Electrical Specifications

.35 Amps

Peak:

.75 amps

Peak:

SignalAlert™ / Sim.

Input Current

Input Voltage

Power

12.8 VDC ± 20%

12V

25.6 VDC ± 20%

24V

Avg:

.14 amps

.3 amps

Avg:

Default Flash Pattern

SignalAlert™ / Sim.

S P S T

switch

Momentary switch

3 AMP

F u s e

Connect to SYNC wire of

other beacon or Cut & cap

GREY wire

RED

BLK

WHT/VIO

GREY

BATTERY

PERMANENT
MOUNT

"J" HOOK
MOUNT

Fig. 1

The L22 Beacon

 has fully encapsulated electronics that are impervious to

damage from moisture and vibration. Some beacons feature an automatic
photocell High Power override. This beacon also features Scan-Lock™ to
choose  between  25  available  flash  patterns.  6  mounting  options  are
available: mirror mount (Optional), permanent mount, pipe mount, J-hook
mount,  magnetic  mount  and  Vacuum  mount.  (Magnetic  and  Vacuum
mount models do not include SYNC) All models are SAE certified.

IMPORTANT! All beacons in this manual should be fused at 3 AMPS.

IMPORTANT! Always be sure the drain hole (located on the bottom of
the base) is facing the rear of the vehicle after mounting.

WARNING: All customer supplied wires that connect to the positive
terminal of the battery must be sized to supply at least 125% of the
maximum  operating  current  and  FUSED  at  the  battery  to  carry  the
load. DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!

Wiring:

Listed below are the wire designations for the L22 beacon. To extend the
beacons wires, use the wire gauge indicated.

WIRE COLOR . . . . . . . . . .  WIRE GAUGE  . . . . . . . . . . . . . . .FUNCTION
RED

. . . . . . . . . . . . . . . . . .  18 AWG

 . . . . . . . . . . . . . . . . . . . . . . .Positive

BLACK

 . . . . . . . . . . . . . . .  18 AWG

 . . . . . . . . . . . . . . . . . . . . . . . Ground

GREY

 . . . . . . . . . . . . . . . .  18 or 22 AWG

. . . . . . . . . . . . . . . . . . . . SYNC

WHITE-VIOLET

. . . . . . . . .  18 or 22 AWG

. . . . . . . . . . . . . . .Scan-Lock™

Mounting:

“J” Hook Mount:

This beacon is equipped to handle the “J” hook mount 

available on some

beacons

. Be sure to use the correct “J” hook mounting holes (Fig. 1). 

PERMANENT MOUNT:

1.

Use the base as a template and mark the three mounting holes off
onto the mounting surface. Remove base. In the center between the
three mounting holes, mark the location of the wire access hole.

2.

Drill the mounting holes with a #16 drill bit. Drill the wire access hole
using a 3/8” drill bit. Remove any burrs from the wire access hole and
It is also recommended that you install a rubber grommet 

(customer

supplied)

 into the wire hole to protect the wires.

3.

A base seal is used between the beacon base and mounting surface.

4.

Feed the wires first through the base seal and then through the cable
access hole and place the base 

(with seal)

 on the mounting surface

(while lining up the mounting holes in the base with the mounting
holes you drilled into the mounting surface).

  Secure  the  beacon

firmly to the mounting surface with the supplied mounting screws.

1 Inch (NPT) Pipe Mount:

Threading  for  a  1  inch 

(NPT)

  pipe  mounting  is  precast  in  the  base

(pipe not included with beacon).

1.

Feed power cable through the 1 inch pipe and connect the cable to
the wires of the beacon.

2.

Screw the beacon into the threads on the 1” pipe, taking precaution
not to damage the connected power wires. Do not tighten base too
hard as not to damage threads on base.

Temporary Mounting (Optional):

IMPORTANT  WARNING:  The  use  of  any  magnetically  mounted
warning  device  on  the  outside  of  a  vehicle  in  motion  is  not
recommended and is at the sole risk and responsibility of the user.

Magnetic/suction:

 Thoroughly clean the proposed mounting surface prior

to mounting. For suction cup mounting, wipe the suction cup clean, place
the beacon onto its mounting surface and apply gentle pressure to ensure
a good seal has been achieved. Magnetic/Suction Cups mount the same
as  standard  suction  cups  but  are
best suited to a flat, steel surface.

Magnetic:

 Place the beacon onto

the  mounting  surface  and  plug  it
into  the  vehicle  cigar  lighter.
Magnetic  mount  models  do  not
offer SYNC.

Operation: SYNC:

 

To  SYNC  two  beacons,  configure  both  beacons  to  display  the  same
Phase  1  (Simultaneous)  pattern.  Turn  the  power  off  and  connect  the
GREY wire from each beacon together. When the beacons are activated
their patterns will be synchronized. To configure two beacons to alternate
their  patterns,  advance  the  pattern  of  either  beacon  to  Phase  2
(Alternating) of the current pattern. (Not available on cigar plug models)

Hi/Lo Power: Photocell

 

If  this  beacon  is  equipped  with  photocell  Hi-Lo,  the  beacon  will
automatically step down to low power at night. This feature is optional.

Programming / Scan-Lock™ / White-Violet:

To  cycle  forward  through  all  patterns: 

With  the  beacon  switched  on,

apply Positive (+) voltage to the WHT-VIO wire for less than 1 second and
release. 

To  cycle  backward

 

through  all  patterns:

  Apply  Positive  (+)

voltage to the WHT-VIO wire for more than 1 second and release.

To set a pattern as default: 

When the desired pattern is displayed, allow

it to run for more than 5 seconds. The beacon will now display this pattern
when activated.

To  reset  to  the  factory  default  pattern: 

Turn  off  power.  Now,  while

applying Positive (+) voltage to the WHITE-VIOLET wire, turn power on.

NOTE: Cigar cord models have a momentary switch on the plug to
control Scan-Lock™ as well as an On-Off switch.

NOTE: The cigar cord adaptor
is equipped with an 8 Amp fuse.
Use a replacement fuse with an
identical value.

Switch Functions:

SW1 = ON/OFF
SW2 = Scan-Lock™ / Momentary

(12 volt model only)

CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

I M P O R TA N T W A R N I N G !

Содержание L22H Series

Страница 1: ...ch can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment simultaneously to insure that they operate free of interference from other components within the vehicle Never power emerg...

Страница 2: ...ace with the supplied mounting screws 1 Inch NPT Pipe Mount Threading for a 1 inch NPT pipe mounting is precast in the base pipe not included with beacon 1 Feed power cable through the 1 inch pipe and connect the cable to the wires of the beacon 2 Screw the beacon into the threads on the 1 pipe taking precaution not to damage the connected power wires Do not tighten base too hard as not to damage ...

Страница 3: ...1 1 A R A R 1 1 1 1 2 2 1 1 2 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 L22E LED BEACON 12V PLASTIC VAC MT PHOTOCELL L22E LED BEACON 12V PLASTIC VAC MT L22E LED BEACON 12V PLASTIC MAG MT L22E LED BEACON 12V PLASTIC MAG MT PHOTOCELL O RING 4 724 ID X 079 THK 70 DUROMETER BLK SUB ASSY BALLAST L22E 12V PLAS CIG PLUG PHOTO LENS OPTIC MODEL 1079 RED HI LENS OPTIC MODEL 1079 GREEN HI LENS OPTIC MODEL 1079...

Страница 4: ...3 14 15 16 17 4 5 6 7 8 9 10 1 68 2180452 50 68 2180452 40 68 2180452 30 68 2180452 20 01 06863463_2 01 06863464_2 01 06863463_3 01 06863464_3 01 02863452_3 01 02863452_4 01 02863453_3 01 02863453_4 01 02863453_2 01 02863453_1 01 06863462_3 01 0686346 _3 15 065419 080 01 02863452_2 01 02863452_1 01 06863462_2 01 0686346 _2 38 0241596 00 15 101416 100 13 062C40 16J 38 0443007 00 68 2180452 10 A R A...

Отзывы: