCCS9RW

Страница 1: ...aution around live electrical connections Grounding or shorting of electrical connections can cause high current arcing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment...

Страница 2: ... manufacturer s instructions for mounting information If a console type mount is not possible the PCCS9RW includes a bail strap mounting kit for over or under dash mounting WARNING Regardless of the style selected be sure to observe the air bag warning on the cover of this manual WARNING Mounting this unit will require drilling It is absolutely necessary to make sure that no other vehicle componen...

Страница 3: ...se the Scan Lock switch To confirm entry into this configuration mode The Yellow slide switch indicator light will turn on for 2 seconds 2 Select a switch to be configured Wait for the YELLOW slide switch indicator light to turn off Press and release the momentary switch that you wish to configure All switch indicator lights whose corresponding relay output is already in the selected switch s conf...

Страница 4: ... switches Factory Default No momentary switches are remotely activated To activate Momentary Switches 1 Put the unit into Momentary Switch Activation Mode Place the SLIDE SWITCH in the OFF position and turn all momentary switches off Press and hold the Scan Lock switch Press and release momentary switch 5 Release the Scan Lock switch To confirm entry into this configuration mode The YELLOW and RED...

Страница 5: ...ff on both the primary and secondary units To transfer the configuration to another unit start back at step 1 8 Terminal Operation 8 1 Terminal Specifications This PCCS9RW contains 11 outlets Faston connectors located on the rear panel They are designed to activate components that do not exceed specific current draw NOTE It is important that any components connected to these terminals do not excee...

Отзывы: