Wheeler-Rex 29201 Скачать руководство пользователя страница 2

Operating Instructions  

Model 29200 and 29201 

Hydrostatic Test Pump 

 

Siphon Method  
   

Use a clean water source

 

 
     1.   Fill the water line to be tested. 
     2.   Fill the intake hose (hose is not supplied, require PN 34550) with water,  then quickly 
 

place the hose into a bucket and start pumping handle. (The unit is self-priming once 

 

primed.) Continue to pump until you see the water coming out of the outlet, with little or 

 

no air mixed with it. 

     3.   Connect the output hose to the water line. Continue on with steps 5 through 7 above. 
 
 

Pre-Setting Your Pump 
   

Your pump can be pre-set to a specific pressure easily by adjusting the pressure relief valve. 

1. 

Unscrew (counter clockwise direction) pressure relief valve (D).   (Note: the valve  
assembly will not come out of the casting body).

 

2. 

Add a ball valve (not supplied with pump) to the end of the high pressure hose.

 

3. 

Follow steps 1 through 3 from the ‘Pressure Feed Method’ above.

 

4. 

As water is flowing out of the high pressure hose, turn the ball valve to the off        
position.

 

5. 

Slowly start turning pressure relief valve (in the clockwise direction) by ¼ turn       
increments as you are pumping the handle, until you reach the desired pressure.

 

6. 

Your test pump is now pre-set. This eliminates over-pressurizing the water line (or 
the vessel).

 

A Gauge 

B Handle 

C Ball 

Valve 

Pressure Relief Valve 

Garden Hose Inlet Connection 

F Hose 

Adapter 

Содержание 29201

Страница 1: ... and pressure hose of all air You may have to pump the handle B a few times to get the water to flow out 4 Connect output pressure hose between pump F hose adapter and water line or vessel being tested Water line or test vessel should be pre filled with water before the test pump is attached 5 Purge water line or vessel of all air at the highest point of the system 6 Bring water line or vessel to ...

Страница 2: ...ure easily by adjusting the pressure relief valve 1 Unscrew counter clockwise direction pressure relief valve D Note the valve assembly will not come out of the casting body 2 Add a ball valve not supplied with pump to the end of the high pressure hose 3 Follow steps 1 through 3 from the Pressure Feed Method above 4 As water is flowing out of the high pressure hose turn the ball valve to the off p...

Страница 3: ...Lightly tap the casting body with a wood block Rotate listen for check balls to rattle inside Check O rings for wear and or cracks Replace if necessary with Wheeler Rex rebuild kit PN 29250 Lightly grease each O ring when rebuilding Pump Maintenance Pump 50 50 antifreeze water solution through pump after each use to avoid freezing check balls from sticking Rebuild Kit Wheeler Rex PN 29250 Suction ...

Страница 4: ...29250 Repair Kit Qty 220096 SCREEN RETAINER 1 221413 OVERLOAD SPRING 1 203201 5 16 SS BALL 1 275815 O RING 1 275435 38 SS BALL 2 275917 STRAINER WASHER 1 276806 O RING 1 ...

Страница 5: ...29250 Repair Kit Qty 220096 SCREEN RETAINER 1 221413 OVERLOAD SPRING 1 203201 5 16 SS BALL 1 275815 O RING 1 275435 38 SS BALL 2 275917 STRAINER WASHER 1 276806 O RING 1 ...

Страница 6: ......

Отзывы: