background image

Operating Instructions  

Model 29200 and 29201 

Hydrostatic Test Pump 

060115 

 

Dimension 

15” (38cm) L x 10” (25cm) W x 8” (20cm) H 

Weight 

10.5lbs; 4.8 kg  / 11.5 lbs; 5.3 kg 

Pump Pressure for 29200 

0 - 300psi (21 bar) 

Pump Pressure for 29201 

0 - 1000psi (70 bar) 

Gauge for 29200 

Glycerin filled,  0 - 600psi (40 bar) 

Gauge for 29201 

Glycerin filled, 0-2000psi (138 bar) 

Inlet Connection 

3/4” Female Garden Hose 

Outlet Connection  

9/16 - 18 JICF Male 

Hose Ends 

9/16 - 18 JICF Female Swivel x 1/4” Male NPT 

Discharge Hose 

1/4” ID x 10’ Long 

Pressure Feed Method: (Preferred Method #1) 

  This is typically a residential water source with about 40 to 60 psi 

1.  Connect water supply hose to the garden hose inlet connection (E) on the pump. 
2.  Open valve and turn supply water on. 
3.  Purge the pump and pressure hose of all air. (You may have to pump the handle (B)

a few times to get the water to flow out.) 

4.  Connect output (pressure) hose between pump (F) hose adapter and water line (or 

vessel) being tested. (Water line or test vessel should be pre-filled with water before 
the test pump is attached.) 

5.  Purge water line (or vessel) of all air at the highest point of the system. 

6. 

Bring water line (or vessel) to pressure by quickly pumping handle (B).

 

7. 

Watch the gauge while pumping. As you reach the desired pressure; on the     
downward stroke turn the valve (C) to the ‘off’ position. If pressure drops off, there is 
a leak in the line.

  

 

Gravity Feed Method: (Preferred Method #2) 
 

This method requires a tank with a water outlet at the bottom. The water tank’s outlet  

 

should be level with or above the level of the water inlet connection on the pump. This  

 

allows water to flow naturally into the test pump.  Follow the “Pressure Feed Method” 

 

steps 1 through 7 (listed above)

 

 

 

 
 
 

Содержание 29201

Страница 1: ... and pressure hose of all air You may have to pump the handle B a few times to get the water to flow out 4 Connect output pressure hose between pump F hose adapter and water line or vessel being tested Water line or test vessel should be pre filled with water before the test pump is attached 5 Purge water line or vessel of all air at the highest point of the system 6 Bring water line or vessel to ...

Страница 2: ...ure easily by adjusting the pressure relief valve 1 Unscrew counter clockwise direction pressure relief valve D Note the valve assembly will not come out of the casting body 2 Add a ball valve not supplied with pump to the end of the high pressure hose 3 Follow steps 1 through 3 from the Pressure Feed Method above 4 As water is flowing out of the high pressure hose turn the ball valve to the off p...

Страница 3: ...Lightly tap the casting body with a wood block Rotate listen for check balls to rattle inside Check O rings for wear and or cracks Replace if necessary with Wheeler Rex rebuild kit PN 29250 Lightly grease each O ring when rebuilding Pump Maintenance Pump 50 50 antifreeze water solution through pump after each use to avoid freezing check balls from sticking Rebuild Kit Wheeler Rex PN 29250 Suction ...

Страница 4: ...29250 Repair Kit Qty 220096 SCREEN RETAINER 1 221413 OVERLOAD SPRING 1 203201 5 16 SS BALL 1 275815 O RING 1 275435 38 SS BALL 2 275917 STRAINER WASHER 1 276806 O RING 1 ...

Страница 5: ...29250 Repair Kit Qty 220096 SCREEN RETAINER 1 221413 OVERLOAD SPRING 1 203201 5 16 SS BALL 1 275815 O RING 1 275435 38 SS BALL 2 275917 STRAINER WASHER 1 276806 O RING 1 ...