Electronic Current Limiting

In the event that the output current exceeds the maximum rating for the WF-9500 Series 

Power Center converter, the output current will remain constant but the output voltage will 

begin to drop. If this occurs, the unit will recover once loads are reduced.    

Short-Circuit Protection

Should a short circuit occur in the RV, the WF-9500 Series Power Center converter will drop 

the voltage output to zero volts. If the short-circuit condition is removed and no other fault 

conditions are detected, the converter will resume normal operation. However, short-circuit 

conditions are 

dangerous

, and an RV will require inspection by a qualified service 

technician.

 

 

CIRCUIT PROTECTION
WF-9500MBA Series Main Board Assembly Fuses and Breakers

Reverse Battery Protection

The WF-9500MBA Series Main Board Assembly will charge the 12-volt House battery if 

installed.  A battery DOES NOT have to be installed for WF-9500MBA Series Main Board 

Assembly to oper-ate. When a battery is installed, two reverse polarity fuses protect the MBA 

circuitry. The fuses are located along the left-center edge of the DC fuse board below the 

VCC+ lug. Refer to Figure 1 below. This feature prevents permanent damage to the MBA 

from a battery connected into the circuit backwards. In addition to protecting the MBA, the 

reverse polarity fuses are the main connection between the MBA and the DC fuse board.

The fuse values and quantity vary depending on which WF-9500MBA Series Main Board 

Assembly you have. Refer to the table below.

•   WF-9540MBA – 25A (2)

•   WF-9560MBA – 35A (2)

•   WF-9580MBA – 30A (3)

The circuit fuses and the Reverse Battery Protection fuses should be replaced with ATC or 

ATO automotive type fuses such as:

•   Littelfuse type 257 

•   Bussmann type ATC

 

 

 

 

 

 

 

 

4

Содержание WF-9500MBA Series

Страница 1: ...ION 877 294 8997 Warranty warranty wfcoelectronics com Fax 574 294 8698 www wfcoelectronics com Power PROs Technical Support 877 294 8997 WF 9500MBA Series WF 9540MBA WF 9560MBA WF 9580MBA The Power Center model number is located on the front panel label next to the breakers ...

Страница 2: ...ION Reverse Battery Protection 4 OPERATIONAL FEATURES Three Stage Smart Charging 5 TROUBLESHOOTING INSTRUCTIONS Converter Output Voltage 6 Reverse Polarity Fuses 6 Troubleshooting Flow Chart 7 Replacing the MBA 7 GENERAL COMPLIANCE INFORMATION Agency Listings 9 INSTALLATION INSTRUCTIONS Mounting the MBA 9 WARRANTY INFORMATION 10 SPECIFICATIONS 11 TABLE OF C ONTENTS 2 ...

Страница 3: ...al load increases and decreases fan speed as the load decreases Unlike traditional temperature controlled fans the load controlled fan provides better component cooling by avoiding temperature spikes which can lead to premature component failure Over Temperature Protection If the internal temperature of the converter exceeds a critical point it will shut down This protects the unit from excessive ...

Страница 4: ...tery Protection The WF 9500MBA Series Main Board Assembly will charge the 12 volt House battery if installed A battery DOES NOT have to be installed for WF 9500MBA Series Main Board Assembly to oper ate When a battery is installed two reverse polarity fuses protect the MBA circuitry The fuses are located along the left center edge of the DC fuse board below the VCC lug Refer to Figure 1 below This...

Страница 5: ...y to hold the converter s maxi mum output current level the amperage rating without exceeding it If the output current reaches its maximum normally caused by a discharged battery this will cause the converter to go into Bulk Mode which means the target output voltage will change to 14 4 volts and a timer will start Although the converter is outputting 14 4 volts you will not be able to read that o...

Страница 6: ...he converter is functioning properly If the converter output voltage at the battery reads 0 0 VDC or if the battery is not charging check for an open inline fuse in the battery wire circuit One may have been installed by the RV manufacturer Also check for loose wiring connections DC Reverse Polarity Fuses If there is no DC output coming from the WF 9500MBA Series Main Board Assembly converter sect...

Страница 7: ...ound This alarm will continue to sound until the AC wires are connected correctly If the above checks have been made but the converter output still reads 0 0 VDC the converter is not functioning properly Contact the Arterra Distribution Power PROs at 1 877 294 8997 Should it be determined that the WF 9500MBA Series Main Board Assembly needs to be replaced removal of the Main Board Assembly Is a si...

Страница 8: ...k wire from the breaker NOTE This wire has a metal pin that is inserted into the breaker with a pigtail wire added to it If the pigtail wire is connected to another wire disconnect that wire from the pigtail 5 Remove the converter white wire from the neutral bus bar 6 Remove the converter green wire from the ground bus bar 7 In the converter compartment remove the two screws at the front of the MB...

Страница 9: ... commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense INS...

Страница 10: ...ot limited to inconvenience loss of service loss of revenue loss or damage to personal property cost of all services performed in removing or replacing the WFCO product Specifications are subject to change without notice or obligation Any WFCO Electronics products sold through unauthorized Internet sources Example eBay will be excluded from all warranty coverage offered by Arterra Distribution WFC...

Страница 11: ...11 ...

Страница 12: ...W F C O E L E C T R O N I C S C O M ...

Отзывы: