![wh EMP 500 v7 /CLB Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/wh/emp-500-v7-clb/emp-500-v7-clb_technical-manual_967078059.webp)
WH Münzprüfer Dietmar Trenner GmbH, Germany
Technical Manual EMP 500 v7 /CLB
version 2.7
EMP 500 v7 /CLB
subject to technical modification
page 59/62
Fig. 25 Connecting diagram Totalizer EMP 500 v7 /CLB with 1206
Fig. 36 Connecting diagram Stepper EMP 500 v7 /CLB with interface 0106
price 1 (normally open), white
inventory (normally open), brown
PC815
1
2
3
4
8
PC815
1
2
3
4
3
7
4
1
5
+
-
~
~
1
2
4
3
2
1
4
3
2
6
GND
GND
GND
GND
main blocking, orange
GND
12 to 24V AC/DC, black
35 V DC, 30 mA
12 to 24V AC/DC, black
*) approx. 100 msec. during coin acceptance
power supply, 12 to
24 V AC/DC,
0,6 W / (4,5 W *)
35 V DC, 30 mA
main blocking, orange
EMP 500.1206
control
I > 0,5 mA AC/DC
inventory (normally open), yellow
price 1 (normally open), red
price 1, blue
inventory, grey
60 V AC, 600 mA
S26MD01
1
2
3
4
5
6
8
4
+
-
~
~
1
2
4
3
2
6
3
5
2
1
4
3
8
1
7
S26MD01
1
2
3
4
5
6
8
GND
GND
GND
GND
GND
main blocking, orange
main blocking, orange
12 to 24V AC/DC, black
12 to 24V AC/DC, black
*) approx. 100 msec. during coin acceptance
I > 0,5 mA AC/DC
EMP 500.0106
control
power supply, 12 to
24 V AC/DC,
0,6 W / (4,5 W *)
price 1, green
inventory, violet
60 V AC, 600 mA