background image

Page 4

10 AMP FUSE

SPST SWITCH / 15 AMP

12 VDC BATTERY

RED

BLACK

1

-RED

2

-BLACK

3

-VIOLET

4

-WHITE

Pattern Selection

MOMENTARY

SWITCH

(For Programming)

WHITE

Low Power Control

SPST SWITCH

Option

2

MOMENTARY

SWITCH

Option

1

3 AMP FUSE

+12

VDC

OR

Fig. 4 Flash Patterns & Hi/Low

(Permanent Mount only)

VIOLET

Specifications: Guardian™ Power Supply

Input Voltage

 . . . . . . . . . . . . . . . . . . . . . 12.8 / 25.6 VDC ±20

Input Current

 . . . . . . . . . . . . . . . . . . . . . 3 AMP/ 1.6 AMP

Flash Rate

 . . . . . . . . . . . . . . . . . . . . . . . 120 CFPM

Fill Flash

. . . . . . . . . . . . . . . . . . . . . . . . . 100ms

Energy

 . . . . . . . . . . . . . . . . . . . . . . . . . . HI  1.9/1.9/1.9/6 JOULES

LO  1.9/1.9/1.9/1.9 JOULES

Default Pattern

. . . . . . . . . . . . . . . . . . . . CometFlash®

The Guardian™ Power Supply:

If  your  lightbar  comes  equipped  with  the  Guardian™  strobe  power
supply,  you  will  have  a  choice  of  10  changeable  flash  patterns. This
power supply also comes with a Hi/Low feature to switch the beacons
from  high  to  low  power. 

These  features  are  only  available  on

permanent mount models.

Wiring:

WARNING! The  strobe  light  power  supply  is  a  high  voltage
device. Do not touch or remove tube assembly in strobe light
head  assemblies  while  in  operation.  Wait  10  minutes  after
disconnecting the unit from its power source before starting
work or troubleshooting on power supply or system.

WARNING!  All  customer  supplied  wires  that  connect  to  the
positive  terminal  of  the  battery  must  be  sized  to  supply  at
least 125% of the maximum operating current and FUSED at
the  battery  to  carry  that  load.  DO  NOT  USE  CIRCUIT
BREAKERS WITH THIS PRODUCT!

Note: All fuses and fuse blocks are customer supplied

1.

Extend  the  4  wires  exiting  the  lightbar  to  the  designations
shown in figure 4.

2.

Connect the RED wire to a fuse block (customer supplied) and
then to the POSITIVE terminal on the battery. Do not install the
fuse until 

ALL

 of the wire connections are completed. Refer to

the wiring diagram for the appropriate fuse value needed.

3.

Connect  the  black  wire  to  the  factory  chassis  ground  typically
adjacent to the battery.

Low Power Control / Violet:

The type of switch used depends on how the operator wishes the Hi/
Low feature to function:

Latching  Mode: 

By  applying  +voltage  to  the  VIOLET  power  supply

wire for less than 1 sec., the power supply is “latched” into low power
operation.  The  unit  must  be  turned  off  and  then  back  on  to  restore
normal, Hi power operation. A momentary switch is desired for this.

Level Mode:

 Apvoltage to the VIOLET power supply wire for

more than 1 sec. holds the power supply in low power mode until that
voltage is removed. A toggle switch is desired for this.

Pattern Selection / White:

This is a positive activation input. A momentary activation (less than 1
second) of the WHITE wire will change the default flash pattern to the
next  available  pattern.  If  the  new  pattern  is  active  for  more  than  1
second, it will become the new default pattern. A momentary activation
(more  than  1  second)  will  cause  the  power  supply  to  change  the
default flash pattern to the previous available pattern. If the input is tied
to positive while the unit is powered up, the default pattern will change
to CometFlash®.

Available Flash Patterns:

1 -

 

CometFlash® 120

 . . . . . . . . . . . . . . 120 CFPM @ 200 mS/100mS

2 -

 

TripleFlash™ 150

. . . . . . . . . . . . . . . . 150 FPM @ 200 mS/100mS

3 -

 

DoubleFlash 180

 . . . . . . . . . . . . . . . . 180 FPM @ 230 mS/100mS

4 -

 

Single Flash 400

 . . . . . . . . . . . . . . . . . . . . . .  400 FPM @ 150 mS

5 -

 

ActionFlash™

 . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Comet 4 Singles

6 -

 

ModuFlash™

 . . . . . . . . . . . . . . . . . .175 FPM @ 384mS to 150mS

7 -

 

MicroBurst II™

. . . . . . . . . . . . . . . . . . .200 FPM @ 200mS/100mS

8 -

 

MicroBurst III™

 . . . . . . . . . . . . . . . . . .190 FPM @ 200mS/100mS

9 -

 

LongBurst™

. . . . . . . . . . . . . . . . . . . . . . . . . .  140 FPM @ 100 mS

10 -

 

ActionScan™

. . . . . . . . . . . . . . . . . . . . . . . All Patterns / Random

Содержание Guardian G7M Series

Страница 1: ...cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment simultaneously to insure that they operate free of interference from other components within the vehicle Never power emergency wa...

Страница 2: ...unting surface 2 Mark off the wire access hole located right behind the lightbar 3 Drill the mounting holes you marked off in step 1 with a 3 16 drill bit and the wire access hole with a 3 8 drill bit 4 Install a 3 8 rubber grommet in the wire access hole and route the wires through then apply a silicone sealing compound around the wires and grommet 5 Carefully position the lightbar over the mount...

Страница 3: ...base interferes with the screwdrivers access to the lens screw you may have to remove the 3 mounting screws holding the beacon to the base and lift the beacon 2 Remove the beacons lens screws and remove the lens If your beacon is equipped with diamond mirrors to gain access to the beacon lens screws you may have to first remove the mirrors 3 Install the new flash tube making sure to align the 3 pr...

Страница 4: ...ied and then to the POSITIVE terminal on the battery Do not install the fuse until ALL of the wire connections are completed Refer to the wiring diagram for the appropriate fuse value needed 3 Connect the black wire to the factory chassis ground typically adjacent to the battery Low Power Control Violet The type of switch used depends on how the operator wishes the Hi Low feature to function Latch...

Отзывы: