Wheelock ZC-3 Скачать руководство пользователя страница 4

 

 
 

FIGURE 5. 

CONNECTION TO 600 OHM AUDIO PAGE PORT 

 
 
 
WIRING:  See Figure 4. 
 

Make sure the 24VDC Power Supply is disconnected from the 115VAC power source. 

Connect Tip and Ring from telephone system to TB1, terminals 2 and 1 respectively. 

For Zone 1, connect Speaker Amplifiers, Paging Amplifier, or Wheelock Talkback Speaker Module Tip and Ring to TB2 terminals 4 and 3 
respectively.  If a Talkback Speaker Module is used, also: 

 

(A)  Connect its TB inhibit (TB1 terminal 6) to the required ZC-3 zone INH (terminal 13, 14, or 15). 

 

(B)  If Talkback Module and ZC-3 use separate power supplies, then also connect Talkback Module's GND (TB1 terminal 5) to ZC-3's "A"   GND 
(TB1 terminal 4). 

Connect Zone 1 background music source to TB2, terminals 1 and 2.  Background music may be connected to any or all zones. 

Zones 2 and 3 hook up in a similar fashion. 

Connect the "A" battery power supply positive (+) and negative (-) to TB1, terminals 4 and 3 respectively.  Connect the "B" battery power supply 
positive (+) and negative (-) to TB1, terminals 6 and 5 respectively.  One Wheelock RPS-2406 Power Supply ("A" battery) can be used for both "A" 
and "B" battery. 

Recheck all wiring. 

Connect the power supply to the 115VAC power source. 

Test the system using the following operation instructions. 

 
 
OPERATION: 
 

Pick up the telephone handset and press the CO line button (EKSU, KSU), or number assigned to paging (PABX), to access the CO port to which 
ZC-3 has been connected). 

To initiate a zone page, dial "1", "2", or "3" (on the telephone's touchtone keypad) to select zone 1, 2 or 3 respectively. 

To initiate an All-Call page, dial "0" (on the telephone's touchtone keypad). 

Sequential selections can be made between zones, from zones to All-Call, or from All-Call to zones by simply dialing the next zone or All-Call.  
Sequential selections can be made in any order.  It is not necessary to "hang-up" between selections. 

A zone page will mute background music only in the zone selected. 

All-Call will mute background music throughout the system. 

At the conclusion of page (i.e., phone "hangs-up", or another selection is made), the muted background music will automatically be restored. 

When any page is initiated, an alert tone is heard both in the telephone receiver, and at all selected speakers. 

 
 
VOLUME ADJUSTMENTS: 
 

First adjust volume controls on Speaker Amplifiers and Talkback Speaker Modules for required paging volume.  (If paging amplifiers are used with 
conventional speakers equipped with line matching transformers, then refer to the Paging Amplifier's instructions for volume adjustments). 

Next adjust page alert tone volume (internal adjustment in ZC-3), to required level.  When control is turned fully counter clockwise, page alert tone 
is "OFF". 

Lastly, adjust volume on background music source (if applicable). 

 
 
 
 
 
 

P81414 K 

Sheet 4 of 6 

TROUBLE SHOOTING 
 
 
CONDITION  

CHECK 

NOTE 

 
Check telephone system manufacturer's installation instructions for 
any other audio page port connection considerations. 

Содержание ZC-3

Страница 1: ... is causing the malfunction If the equipment is determined to be malfunctioning its use shall be discontinued until the problem has been corrected APPLICATION INFORMATION WARNING ANY MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM WHEELOCK MANUALS OR OTHER DOCUMENTS DESCRIBING THE PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS OR FOR ANY OTHER USE INCLUDING DESCRIPTION OF THE PRODUCT S APPL...

Страница 2: ... Tone Frequency 700 Hz Alert Tone Duration 500 m sec Alert Tone Level 11 dBm Page Input Output Level T R 15 10 dBm Page Input Output Impedance T R 600 Ohms Music Input Output Level 15 10 dBm Music Input Output Impedance 600 Ohms Operating Temperature 0 55 C Operating Humidity TO 85 RH Zone Control Access PRESS CO LINE BUTTON OR TOUCH DIAL NUMBER ASSIGNED TO PAGE Page Zone 1 Dial 1 Page Zone 2 Dial...

Страница 3: ... SIMPLIFIED SCHEMATIC AND CONNECTION DIAGRAM Connect only if Wheelock TBM 101 or TBH 104 Talkback Modules are used P81414 K Sheet 3 of 6 The ZC 3 can be connected to an audio page port only if the audio page port provides A A 600 OHM low power audio output B Transmission of DTMF touchtones C A dry contact closure that closes when the port is selected and opens when the paging telephone hangs up ...

Страница 4: ...ccess the CO port to which ZC 3 has been connected To initiate a zone page dial 1 2 or 3 on the telephone s touchtone keypad to select zone 1 2 or 3 respectively To initiate an All Call page dial 0 on the telephone s touchtone keypad Sequential selections can be made between zones from zones to All Call or from All Call to zones by simply dialing the next zone or All Call Sequential selections can...

Страница 5: ...t and R out and if necessary also at speaker amps input 4 The alert tone is too high or too low 1 Set the alert Tone Volume to the desired level 5 Talkback does not function properly 1 If ZC 3 and TBM 101 or TBH 104 use separate power supplies then check to insure there is a common GND connection between ZC 3 and TBM 101 or TBH 104 2 TBM 101 or TBH 104 inhibit INH terminal must be connected to the...

Страница 6: ...MEET ANY OTHER STANDARD OF PERFORMANCE OR THAT THE FUNCTIONS OR PERFORMANCE OF THE SOFTWARE WILL MEET THE USER S REQUIREMENTS WHEELOCK SHALL NOT BE LIABLE FOR ANY DELAYS BREAKDOWNS INTERRUPTIONS LOSS DESTRUCTION ALTERATION OR OTHER PROBLEMS IN THE USE OF A PRODUCT ARISING OUT OF OR CAUSED BY THE SOFTWARE THE LIABILITY OF WHEELOCK ARISING OUT OF THE SUPPLYING OF A PRODUCT OR ITS USE WHETHER ON WARR...