SWITCH 9 CAN TO OPERATE IN 4 DIFFERENT MODES,
DEFINED BY THE 4 POSITION DIP SWITCH

:

-

(Bank 4)

PANEL SWITCH 9

OPERATING MODE:

MOMENTARY

1 2 3 4

MODE 1 (DEFAULT)

PANEL SWITCH 9

OPERATING MODE:

8 SECOND ON TIMER

off off

on

1 2 3 4

MODE 2

PANEL SWITCH 9

OPERATING MODE:

LATCH ON

LATCH OFF

off off

on

on

on

on

on

1 2 3 4

MODE 3

PANEL SWITCH 9

OPERATING MODE:

FLASHER

(400MS ON & OFF)

off

off

on

1 2 3 4

MODE 4

ON

OFF

Down

(OFF)

Down

(OFF)

Down

(OFF)

Down

(ON)

DIP SWITCH CHART / 4-POSITION / BANK 4

Default (factory) setting shown.

Switch 9

(momentary)

1

ON

OFF

2

3

4

Custom Dip Switch Configuration (Dip Switch Bank 4):

Push-button 9 (momentary switch) can function in 4 different modes, defined by the 4-position dip switch bank 4. This bank is located on
top of the circuit board and is only accessible with the cover removed from the PCCS9NP.

Mode 1 -

 (default) - In this configuration, the output is activated for as

long as push-button 9 is depressed.

Mode  2  -

  In  this  configuration,  when  push-button  9  is  pressed,  the

output is activated for a period of 8 seconds.

Mode  3  -

  In  this  configuration,  when  push-button  9  is  pressed,  the

output is activated. When pressed again, the output is deactivated.

Mode  4  -

  In  this  configuration,  when  push-button  9  is  pressed,  the

output is activated for a period of 400 ms. After 400 ms, the output is
deactivated for 400 ms. This cycle will continue until push-button 9 is
pressed again.

Note

  -  Dip  Switch  1  is  used  to  enable/disable  the Aux  Siren

(WHT/GRN)  wire.  In  the  default  position  (ON),  this  wire  is
enabled. Moving Dip Switch 1 to the OFF position will disable
this wire. This switch should be left in the default position. If this
wire is not used, move Dip Switch 1 to the OFF position.

Dip Switch

Bank 1

Dip Switch

Bank 4

Dip Switch

Bank 2

Dip Switch

Bank 3

9-Pin Connector (Output Control
Wires): 

Using  the  information  shown  in  the
illustration  on  page 3,  connect  the
appropriate output wire to the desired input
control wire.

Configuring Slide Switch Control: 

The slide switch has four positions: 0 (off),
1, 2 & 3. When in position 0 (furthest to the
left) the slide switch has not activated any
outputs.  In  position  1,  2  or  3  the  slide
switch  can  activate  any  combination  of
outputs  1  through  8.  Each  active  slide
switch position uses a bank of dip switches
to determine which outputs are to be active
while  the  slide  switch  is  in  that  position;
position 1 uses dip switch bank 1, position
2  uses  dip  switch  bank  2  and  position  3
uses dip switch bank 3.

Each  dip  switch  bank  is  comprised  of  8
switches, 

each 

representing 

a

corresponding  output  (switch  1  for  output
1,  switch  2  for  output  2,  etc.).  If,  for
example, switches 1, 3, 4 & 6 on dip switch
bank 1 are in the ON position, outputs 1, 3,
4 & 6 will be active when the slide switch is
moved to position 1.

Slide  switch  configuration  is  as  simple  as
deciding which outputs are to be active in a
given  position  and  then  moving  the
corresponding 

dip 

switch 

on 

the

appropriate  dip  switch  bank  to  the  ON
position.

1 - Slide Switch Output 1 (GRN)
2 - Slide Switch Output 2 (GRY)
3 - Slide Switch Output 3 (BLU)
4 - Switch 4 Output (WHT/BLK)
5 - Switch 5 Output (WHT)
6 - Switch 6 Output (YEL)
7 - Switch 7 Output (ORN)
8 - Switch 8 Output (BLK/WHT)

8

7

6

5

4

3

2

1

Dip Switch

Bank 1

Dip Switch

Bank 2

Dip Switch

Bank 3

8

7

6

5

4

3

2

1

8

7

6

5

4

3

2

1

8

7

6

5

4

3

2

1

= OFF

= ON