6. Troubleshooting - Whale iVan Control Panel

Step 1 - Space Heater Lockout

Step 2 - Identify Lockout

Step 3 - Recommended Action

                         Example

Fault type #1 - Inadequate gas supply

1.  Check gas
2.  30mbar LPG
3.  Go to step 4

Fault type #2 - Overheat

1.  Check air vents and ducts are not restricted
2.  Wait 10 mins for heater to cool down
3.  Go to step 4

Fault type #3 - Inadequate supply voltage

10.5 - 15.9V d.c. - 

Heater inoperable under 10.1V

≥ 10.5 / ≤  15.9V d.c.
<  10.5 / >15.9V d.c.
Go to step 4

Fault type #4 - Flue blockage

1.  Check fl ues for blockages
2.  Go to step 4

                         Example

Fault types #5-11 Internal fault

1.  Go to step 4
2.  Call Whale s44 (0)345 9090 911. 

Fault type #15 - Multiple faults

1.  Power off 
2.  Check heater for recurring faults
3.  Power on
4.  Go to step 4

X

-8-

Содержание SL5502

Страница 1: ...Gas Electric Space Heater Recreational Vehicle warm air heater operates using gas and or electric SL5512 SL7512 SL5502 SL7502 Operating Instructions with iVan Control Panel ...

Страница 2: ...ntact Whale Support immediately It is the sole responsibility of the vehicle owner to ensure that the appliance is in a safe operating condition and is operated correctly The unit may be operated only with approved Whale control panels and accessories If the flues have been placed near or directly beneath an opening window the device must be equipped with an automatic shut off device in order to pre...

Страница 3: ...s with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unl...

Страница 4: ...vice is required if this appliance is operated while driving If no safety shut off device has been installed the gas cylinder must be closed when driving To prevent damage to the appliance from spray water such as when cleaning the vehicle do not spray water directly into the exhaust duct combustion intake or on the heater housing and connections 3 These symbols indicate that this appliance is suit...

Страница 5: ... 4 5 Instructions for Use iVan Control Panel Figure 1 Whale iVan Control Panel Overview Figure 2 Space Heater Icon ...

Страница 6: ...c On Gas Off Gas On Fan Off Fan On Off Button Active Off Button Inactive Night Mode 10o C 18o C Off Night Mode 10o C 18o C Active Night Mode Selected Frost Protection Mode 6o C 10o C Off Frost Protection Mode 6o C 10o C Active Frost Protection Mode Selected Increase Temperature Button Decrease Temperature Button Figure 3 Room Heater Control Screen 5 ...

Страница 7: ...Usable Electric Settings 6A 0 75kW 230V a c 10A 1 50kW 230V a c 16A 3 00kW 230V a c 2 Activate Gas Power 3 Activate Electric Setting And Or 6 1 Select Temperature ...

Страница 8: ... 7 4 Setting Timers 5 Activating Timers ...

Страница 9: ... restricted 2 Wait 10 mins for heater to cool down 3 Go to step 4 Fault type 3 Inadequate supply voltage 10 5 15 9V d c Heater inoperable under 10 1V 10 5 15 9V d c 10 5 15 9V d c Go to step 4 Fault type 4 Flue blockage 1 Check flues for blockages 2 Go to step 4 Example Fault types 5 11 Internal fault 1 Go to step 4 2 Call Whale support 44 0 345 9090 911 Fault type 15 Multiple faults 1 Power off 2 C...

Страница 10: ...Step 4 Clear Lockout If problems persist please contact Whale Support on 44 0 345 9090 911 9 ...

Страница 11: ...ding accessories Modifications to the exhaust duct or combustion intake Use of replacement and accessory parts other than original Whale part Failure to follow the installation and operating instructions Use of the appliance for non leisure purposes The heat exchanger must be replaced with a Whale original spare part every 10 years from date of registration See the data label on the heater for the ...

Страница 12: ...the safety objectives of the Low Voltage Directive Please contact Whale if further details are required Richard Bovill Engineering Director Manufactured by Whale 2 Enterprise Road Bangor BT19 7TA Tel 44 0 28 9127 0531 Patents and Trademarks The Whale Space Heater is protected by two pending patents Whale and iVan are registered trademarks of Munster Simms Engineering Ltd Warranty Munster Simms Eng...

Отзывы: