Whale BP2083B Скачать руководство пользователя страница 10

Fig 10 Secure pipework

Ensure that pump installation is thoroughly tested before first use. 

NOTE

- These are all automatic or semi-automatic applications - ensure that isolator

switch is turned on.

BILGE APPLICATION 

Gulper® IC with Strainer IC - Place finger over sensor area to check pump is

activated, remove finger and wait for the pump to stop (45 seconds). 

Fig 11 Testing Strainer IC

This Whale Gulper® IC is designed to only require minimal maintenance.

WARNING

: Before servicing pump, turn off pump and drain water from system.

Annual Checks 

Whale advise that the boat's plumbing system is checked annually for 

leaks and obstructions. Also a pump electrics check is advisable. 

Before inspecting or replacing the diaphragm, disconnect the electrical 

supply. 

Optimal Performance

Ensure this product is clear of debris 

IF THE PUMP IS NOT OPERATING AS EXPECTED:-

Loosen the hose clips to release the pump from plumbing. 

Unscrew the Ezi-clamp clamping ring to release the pump head - see Fig 

3 - This will release the pump head, and allow easy access to the valves 

& diaphragm. 

The diaphragm and valves should be checked for any excessive wear, 

damage or cracks, and should be replaced if necessary (service kit 

AK2050 - replacement pump head).

13. INSTRUCTIONS FOR USE

14. MAINTENANCE

All manuals and user guides at all-guides.com

Содержание BP2083B

Страница 1: ...8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with 2m 6ft cable SI8224B Bulk Strainer...

Страница 2: ...rimary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilge Pump INSTALLATION USE...

Страница 3: ...p Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strainer IC Horizontal easil...

Страница 4: ...ONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent Control Technology At...

Страница 5: ...Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid accumulation of water due...

Страница 6: ...a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 ii Mounting Instructions Gulper IC G...

Страница 7: ...ot over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig 4 NOTE In order to secu...

Страница 8: ...t reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor performance and potential m...

Страница 9: ...C SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework to connect to the pump S...

Страница 10: ...at the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the electrical supply Opti...

Страница 11: ...he inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the isolator switch is on and working C...

Страница 12: ...intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit Part number AK2050 Rest...

Страница 13: ...ectromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed for use within certain...

Отзывы: