1. Remove four cover screws and remove the cover.
2. Mount the unit to the mounting surface using four
appropriate screws (not supplied). Set the speaker
angle, left or right, by loosening the internal Locknut,
rotating the speaker and locking the Locknut.
3. Route the AC wiring through righthand 3/4” NPT
hole, in the bottom of the unit. Route the control and
paging wires through the lefthand 3/4” NPT hole.
(Cable clamps are not supplied).
4. Use wire nuts to connect the AC service. The
BLACK wire is Hot, the WHITE wire is Neutral.
Connect the service ground to the large brass screw
near the knockouts.
5. Connect a Normally Open contact closure between
the desired tone and one of the RTN terminals. If all
four tones are in use, more than one wire may be
installed in each RTN terminal. Connecting the
same closure to more than one COYOTE
may
introduce an undesirable ground loop condition.
Separate switch closures or poles are recommended.
6. Select the tone by setting the rotary switch that
corresponds to the Input Terminals. For example, the
leftmost Tone Selection Switch (marked Input 1 on
the drawing below) corresponds to the leftmost Input
Terminal (marked 1 below.). The tones are described
in the Table. Note that the tone selection number may
vary from switch to switch.
7. Set the Input 1 Timing Jumper. If the jumper is
installed, Tone 1 will time out after 3 minutes, with
jumper 1 removed, Tone 1 will follow the contact
closure at Input Terminal 1. Tones 2, 3 and 4 always
follow their respective closures.
8. Most tones (see Table) include a 10 second Ramp
Up period, to full output power. The Ramp Up
Jumper enables or disables this feature for all tones.
CAUTION:
HEARING PROTECTION IS RECOMMENDED
DURING STEPS 9, 10 AND 11.
9. Set the Output Volume to a low setting. Apply
power. Set the Output Volume by adjusting the
potentiometer. There may be a loud “pop” on power
up.
10. Connect the Paging Input if used. Set the Paging
Volume by adjusting the potentiometer. This setting
should be made after the Output Volume is set.
11. Install the cover and test the set up.
MOUNTING HOLES, 4 CORNERS
.56" SHOULDER DIA. OPENING
.29" THREAD DIA. OPENING
LOCKNUT FOR
SETTING DIRECTION
(4) COVER SCREWS
(2) 3/4" NPT HOLES
INPUT
RAMP-UP JUMPER
ENABLE
OUTPUT VOLUME CONTROL
PAGING VOLUME ADJUST
PAGING INPUT
INPUT TERMINALS
1
2
RTN RTN
4
3
DISABLE
INPUT 1 TIMING JUMPER
INSTALL FOR 3 MINUTE TIME OUT
REMOVE TO FOLLOW CLOSURE
TONE SELECTION SWITCHES
1
INPUT
2
3
INPUT
4
INPUT
BATTERY
BACKUP
OPTION
SPEAKER AUDIO
+
-
FROM +48 VDC
POWER SUPPLY
OPTIONAL
1
2
DIGITAL VOICE MODULES
INCREASE
INCREASE