background image

6

Warning

!

Cleaning products that contain abrasives can damage the pedicure spa. Use only non-abrasive
products to clean your spa.

Always check with your state board for required cleaning and disinfecting procedures. It is extremely important to clean and 
disinfect your pedicure spa after each pedicure, after the last pedicure of the day, and once a week for overnight cleaning. 
Regular cleaning will help keep your pedicure spa in good working condition. Proper and continuous cleaning will kill harmful 
bacteria and germs that can cause infection. To clean your pedicure spa equipped with pipeless technology, follow these 
easy steps:
After use upon each patron, each pipeless pedicure spa shall be cleaned and disinfected in the following manner:
(1) All water shall be drained from the spa basin.
(2) Remove 2 piece inlet housing & impeller.
(3) Scrub all visible residue from the inlet housing, impeller, inside walls of the basin, and/or other components and the    
     areas behind or under each with a clean brush and liquid soap (labelled as such on soap product) and water. Rinse with 
     clean water.
(4) Re-insert the properly cleaned inlet housing & impeller.
(5) Refill the basin with clean water and circulate the correct amount (read the label for mixing instructions) of the EPA-
     registered hospital-liquid disinfectant which the label claims is a bactericide, fungicide, and virucide, through the basin for at 
     least 10 minutes.
(6) Drain, rinse and wipe the basin dry with a clean paper towel.
(7) Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of
      each cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was done after a 
      client.

At the end of every day and after performing the procedures provided in subsection (b) (1 through 6) and after the
last client, each pipeless pedicure spa shall be cleaned and disinfected in the following manner:

(1) Fill the basin with warm water and detergent (labelled as such on detergent product) and circulate the detergent through 
     the spa system for at least 10 minutes.
(2) Drain the detergent solution and rinse the basin.
(3) Refill the basin with clean water and circulate the correct amount (read the label for mixing instructions)
      of the EPA-registered hospital-liquid disinfectant which the label claims is a bactericide, fungicide, and virucide, through the 
      basin for at least 10 minutes.
(4) Drain, rinse and wipe the basin dry with a clean paper towel.
(5) Allow the basin to dry completely.
(6) Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of
     each cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was done at the end
     of the day.

At least once each week, after completing the procedures provided in subsection (c) (1 through 3), and the
disinfectant solution in each pipe-free pedicure spa shall not be drained and the following procedures shall be
followed:

(1) The unit shall be turned off and the disinfecting solution shall be left in the unit undisturbed for 6 to 10 hours.
(2) After the disinfectant solution has been sitting between 6 to 10 hours, drain, rinse and wipe the basin dry with a clean 
paper towel.
(3) Record this procedure in the pedicure-cleaning log. The log shall contain the date and time of each cleaning, initials of the
     person who completed the procedure, and shall indicate that the cleaning was done weekly. The pedicure-cleaning log shall 
     be made available upon request by either a patron or a state board representative. A violation of this section may result in an 
     administrative fine and/or disciplinary action.

PIPELESS JET CLEANING

Pure-Flo Pipeless Spa Cleaning and Disinfecting Procedure

 3

!

Warning

Содержание ALDEN 75i

Страница 1: ...IS MANUAL FOR FUTURE REFERENCE OWNER MANUAL ALDEN CRYSTAL 2016 Whale Spa All rights reserved Design and Specifications are subject to change without notice OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUT...

Страница 2: ...Limited Warranty Safety and Precautions Pipeless Jet Cleaning Pedicure Components Clearances Installations Jet Removal Plumbing Connections 3 4 5 6 7 8 9 10 11 12 Table of Contents Owner Manual...

Страница 3: ...nsed professional in accordance with Whale Spa s installation instructions the proper use of cleaning and sanitizing solutions in accordance with the instruction labels provided by Whale Spa Repeated...

Страница 4: ...diately discontinue the use of the pedicure spa Your client s massage and pedicure spa experience should be pleasant and comfortable Warning SAFETY PRECAUTION 1 The Whale Spa pedicure chairs herein re...

Страница 5: ...ments for Backflow Protection Devices and Systems in Plumbing Fixture Fittings is applicable to plumbing fixture fittings with outlets not protected by an air gap Included in the possible range of app...

Страница 6: ...es provided in subsection b 1 through 6 and after the last client each pipeless pedicure spa shall be cleaned and disinfected in the following manner 1 Fill the basin with warm water and detergent lab...

Страница 7: ...ushion 9 Adjustable Footrest 10 Jet Control 11 Drain Control 12 Drain 13 Pull out Hand Spray 14 Jet 9 10 4 1 Hot Cold Water Control 2 Glass Bowl 3 Wooden Armrest 4 Flip out Tray with Cup Holder 5 Chai...

Страница 8: ...8 PEDICURE COMPONENTS SEAT OPERATION SPA DIMENSION Armrest can be raised up down Reclining Sliding 53 52 16 30 5 56 31...

Страница 9: ...9...

Страница 10: ...10...

Страница 11: ...nts must be assembled in sequence of order to avoid malfunction Please call manufacturer for repair or replacement Jet Unit Jet base secured on bowl wall 8 Remove Magnetic Jet from jet base To install...

Страница 12: ...12 56 56...

Отзывы: