Page 2

Fuse each @

5A (12V) or 3A (24V)

1A

Fuse

= Switch, SP/ST
= Switch, Momentary

(Normally Open)

WHT/VIO

BLK

RED

WHT/ORG

R416E

ScanLock

Ground

Power

Cruise

GRY

SYNC

See Text

Note: Fuses and switches

are customer supplied.

Wiring Diagram

(+)

Battery

(-)

Low Power *

VIO

*

= Low Power not available in

Amber models (see text).

or

Bottom

 

v

i

ew

 

o

Base

A

D

A

P

T

E

R

P

L

A

T

E

8 X 

5

/8 

Ph

illi

ps

F

l

at

 

Head

 

Screw

6-

32

 X 

3

/

4

PPHMS

3

/8" 

Cab

l

e

Access

 

Ho

l

e

Wiring:

WARNING! All customer supplied wires that connect to the positive terminal of
the battery must be sized to supply at least 125% of the maximum operating
current  and  FUSED  at  the  battery  to  carry  that  load.  DO  NOT  USE  CIRCUIT
BREAKERS WITH THIS PRODUCT!

Operation: 

Low Power: (Low power not available in Amber models)
Latching Mode:

 By apVBAT to the VIOLET wire for less than 1 second, the

light  is  “latched”  into  low  power. The  unit  must  be  turned  off  and  then  back  on  to
restore normal high power operation (Momentary switch).

Level Mode:

 ApVBAT to the VIOLET wire for more than 1 second holds the

lightbar in low power mode until voltage is removed (Toggle switch).

Scan-Lock™

  -  Activate  the  power  wire  to  turn  on  the  beacon. 

To cycle forward

through patterns

, activate the WHT/VIO wire for less than 1 second and release. 

To

cycle backward through patterns

, activate the WHT/VIO wire for more than 1 second

and  release. 

To choose a pattern

,  allow  it  to  run  for  more  than  5  seconds.  The

beacon  will  now  display  this  pattern  when  active.  To  reset  to  the  factory  default
pattern, turn off power, activate the WHT/VIO wire, then turn power back on. Use a
normally open momentary switch to control Scan-lock™.

Flash Patterns:

1.

Rotator 125 PH1 (Clockwise)

2.

Rotator 125 PH2 (Clockwise)

3.

Rotator 125 PH1 (Counter-Clockwise)

4.

Rotator 125 PH2 (Counter-Clockwise)

5.

thru 29 (contact your local distributor)

IMPORTANT! It is the responsibility of the installation technician to make sure
that the installation and operation of this product:

A)  will  not  interfere  with,  or  compromise  the  operation  or  efficiency  of  any
vehicle equipment.

B)  conforms  to  any  and  all  applicable  UNECE  regulations  prior  to  field
operation.

SYNC - All beacons configured to display the Phase 1 mode of a pattern will flash
simultaneously. Any beacons configured to display the Phase 2 mode of a pattern,
will alternate with any Phase 1 beacons of the same pattern.

To SYNC two beacons, configure both beacons to display the same Phase 1 pattern.
With  the  power  off,  connect  the  GRY  wire  from  each  beacon  together.  When  the
beacons are activated, their patterns will be synchronized. If you want the beacons to
alternate their patterns, advance the pattern of either beacon to the Phase 2 mode of
the current pattern.

Do not SYNC more than 8 beacons.

This beacon must be mounted in a normal, ‘dome-up’ position. 

Permanent Surface Mount:

Adapter Plate

1. Place the adapter plate onto the proposed mounting location. Using the plate as a

template, mark the three mounting hole locations onto the mounting surface. Mark
the  location  for  the  wire  passage  hole.  Note  that  this  hole  must  be  centered
between the three mounting holes (Fig. 1).

2. Using  a  drill  bit  sized  for  #6-32  Phillips  pan  head  machine  screws,  drill  the  3

mounting holes. Using a 3/8 bit, drill the cable access hole. Deburr all 4 holes and
install a rubber grommet 

(user supplied) 

in the wire passage hole.

3. Secure  the  adapter  plate  to  the  beacon  base  using  the  3,  #8  x  5/8  Phillips  flat

head screws provided.

4. The next step will require access to the underside of the mounting surface and an

assistant. Position the base seal onto the mounting surface so that all the holes
are  aligned.  Route  the  beacon  wires  down  through  the  wire  passage  hole  and
place the beacon onto the mounting surface.

5. Insert  the  3,  #6-32  x  3/4  Phillips  pan  head  machine  screws  up  through  the

mounting  surface  and  into  the  threaded  holes  in  the  adapter  plate. Tighten  the
screws firmly to secure the beacon.

Direct Mount

1. Using  the  beacon  base  as  a  template,  mark  the  three  mounting  hole  locations

onto the mounting surface. Mark the location for the wire passage hole. Note that
this hole must be centered between the three mounting holes.

2. Drill  the  mounting  holes  into  the  mounting

surface  with  a  #16  drill  bit.  Drill  the  wire
passage  hole  with  a  3/8”  drill  bit.  Deburr  the
wire passage hole and install a rubber grommet

(user supplied)

 into the wire passage hole.

3. Position  the  base  seal  onto  the  mounting

surface so that all the holes are aligned. Route
the  beacon  wires  down  through  the  wire
passage  hole  and  place  the  beacon  onto  the
mounting surface.

4. Secure  the  beacon  firmly  to  the  mounting

surface  using  the  supplied  #10  mounting
screws.

Note:  This  beacon  may  be  mounted  using  “J”  hooks.  Be  sure  to  use  the
correct “J” hook mounting holes as shown.

Temporary Mount (Optional)

WARNING:  The  use  of  any  magnetically  mounted  warning  device  on  the

outside of a vehicle in motion is not recommended and is at the sole risk and

responsibility of the user.
Note: Models with magnetic mounting styles do not offer Low Power or SYNC
Magnetic/Suction:

  Thoroughly  clean  the  proposed  mounting  surface  prior  to

mounting. Wipe the suction cup clean, place the beacon onto its mounting surface
and  apply  gentle  pressure  to  ensure  a  good  seal  has  been  achieved  and  that  the
magnet  is  in  full  contact  with  the  mounting  surface.  Magnetic/Suction  mounting  is
best suited to a flat, steel surface.

Magnetic (Single and Triple Magnet):

 Place the beacon onto the mounting surface

and plug it into the vehicle cigar lighter.

BASE
SEAL

8 X 

5

/8 

PFH

SS

 

SCREW

 

(

QT

Y 2)

6-

32

 X 

3

/

4

PPHMS

(

QT

Y 3)

ADAP

T

ER

PLA

T

E

Fig. 1

BOLD = UNECE Compliant

Italic = SYNC Pattern

PH1 = Phase 1
PH2 = Phase 2

CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

I M P O R TA N T W A R N I N G !

PERM
MO

U

N

T

"J"

HOOK

MO

U

N

T

Cigar Cord Operation

M

6

x10mm Bolt

Bracket

PPH Screw, #

8

x1/2

Triple Magnet Mount

Magnet/Suction Mount

Washer, Rubber

Flat Washer

1/4-20 x 3/4 PPHMS

8

 x ½ PPHSMS

Adaptor Plate

Suction Cup

Magnet

NOTE: The cigar cord adaptor
is equipped with an

8

Amp

f

use.

Replacement 

f

uses must have an

identical value.

Switch Functions:

SW1 = ON/OFF
SW2 = Scan-Lock™ / Momentary