(3) .157 DIA HOLES

SPACED EQUALLY ON

A 3.94" OR 100.076 MM

DIA BOLT CIRCLE.

WHT/VIO - ScanLock

ORANGE - Amber Warning LEDs

Mounting

Gasket

10-24 x 5/8 PPHMS

Mounting Screws

(3 Places)

5A

5A

1A

1A

BLUE - Blue Warning LEDs

VIOLET - Low Power

BLACK - Ground

GREY - SYNC (to GREY wire of other SYNC device)

Mounting Pattern

BLUE

BLUE

BLUE

AMBER

(+)

12V

Battery

(-)

Operation
Scan-Lock™ (White/Violet):

To use ScanLock, the warning color to be changed (Blue or Amber) 
must be active. Pattern changes made to the active color do not effect 
the pattern of the inactive color:

TO CHANGE PATTERNS: 

To cycle forward to the next available pattern

 

apply +VBAT to the 

WHT/VIO 

wire for less than 1 second and release. 

To 

cycle back to the previous pattern

 apply +VBAT to the 

WHT/VIO 

wire for 

more than 1 second and release.

TO CHANGE THE DEFAULT PATTERN: 

When the desired pattern is 

displayed, allow it to run for more than 5 seconds. The beacon will now 
display this pattern when initially activated.

TO RESTORE THE FACTORY DEFAULT PATTERN: 

With the power to the 

beacon off, apply +VBAT to the 

WHT/VIO 

wire. Now turn power to the 

beacon on. The factory default pattern should now be displayed.

A normally open momentary switch is best suited for Scan-Lock™
operation.

Flash Patterns:
1.

DoubleFlash Phase 1

2.

DoubleFlash Phase 2

3.

SingleFlash Phase 1

4.

SingleFlash Phase 2

SYNC (Grey):

The  GREY  wire is  used to synchronize the  flash  patterns of other  SYNC-
capable devices. Cap this wire if it is not used.

Phase Operation:

Phase 1 flashes 

simultaneously

 with Phase 1

Phase 2 flashes

 simultaneously

 with Phase 2

Phase 1 

alternates 

with Phase 2

Low Power (Violet):

Applying  +12VDC  to  the  VIO  wire  activates  Low  Power  Mode.  Normal
power is restored when +12VDC is removed.

 Note that Low Power Mode

is for Blue LEDs only.

IMPORTANT:  It  is  the  responsibility  of  the  installation  technician  to
make sure that  the installation and  operation of this  product will not
interfere with or compromise the operation or efficiency of any vehicle
equipment! Permanent mounting of this product will require drilling. It
is  absolutely  necessary  to  make  sure  that  no  other  vehicle
components could be damaged by this process. Check both sides of
the  mounting  surface  before  starting.  If  damage  is  likely,  select  a
different mounting location.

WARNING!  All  customer  supplied  wires  that  connect  to  the  positive
terminal  of  the  battery  must  be  sized  to  supply  at  least  125%  of  the
maximum  operating  current  and  FUSED  at  the  battery  to  carry  the
load. DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!

CAUTION! DO NOT LOOK DIRECTLY AT THESE LED’S WHILE THEY ARE ON.

MOMENTARY BLINDNESS AND/OR EYE DAMAGE COULD RESULT!

I M P O R TA N T W A R N I N G !

Mounting:

1. Provisions  for  mounting  this  beacon  to  a  flat

surface  have  been  provided.  As  shown  at  left,
locations  for  three  (3)  mounting  holes  can  be
found  on  the  underside  of  the  beacon’s  base.
These areas may be tapped as needed.

2. Use  the  information  provided  to  create  a  drilling

template. If a wire passage hole is drilled though
the mounting surface, be sure to de-burr the hole
and install an appropriately sized grommet.

3. Remove  the  protective  backing  from  the

mounting gasket (included). Align the holes in the
gasket with the mounting holes in the base of the
beacon  and  install.  Apply  firm  pressure  to  the
gasket surface to promote adhesion. 

4. Route  the  wires  through  the  wire  passage  hole

and  secure  the  beacon  to  the  mounting  surface
using the mounting screw provided.

5. Complete  the  electrical  connections  using  the

information shown.

IMPORTANT!  Before  returning  the  vehicle  to
active service, visually confirm proper operation
of  this  product  as  well  as  all  vehicle
components/equipment.

Отзывы: