Page 2
DRIVER SIDE
EXAMPLE:
Two, 2-light Dominators™ mounted on the rear deck.
Phase 1 / ALT
Phase 2 / ALT
Phase 1 / SIM
Phase 2 / SIM
PASSENGER SIDE
Phase 1 / ALT
Phase 1 / SIM
Phase 1 / SIM
Phase 1 / ALT
GRY (SYNC)
WHT/VIO (Scan-Lock)
BLK (Ground)
BLK (Ground)
RED (+12VDC/Fuse @ 5A)
RED (+12VDC/Fuse @ 5A)
WHT/VIO (Scan-Lock)
GRY (SYNC)
Butt Splice
Specifications:
Input Voltage:
12.8 VDC +/- 20%
Input Current - Sim:
Peak - 3.2 Amps (Avg.: 1.28 Amps)
Input Current - Alt:
Peak - 1.6 Amps (Avg.: 0.64 Amps)
Input Sync:
Active Low
Sync Phase:
Phase I & II @ 400ms
Input Scan-Lock™:
+12 VDC @ 20 ma
Installation:
IMPORTANT! The lightbar should be located a minimum of
16" from any radio antennas!
Note: When
routing the wires,
it
is
very
important
that
you choose a
path
that
will
keep the wires
away
from
excessive heat or
any
vehicle
equipment
that
could
compromise the integrity of the wires (ex. trunk lids, door jams,
etc.).
1.
Position the unit in its proposed mounting location. Draw a pencil
line onto the mounting surface along the top and bottom of the
extrusion and a “centerline” centered between the two.
2.
Two 1/4” holes are required to mount this unit. These holes may
be located anywhere along the horizontal centerline that you drew
in step one. It’s best to locate the holes as far apart as possible.
Mark the hole location onto the mounting surface.
3.
Using a 1/4” drill bit, drill a hole in each of the areas scribed in the
previous step.
4.
Slide the 2 carriage bolts (installed in the rear of the bar) over to
the 2 mounting holes, install the rubber gaskets onto the bolts then
insert them into the mounting holes.
5.
Secure the unit by threading the flat washer and elastic stop nut
onto each bolt and tightening them firmly.
Wiring:
Refer to the wiring diagram on the next page.
WARNING: All customer supplied wires that connect to the posi-
tive terminal of the battery must be sized to supply at least 125%
of the maximum operating current and FUSED at the battery to
carry that load. DO NOT USE CIRCUIT BREAKERS WITH THIS
PRODUCT!
Operation: White/Violet / Scan-Lock™
Scan-Lock allows you to choose from several flash patterns. To
change a flash pattern, turn on the desired lighthead:
CYCLE THROUGH ALL PATTERNS: To cycle forward,
apply +12
volts to the WHITE/VIOLET wire for less than 1 second and release.
To
cycle backward,
apply +12 volts to the WHITE/VIOLET wire for more
than 1 second and release.
SET A PATTERN AS DEFAULT:
When the desired pattern is displayed,
allow it to run for more than 5 seconds. The lighthead will now display this
pattern when active.
RESET TO THE FACTORY DEFAULT PATTERN:
Turn off power and apply
+12 volts to the WHITE/VIOLET wire while turning power back on.
Note: If you wish to connect the pattern selection wire (WHITE/ VIOLET)
to a switch, an SPST momentary switch is recommended.
Available Scan-Lock™ Flash Patterns:
4, 6 & 8 Lamp Arrays:
SignalAlert™ 75 > CometFlash® 75 > SingleFlash
375 > SingleFlash 75 > ActionFlash™ > ModuFlash™ > ZigZag 60 > ZigZag
90 ZigZag 120 > ActionScan™
2 Lamp Array:
Signal Alert™ 75 > CometFlash® 75 > SingleFlash 375
SingleFlash 75 > ActionFlash™ > ModuFlash™ > ActionScan™
Grey / SYNC:
As an example, we will synchronize two 2 lighthead Dominators™. The 2-
lighthead Dominator™ has 4 unique modes for each of the 4 flash
patterns that can be synchronized; Alternating Phase 1, Alternating Phase 2,
Simultaneous Phase 1 and Simultaneous Phase 2.
In Alternating Mode:
The left lightbar alternates with the right lightbar.
In Simultaneous Mode:
The left and right lightbars flash simultaneously.
End view of extrusion with endcap removed.
MOUNTING
SURFACE
#10 .631 DIA. X .060
FLAT WASHER
#10-24
ELASTIC
STOP NUT
DISK GASKET
BASE
EXTRUSION
Synchronized lightbars, must be set to the same pattern. Not all
patterns can be synchronized. Below are patterns available for SYNC.
Available Sync Patterns
Pattern Sequence
4, 6 & 8 Lamp Arrays
SignalAlert™ 75 ................. Alt. - In-Out - Checker Board - Sim. Phase I - Sim. Phase II
CometFlash® 75 ............... Alt. - In-Out - Checker Board - Sim. - Phase I - Sim. Phase II
SingleFlash 375 ................ Alt. - In-Out - Checker Board - Sim. - Phase I - Sim. Phase II
SingleFlash 75 .................. Alt. - In-Out - Checker Board - Sim. - Phase I - Sim. Phase II
2 Lamp Array:
SignalAlert™ 75 .............. Alternating - Simultaneous - Phase I - Simultaneous Phase II
CometFlash® 75 .............. Alternating - Simultaneous - Phase I - Simultaneous Phase II
SingleFlash 375 ............... Alternating - Simultaneous - Phase I - Simultaneous Phase II
SingleFlash 75 ................. Alternating - Simultaneous - Phase I - Simultaneous Phase II
Wiring