CAUTION

:  The installation of this equipment should only be undertaken by qualified personnel. 

The Load Number (LN) assigned to each terminal appliance denotes the percentage of the total load to be connected to a 
telephone loop that is used by the appliance to prevent overloading.  The termination on a loop may consist of any 
combination of appliances subject only to the requirement that the total of the Load Numbers of all the appliances does not 
exceed 100. 

Load Number for RX-1419 = 18 

 

CAUTION:

  These appliances are not intended for use in hazardous locations as defined by the National Electrical Code (NEC) 

and by the National Fire Protection Association (NFPA). 
 
 

SPECIFICATIONS: 
 

 

Table 1:  Relay Components 

Contact Ratings 

Model 

Number 

Operating 

Voltages 

Current 

Draw 

 

Ren 

Current Voltage 

39-150VAC, 20-30Hz 

9mA 

0.6 

5A 

115VAC, 60Hz 

18-48VDC 11mA 

----- 

2A 

230VAC, 

60Hz 

 

RX-1419 

30-48VAC 20mA 

----- 

0.5A 

115VAC 

 

 
REPLACEMENT 
 

Mounting into the 163 (Note:  the 163 is no longer available) 

 
 

Figure 1:  Assembly Diagram

 

 

ASSEMBLY DIAGRAM

SIGNAL/GRILLE 

ASSEMBLY

BACKBOX

ASSEMBLY

RINGING RELAY

TELEPHONE LINE

(MODULAR PLUG OR LUGS)

   115 VAC

POWER OUTLET

GROUND

SCREW

   RINGING RELAY

(SEE EXPLODED VIEW)

FROM SIGNAL\GRILLE ASSEMBLY

 

 
 
 
 
 
 

Slide the RX-1419 into                               
the mounting bracket                             
inside the 163 

 
 
 